Products
Oscilloscopes

HDO9404-MS

4 GHz, 10-bit, 40 GS/s, 4+16 Ch, 64 Mpts/Ch HD Mixed Signal Oscilloscope w/ 15.4" WXGA Color Display


HDO9104   (1 GHz Bandwidth, 10-bit, 4 Input Channels, 40 GS/s on 2 Ch Sample Rate)
Quick Specs
Bandwidth1 GHz
Sample Rate20 GS/s on 4 Ch
40 GS/s on 2 Ch
Maximum Acquisition Memory128 Mpts (2 Ch operation)
Input Channels4
Vertical Resolution10 bit
HDO9204   (2 GHz Bandwidth, 10-bit, 4 Input Channels, 40 GS/s on 2 Ch Sample Rate)
Quick Specs
Bandwidth2 GHz
Sample Rate20 GS/s on 4 Ch
40 GS/s on 2 Ch
Maximum Acquisition Memory128 Mpts (2 Ch operation)
Input Channels4
Vertical Resolution10 bit
HDO9304   (3 GHz Bandwidth, 10-bit, 4 Input Channels, 40 GS/s on 2 Ch Sample Rate)
Quick Specs
Bandwidth3 GHz
Sample Rate20 GS/s on 4 Ch
40 GS/s on 2 Ch
Maximum Acquisition Memory128 Mpts (2 Ch operation)
Input Channels4
Vertical Resolution10 bit
HDO9404   (4 GHz Bandwidth, 10-bit, 4 Input Channels, 40 GS/s on 2 Ch Sample Rate)
Quick Specs
Bandwidth4 GHz
Sample Rate20 GS/s on 4 Ch
40 GS/s on 2 Ch
Maximum Acquisition Memory128 Mpts (2 Ch operation)
Input Channels4
Vertical Resolution10 bit
HDO9104-MS   (1 GHz Bandwidth, 10-bit, 4+16 Input Channels, 40 GS/s on 2 Ch Sample Rate)
Quick Specs
Bandwidth1 GHz
Sample Rate20 GS/s on 4 Ch
40 GS/s on 2 Ch
Maximum Acquisition Memory128 Mpts (2 Ch operation)
Input Channels4
Vertical Resolution10 bit
HDO9204-MS   (2 GHz Bandwidth, 10-bit, 4+16 Input Channels, 40 GS/s on 2 Ch Sample Rate)
Quick Specs
Bandwidth2 GHz
Sample Rate20 GS/s on 4 Ch
40 GS/s on 2 Ch
Maximum Acquisition Memory128 Mpts (2 Ch operation)
Input Channels4
Vertical Resolution10 bit
HDO9304-MS   (3 GHz Bandwidth, 10-bit, 4+16 Input Channels, 40 GS/s on 2 Ch Sample Rate)
Quick Specs
Bandwidth3 GHz
Sample Rate20 GS/s on 4 Ch
40 GS/s on 2 Ch
Maximum Acquisition Memory128 Mpts (2 Ch operation)
Input Channels4
Vertical Resolution10 bit
HDO9404-MS   (4 GHz Bandwidth, 10-bit, 4+16 Input Channels, 40 GS/s on 2 Ch Sample Rate)
Quick Specs
Bandwidth4 GHz
Sample Rate20 GS/s on 4 Ch
40 GS/s on 2 Ch
Maximum Acquisition Memory128 Mpts (2 Ch operation)
Input Channels4
Vertical Resolution10 bit
Check up to three models.
Key Features
  • 10 bit resolution; up to 13.8 bits with Optimized Filtering
  • 1 GHz- 4 GHz bandwidths
  • Up to 40 GS/s sample rate
  • 15.4" capacitive touch screen
  • MAUI with OneTouch
    • Designed for touch
    • Built for simplicity
    • Made to solve
  • Advanced Tools
    • Jitter and Timing Analysis Capabilities
    • WaveScan – Search and Find
    • LabNotebook Documentation and Report Generation
    • History Mode – Waveform Playback
  • Optional Software Packages
    • Advanced Customization
    • Digital Filtering
    • Spectrum Analysis
    • Device and Switching Power Supply Analysis
    • Comprehensive set of serial data analysis, debug, validation and compliance tools
  • 16 digital channels with 1.25 GS/s
    • Analog and Digital Cross-Pattern Triggering
    • Digital Pattern Search and Find
    • Analog and Digital Timing Measurements
    • Logic Gate Emulation
    • Activity Indicators


HD1024 High Definition Technology

HD1024 high definition technology enables 10 bits of vertical resolution with 4 GHz bandwidth. The HDO9000 automatically and dynamically determines the best ADC configuration under each specific measurement condition to always provide the optimal resolution.

Dynamic ADC Reconfiguration

HD1024 technology enables dynamic reconfiguration of the ADC to achieve 10 bits of vertical resolution. By automatically determining the best ADC configuration under each specific measurement condition, the HDO9000 always provides the optimal resolution.

Optimized Filtering

HD1024 high definition technology makes use of optimized filtering to provide additional resolution beyond 10-bits; extending up to 13.8 bits. When operating in low sample rate conditions, an anti-aliasing filter is automatically applied to reduce excess out-of-band noise. Additionally, resolution can be improved by applying a manual bandwidth limit on an individual channel.

Superior User Experience

The HDO9000 and MAUI with OneTouch allows users to perform all common operations with a single touch of the display, optimizing for convenience and efficiency. Meanwhile, the 15.4” high resolution capacitive touch screen’s bright display and quick responsiveness further enhances the inherent efficiency and intuitiveness of MAUI with OneTouch.

MAUI with OneTouch

The HDO9000 and MAUI with OneTouch sets the standard for oscilloscope user experience by providing the most unique touch features on any oscilloscope. Common gestures are used to instinctively interact with the oscilloscope and dramatically reduce setup time. Convenience and efficiency are optimized - all common operations can be performed with one touch and do not require opening and closing of pop-up dialogs or menus.

Powerful, Deep Toolbox

The standard collection of math, measurement, debug, and documentation tools provides unsurpassed analysis capabilities. Application-specific packages enable streamlined debugging for common design/validation scenarios. The advanced customization option (XDEV) enables user-defined parameters and math functions providing unique and limitless analysis capability.

Exceptional Serial Data Tools

A wide a variety of application packages are available to meet all serial data test challenges, ranging from automated compliance packages to flexible debug toolkits. A suite of protocol specific measurement and eye diagram packages are available to complement the industry’s most intuitive trigger and decode packages.

Integrated Mixed Signal Capabilities

The HDO9000 High Definition Oscilloscopes offer powerful mixed signal solutions that combine high definition analog channels with the flexibility of digital inputs. The HDO9000-MS models are equipped with an integrated 16 digital channels and a 1.25 GS/s sampling rate which creates an all-in-one debug machine.

High-speed Digital Analyzer

For applications demanding even higher-performance mixed-signal acquisition capabilities, the HDA125 High-speed Digital Analyzer can be easily added to the HDO9000. With 12.5 GS/s digital sampling rate on 18 input channels and the revolutionary QuickLink probing solution, validation of challenging interfaces such as DDR memory has never been simpler or more comprehensive.

Serial Trigger, Decode, Measure/Graph, and Eye Diagrams

Isolate events using the serial bus trigger and view color-coded protocol information on top of analog or digital waveforms. Timing and bus measurements allow quick and easy characterization of a serial data system. Serial (digital) data can be extracted and graphed to monitor system performance over time. Identify physical layer anomalies with eye diagram mask testing and mask failure locator.

LabNotebook

LabNotebook automatically saves all displayed waveforms, oscilloscope setup file, and a screen with a single button press, eliminating the need to navigate multiple menus to save all these files independently. Report files can be annotated and shared with colleagues to fully document all results.

Q-Scape Multi-tab Display Architecture

Unique Q-Scape multitab display architecture speeds your understanding of your design with 4x the display area. Acquired or calculated waveforms can be located on any of four different “tabbed” oscilloscope grid displays, with individually selectable grid styles available for each tab. Quickly move waveforms to different tabs through drag-and-drop.

Jitter and Timing Analysis Option

JITKIT makes it simple and easy to understand the basic system jitter performance of clock signals and clock-data activities, including period, half period, cycle-cycle, skew, amplitude, differential voltage crossing, slew rate, and a wide variety of other common jitter measurements.

XDEV Advanced Customization Option

With the XDEV option, third party programs can be completely integrated into the oscilloscope’s processing stream. Create customized math functions and parameters using C/C++, MATLAB, Excel, JScript or Visual Basic without ever leaving the oscilloscope application - and view the results directly on the oscilloscope, in real-time.

Vertical - Analog Channels

Analog Bandwidth (Max) 4 GHz
Analog Bandwidth @ 50 Ω (-3 dB) (ProBus Input) 4 GHz
(≥ 5 mV/div)
Analog Bandwidth @ 1 MΩ (-3 dB) (ProBus Input) 1 GHz (typical)
Rise Time (10-90%, 50 Ω) 100 ps (typical)
Rise Time (20-80%, 50 Ω) 75 ps (typical)
Input Channels 4
Vertical Resolution 10 bits, up to 13.8 bits with Optimized Filtering
Effective Number of Bits (ENOB) 6.8 bits (typical)
Vertical Noise Floor (1 mV/div) 160 uV
Vertical Noise Floor (2 mV/div) 160 uV
Vertical Noise Floor (5 mV/div) 317 uV
Vertical Noise Floor (10 mV/div) 342 uV
Vertical Noise Floor (50 mV/div) 859 uV
Vertical Noise Floor (100 mV/div) 1.48 mV
Vertical Noise Floor (200 mV/div) 5.15 mV
Vertical Noise Floor (500 mV/div) 8.37 mV
Vertical Noise Floor (1 V/div) 14.9 mV
Sensitivity 50 Ω: 1 mV-1 V/div, fully variable;
1 MΩ: 1 mV-10 V/div, fully variable
DC Vertical Gain Accuracy (Gain Component of DC Accuracy) ±(1%) F.S, offset at 0 V
Channel-Channel Isolation DC -2.5 GHz: 40 dB (>100:1),
2.5 GHz to rated BW: 31.6 dB (>30:1)
(For any two ProBus input channels, same v/div settings, typical)
Offset Range 50 Ω
BWL≤1 GHz
±1.6 V @ 1 mV - 4.95 mV/div
±4 V @ 5 mV - 9.9 mV/div
±8 V @ 10 mV - 19.8 mV/div
±10 V @ 20 mV - 1V/div
BWL>1GHz
±1.4V @ 5 mV - 100 mV/div
±10V @ 102 mV - 1 V/div

1 MΩ
±1.6 V @ 1 mV - 4.95 mV/div
±4 V @ 5 mV - 9.9 mV/div
±8 V @ 10 mV - 19.8 mV/div
±16 V @ 20 mV - 100 mV/div
±80 V @ 102 mV - 1.0 V/div
±160 V @ 1.02 V - 10 V/div
DC Vertical Offset Accuracy ±(1.5% of offset setting +1% of full scale + 1 mV) (test limit)
Maximum Input Voltage 50 Ω: 5V RMS ± 10V peak
1 MΩ: 400 V max. (DC + peak AC < 10 kHz)
Input Coupling 1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Input Impedance 50 Ω+/-2% or 1 MΩ||17pF, 10 MΩ || 9.5 pF with supplied Probe
Bandwidth Limiters 20MHz, 200MHz, 500 MHz, 1GHz, 2 GHz, 3 GHz
 

Horizontal - Analog Channels

Timebases Internal timebase common to 4 input channels; an external clock may be applied at the EXT input
Time/Division Range HD1024 on: 20 ps/div - 500 µs/div
HD1024 off: 20 ps/div - 6.4 ks/div;
RIS available at ≤ 10 ns/div;
Roll Mode available at ≥ 100 ms/div and ≤ 5 MS/s
Clock Accuracy <=1.5 ppm +(aging of 0.5 ppm/yr from last calibration)
Channel-Channel Deskew Range ±9 x time/div. setting, each channel
External Timebase Reference (Input) 10MHz +/-25ppm into 50 ohms
External Timebase Reference (Output) 10MHz, 3.5 dBm +/-1dBm, syncronized to reference being used (internal or external reference)
External Clock DC to 100 MHz; (50 Ω/1 MΩ), EXT BNC input, Minimum rise time and amplitude requirements apply at low frequencies.
 

Acquisition - Analog Channels

Sample Rate (Single-shot) 20 GS/s on 4 Ch
40 GS/s on 2 Ch
Sample Rate (Repetitive) 200 GS/s for repetitive signals (20 ps/div to 10 ns/div)
Memory Length (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
64M / 128M / 128M
(15,000)
Intersegment Time 1 µs
Averaging Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
Envelope (Extrema) Envelope, floor, or roof for up to 1 million sweeps
Interpolation Linear or Sin x/x (2 pt and 4 pt); automatically set when HD1024 is enabled
 

Vertical, Horizontal, Acquisition - Digital Channels

Maximum Input Frequency 250 MHz
Minimum Detectable Pulse Width 2 ns
Input Channels 16 Digital channels
Input Impedance (Flying Leads) 100 kΩ || 5 pF
Input Dynamic Range ± 20V
Maximum Input Voltage ±30V Peak
Maximum Input Voltage Swing 400mV
Threshold Groupings Pod 2: D15 - D8, Pod 1: D7 - D0
Threshold Selections TTL, ECL, CMOS (2.5 V, 3.3 V, 5 V), PECL, LVDS or User Defined
Threshold Accuracy ±(3% of threshold setting + 100mV)
User Defined Threshold Range ±10 V in 20 mV steps
User Defined Hysteresis Range 100 mV to 1.4 V in 100 mV steps
Sample Rate 1.25 GS/s
Record Length 128MS - 16 Channels
 

Triggering System

External Trigger Sensitivity, (Edge Trigger) 2 div @ 1 GHz
1.5 div @ < 500 MHz
1 div @ <200 MHz
0.9 div @<10 MHz
(DC, AC, and LFRej coupling)
Max Trigger Frequency (C1-C4, Aux In, SMART Trigger) 2.0 GHz @ ≥ 10 mV/div
(minimum triggerable width 200 ps)
Modes Normal, Auto, Single, and Stop
Sources Any input channel, Ext, Ext/10, or line; slope and level unique to each source (except line trigger)
Coupling DC, AC, HFRej, LFRej
Pre-trigger Delay 0-100% of memory size (adjustable in 1% increments of 100 ns)
Post-trigger Delay 0-10,000 Divisions in real time mode, limited at slower time/div settings or in roll mode
Hold-off From 2 ns up to 20 s or from 1 to 99,999,999 events
Internal Trigger Level Range ±4.1 div from center (typical)
External Trigger Level Range Ext (±0.4 V); Ext/10 (±4 V)
Maximum Trigger Rate 1,000,000 waveforms/second (in Sequence Mode, up to 4 channels)
Trigger Sensitivity with Edge Trigger ProBus Inputs 2 div @ < 4 GHz
1.5 div @< 2 GHz
1 div @ < 200 MHz
0.9 div @<10 MHz
(DC, AC, and LFRej coupling, ≥ 10 mV/div, 50 Ω)
 

Trigger Types

Exclusion Triggering Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
Multi-Stage: Qualified Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events.
Edge Triggers when signal meets slope (positive, negative, or either) and level condition.
Width Triggers on positive or negative glitches with selectable widths.
Minimum width 500 ps, maximum width: 20 s
Glitch Triggers on positive or negative glitches with selectable widths. Minimum width 200 ps, maximum width: 20 s
Window Triggers when signal exits a window defined by adjustable thresholds
Pattern Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don't care. The High and Low level can be selected independently. Triggers at start or end of the pattern.
TV-Composite Video Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative).
Runt Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew Rate Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
Interval Triggers on intervals selectable between 1 ns and 20 s.
Dropout Triggers if signal drops out for longer than selected time between 1 ns and 20 s.
Measurement Trigger Select from a large number of measurement parameters trigger on a measurement value with qualified limits. Can be used as only trigger or last event in a Cascade Trigger.
Multi-Stage: Qualified First In Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events.
Multi-Stage: Cascade (Sequence) Trigger, Capability Arm on "A" event, then Trigger on "B" event. Or Arm on "A" event, then Qualify on "B" event, and Trigger on "C" event.
Multi-Stage: Cascade (Sequence) Trigger, Types Cascade A then B: Edge, Window, Pattern (Logic) Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage B only.
Cascade A then B then C (Measurement): Edge, Window, Pattern (Logic), Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage C only.
Cascade A then B then C: Edge, Window, Pattern (Logic)
Multi-Stage: Cascade (Sequence) Trigger, Holdoff Holdoff between A and B or B and C is selectable by time (1ns to 20s) or number of events.
Measurement trigger selection as the last stage in a Cascade precludes a holdoff setting between the prior stage and the last stage.
 

Low Speed Serial Protocol Trigger (Optional)

Optionally available I2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN1.1, CAN2.0, CAN FD, LIN, FlexRay, MIL-STD-1553, AudioBus (I2S, LJ, RJ, TDM), USB1.x/2.0, SATA
 

High Speed Serial Protocol Trigger

Data Rates (Option HDO9K-80B-8B10B TD)
150 Mb/s - 3.125 Gb/s
Pattern Length 80 bits, NRZ or 8b10b
Clock Recovery Jitter 1 ps rms + 0.3% Unit Interval rms for PRBS data patterns with 50% transition density
Hardware Clock Recovery Loop BW PLL Loop BW = Fbaud/5500, 100 Mb/s to 2.488 Gb/s (typical)
 

Measurement Tools

Measurement Parameters - Horizontal Bit rate, Cycles, Delay, Delta Delay, Duty Cycle, Duration, Frequency, First, Last, Narrow band phase, Narrow band power, Number of points, Period, Width, Phase, Time @ minimum (min.), Time @ maximum (max.), Delta time @ level, Delta time @ level from trigger, X @ max., X @ min.

Cycle-Cycle Jitter, N-Cycle, N-Cycle with start selection, Frequency @ level, Period @ level, Half Period, Width @ level, Time Interval Error @ level, Setup, Hold, Skew, Duty Cycle @ level, Duty Cycle Error, Edge @ lv (counts edges)
Measurement Parameters Amplitude, Area, Base (Low), Bit rate, Cycles, Delay, Delta Delay, Duty Cycle, Duration, Fall time (90-10%, 80-20%, @ level), Frequency, First, Last, Level @ x, Maximum, Mean, Median, Minimum, Narrow band phase, Narrow band power, Number of points, + Overshoot, - Overshoot, Peak-to-peak, Period, Risetime (10-90%, 20-80%, @ level), RMS, Std. deviation, Top, Width, Phase, Time @ minimum (min.), Time @ maximum (max.), Delta time @ level, Delta time @ level from trigger, X @ max., X @ min.

Cycle-Cycle Jitter, N-Cycle, N-Cycle with start selection, Frequency @ level, Period @ level, Half Period, Width @ level, Time Interval Error @ level, Setup, Hold, Skew, Duty Cycle @ level, Duty Cycle Error, Edge @ lv (counts edges)
Measurement Functionality Display up to 12 measurement parameters together with statistics, including mean, minimum, maximum, standard deviation, and total number. Each occurrence of each parameter is measured and added to the statistics table. Histicons provide a fast, dynamic view of parameters and waveshape characteristics. Parameter math allows addition, subtraction, multiplication, or division of two different parameters. Parameter gates define the location for measurement on the source waveform.
Measurement Parameters - Vertical Amplitude, Base (Low), Level @ x, Maximum, Mean, Median, Minimum, Peak-to-peak, RMS, Std. deviation, Top
Measurement Parameters - Pulse Area, Fall time (90-10%, 80-20%, @ level), + Overshoot, - Overshoot, Risetime (10-90%, 20-80%, @ level),
 

Math Tools

Math Functionality Display up to 12 math functions traces (F1-F12). The easy-to-use graphical interface simplifies setup of up to two operations on each function trace, and function traces can be chained together to perform math-on-math.
Math Operators - Basic Math Average (summed), Average (continuous), Difference (-), Envelope, Floor, Product (x), Roof, Sum (+)
Math Operators - Filters Enhanced resolution (to 11 bits vertical), Interpolate (cubic, quadratic, sinx/x), (SINx)/x
Math Operators - Frequency Analysis FFT (power spectrum, magnitude, phase, power density, real, imaginary, magnitude squared, up to 128 Mpts and rectangular, VonHann, Hamming, FlatTop and Blackman Harris windows)
Math Operators - Functions Absolute value, Correlation (two waveforms), Derivative, Deskew (resample), Exp (base e), Exp (base 10), Integral,Invert (negate), Log (base e), Log (base 10), Reciprocal, Rescale (with units), Square, Square root, Zoom (identity)
Math Operators - Other Sparse
 

Measurement and Math Integration

Measurement and Math Integration Histograms to display statistical distributions of up to 2 billion measurement parameters. Trend (datalog) of up to 1 million measurement parameters. Track (display parameter vs. time, time-correlated to acquisitions) any parameter. Persistence histogram and persistence trace (mean, range, sigma)
 

Pass/Fail Testing

Test Types Parameter limit testing, mask testing.
Pass/Fail Actions include: Save, Stop, Alarm, Pulse, Hardcopy, LabNotebook
 

Display System

Size Color 15.4" widescreen capacitive touch screen
Resolution WXGA; 1280 x 800 pixels.
Number of traces Display a maximum of 16 traces. Simultaneously display channel, zoom, memory and math traces.
Grid Styles Auto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y, Tandem, Quatro, Twelve, Sixteen
Waveform Representation Sample dots joined, or sample dots only
 

Integrated Second Display

Type Supports touch screen integration of user-supplied second display with split-grid capability.
(Note: touch screen driver for second display may not be a Fujitsu driver)
Size Supports touch screen integration of user-supplied second display with split-grid capability.
(Note: touch screen driver for second display may not be a Fujitsu driver)
 

Persistence Display

Analog and Color-Graded Persistence Variable saturation levels; stores each trace's persistence data in memory
Persistence Types Select analog, color, or three-dimensional
Trace Selection Activate persistence on all or any combination of traces
Persistence Aging Select from 500 ms to infinity
Sweep Display Modes All accumulated, or all accumulated with last trace highlighted
 

Zoom Expansion Traces

Zoom Expansion Traces Display up to 12 Zoom and 12 Math/Zoom traces
 

Internal Waveform Memory

Internal Waveform Memory 12 active waveform memory traces (M1-M12) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.
 

Setup Storage

Setup Storage Store to the internal hard drive, over the network, or to a USB-connected peripheral device.
 

Automatic Setup

Auto Setup Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical Scale Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range
 

Calibration

Auto Calibration Ensures specified DC and timing accuracy is maintained for 1 year minimum.
 

Processor/CPU

Type Intel® i5-3610 Dual Core, 2.7 GHz (or better)
Processor Memory 16 GB standard
Operating System Microsoft Windows® 7 For Embedded Systems 64Bits
Real Time Clock Date and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks.
 

Connectivity

Ethernet Port Supports 10/100/1000BaseT Ethernet interface (RJ45 port)
USB Host Ports 4 side USB 3.1 Gen1 ports, 2 side USB 2.0 ports, and 1 front USB 2.0 port support Windows compatible devices
USB Device Port 1 port - USBTMC over USB 3.1 Gen1
GPIB Port (optional) Supports IEEE - 488.2 (External)
External Monitor Port DisplayPort 1.1 (Qty. 2) and DVI-D (Qty. 1) to support customer-supplied external monitor.
Includes support for extended desktop operation with WQXGA (2560 x 1600) pixel resolution and split-grid capability on external monitor.
Supports touch screen integration of external monitor (Note: external display can not use a Fujitsu touch-screen driver).
Remote Control Via Windows Automation, or via LeCroy Remote Command Set
Network Communication Standard VXI-11 or VICP, LXI Class C (v1.2) Compliant
Peripheral Bus Teldyne LeCroy LBUS standard
 

Auxiliary Input

Signal Types Select External Trigger or External Clock Input on the front panel
Coupling 50 Ω: DC; 1 MΩ: AC, DC, GND
Max. Input Voltage 50 Ω: 5 Vrms; 1 MΩ: 250 Vmax (DC + Peak AC ≤ 10 kHz)
 

Auxiliary Output

Signal Types Select from control signals or Off
Output Signal 500 Hz-1 MHz square wave or DC level; 50 mV-1 V into 1 MΩ
Control Signals Trigger enabled, trigger out, pass/fail status, fast edge, off
Connector Type BNC, located on front
 

Probes

Probes Qty. (4) ÷10 Passive Probes
Probe System ProBus. Automatically detects and supports a variety of compatible probes
Scale Factors Automatically or manually selected depending on probe used
Calibration Output Default is 1kHz square wave, 1Vp-p (typical), output to probe hook. Settable from 500 Hz to 1 MHz square wave; 50 mV to 1.0V.
 

Power Requirements

Voltage 100-240 VAC ±10% at 50/60 Hz ±5%; 110-120 VAC ±10% at 400 Hz ±5%; Automatic AC Voltage Selection
Nominal Power Consumption 415 W / 415 VA
Max. Power Consumption 500 W / 500 VA (with all PC peripherals and active probes connected to 4 channels)
 

Environmental

Temperature (Operating) +5 °C to +40 °C
Temperature (Non-Operating) -20 °C to +60 °C
Humidity (Operating) 5% to 90% relative humidity (non-condensing) up to +31 °C.
Upper limit derates to 50% relative humidity (non-condensing) at +40 °C.
Humidity (Non-Operating) 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating) Up to 3,000 m at or below +30 °C
Altitude (Non-Operating) Up to 40,000 ft. (12,192 m)
Random Vibration (Operating) 0.31 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Random Vibration (Non-Operating) 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Functional Shock 30 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
 

Size and Weight

Dimensions (HWD) 14.1" H x 17.5" W x 9.5" D (358 x 445 x 242 mm)
Weight 25.8 lbs. (11.7 kg)
Shipping Weight 42 lbs. (19.0 kg)
 

Certifications

CE Certification
UL and cUL Listing
CE Compliant, UL and cUL listed; conforms to UL 61010-1 (3rd Edition), UL 61010-2-030 (1st Edition)
CAN/CSA C22.2 No. 61010-1-12
 

Warranty and Service

Warranty and Service 3-year warranty; calibration recommended annually.
Optional service programs include extended warranty, upgrades, and calibration services.
 

Mixed Signal Solutions

HDA125-18-LBUS
12.5 GS/s High-speed Digital Analyzer with 18ch QuickLink leadset and LBUS connection
HDA125-09-LBUS
12.5 GS/s High-speed Digital Analyzer with 9ch QuickLink leadset and LBUS connection
MS-500
500 MHz, 18 Channels, 2 GS/s, 50 Mpts/ch Mixed Signal Oscilloscope Option
MS-500-36
250 MHz,36 Ch,1 GS/s,25 Mpts/ch (500MHz,18 Ch,2 GS/s,50 Mpts/ch Interleaved) Mixed Signal Option
MS-250
250 MHz, 18 Channels, 1 GS/s, 10 Mpts/ch Mixed Signal Oscilloscope Option

Computer Upgrade

HDO9K-256GB-RSSD
256 GB Removable Solid State Drive option for HDO9000
HDO9K-256GB-RSSD-02
Additional 256 GB Solid State Drive for use with RSSD option.

Remote Control/Network Options

USB2-GPIB
External USB 2.0 to GPIB IEEE 488.2 adapter

Power Analysis Software

HDO9K-PWR
Power Analysis Option for HDO9000
HDO9k-DIG-PWR-MGMT
Digital Power Management Analysis Software Option

Serial Trigger and Decode

HDO9K-1553 TD
MIL-STD-1553 Trigger and Decode Option for HDO9000
HDO9K-1553 TDME
MIL-STD-1553 Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO9000
HDO9K-80B-8b10b TD
8b10b Decode Option for HDO9000. Includes 80 bit 3 Gb serial trigger
HDO9K-ARINC429BUS DME SYMBOLIC
ARINC 429 Bus Symbolic Decode, Measure/Graph, and Eye Diagram Option for HDO9000
HDO9K-MDIObus D
MDIO Decode for HDO9000 Series
HDO9K-ARINC429BUS DSYMBOLIC
ARINC 429 Bus Symbolic Decode Option for HDO9000
HDO9K-Audiobus TD
AudioBus Trigger and Decode Option for HDO9000
HDO9K-Audiobus TDG
AudioBus Trigger, Decode, and Graph Option for HDO9000
HDO9k-SPMIbus D
SPMI Decode for HDO9000 Series
HDO9K-CAN FDBUS TD
CAN and CAN FD Trigger and Decode Option for HDO9000
HDO9K-CAN FDBUS TDME
CAN and CAN FD Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO9000
HDO9K-CAN FDBUS TDME SYMBOLIC
CAN and CAN FD Symbolic Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO9000
HDO9K-CANBUS TD
CAN Trigger & Decode Option for HDO9000
HDO9K-CANBUS TDME
CAN Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO9000
HDO9K-CANBUS TDME SYMBOLIC
CAN Symbolic Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO9000
HDO9K-DigRF3Gbus D
DigRF 3G Bus Decode Option for HDO9000
HDO9K-DigRFV4bus D
DigRF V4 Bus Decode Option for HDO9000
HDO9K-DPHYbus D
MIPI D-PHY CSI-2, DSI Bus Decode Option for HDO9000
HDO9K-DPHYbus DP
MIPI D-PHY CSI-2, DSI Bus Decode and Physical Layer test Option for HDO9000
HDO9K-EMB TD
Bundle: Includes I2C, SPI, UART-RS232 Trigger and Decode Options for HDO9000
HDO9K-EMB TDME
Bundle: Incl. I2C, SPI, UART-RS232 Trigger, Decode, Measure/Graph, and Eye Diagram Opt. for HDO9000
HDO9K-EMB TDME
Bundle: Incl. I2C, SPI, UART-RS232 Trigger, Decode, Measure/Graph, and Eye Diagram Opt. for HDO9000
HDO9K-ENETbus D
ENET Bus Decode Option for HDO9000
HDO9K-FCbus D
FibreChannel Decode annotation Option for HDO9000
HDO9K-FLEXRAYBUS TD
FlexRay Trigger and Decode Option for HDO9000
HDO9K-FLEXRAYBUS TDMP
FlexRay Trigger, Decode, Measure/Graph and Physical Layer Option for HDO9000
HDO9K-I2CBUS TD
I2C Trigger and Decode Option for HDO9000
HDO9K-I2CBUS TDME
I2C Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO9000
HDO9K-LINBUS TD
LIN Trigger and Decode Option for HDO9000
HDO9K-LINBUS TDME
LIN Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO9000
HDO9K-MANCHESTERbus D
Manchester Bus Decode Option for HDO9000
HDO9K-MPHYbus D
MIPI M-PHY Bus Decode Option for HDO9000
HDO9K-MPHYbus DP
MIPI M-PHY Bus Decode and Physical Layer test Option for HDO9000
HDO9K-NRZbus D
NRZ Bus Decode Option for HDO9000
HDO9K-PCIebus D
PCIe Gen 1 Decode Option for HDO9000
HDO9K-PROTOBUS MAG
Serial Debug Toolkit - Measure Analyze Graph for HDO9000
HDO9K-ProtoSync
Decode Annotation and Protocol Analyzer Synchronization Option for HDO9000
HDO9K-ProtoSync-BT
Decode Annotation and Protocol Analyzer+Bit Tracer Synchronization Option for HDO9000
HDO9K-SASbus D
SAS Decode annotation Option for HDO9000
HDO9K-SATAbus TD
SATA Trigger and Decode Option for HDO9000
HDO9K-SENTbus D
SENT Bus Decode Option for HDO9000
HDO9K-SPACEWIREbus D
SpaceWire Decode Option for HDO9000
HDO9K-SPIBUS TD
SPI Trigger and Decode Option for HDO9000
HDO9K-SPIBUS TDME
SPI Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO9000
HDO9K-UART-RS232BUS TD
UART-RS232 Trigger and Decode Option for HDO9000
HDO9K-UART-RS232BUS TDME
UART-RS232 Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO9000
HDO9K-UNIPRObus D
MIPI UniPro Protocol Decoder Software Option for HDO9000
HDO9K-UPG-MPHY-UNIPRObus D
MPHY to UniPro Decoder Software Upgrade MPHY REQUIRED
HDO9K-USB2BUS TD
USB 2.0 Trigger and Decode Option for HDO9000
HDO9K-USB2BUS TDME
USB 2.0 Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO9000
HDO9K-USB2-HSICbus D
USB 2.0 HSIC Decode Option for HDO9000

Jitter Analysis Software

HDO9K-JITKIT
Clock, clock-data Jitter Analysis and views of time, statistical, spectral, and jitter overlay

Digital Filtering Software

HDO9K-DFP2
Digital Filter Software Package for HDO9000

Serial Data Compliance

QPHY-BroadR-Reach
QualiPHY Enabled BroadR-Reach Compliance Software Option. Requires either SDA2 or JTA2
QPHY-MOST50
QualiPHY Enabled MOST50 ePHY Compliance Software Option. Requires options DFP2 and SDM or SDA2
QPHY-MOST150
QualiPHY MOST150 oPHY and cPHY Compliance Software Option. Requires options DFP2 and SDM or SDA2
QPHY-MIPI-DPHY
QualiPHY Enabled MIPI DPHY Compliance Software Option
GRL-USB-PD
GRL USB Power Delivery Compliance Test Software
HDO9K-DDR2-TOOLKIT
DDR2 and LPDDR2 Debug Toolkit for HDO9000
GRL-USB-PD-C1
GRL USB Type-C Test Controller
HDO9K-DDR3-TOOLKIT
DDR3, DDR3L, LPDDR3, DDR2, and LPDDR2 Debug Toolkit for HDO9000
QPHY-DDR2
QualiPHY Enabled DDR2 Compliance Software Option
QPHY-DDR3
QualiPHY Enabled DDR3, DDR3L and LPDDR3 Compliance Software Option
QPHY-ENET
QualiPHY Enabled Ethernet 10/100/1000BT Compliance Software Option
QPHY-LPDDR2
QualiPHY Enabled LPDDR2 Compliance Software Option
HDO9K-UPG-DDR3-TOOLKIT
DDR3, DDR3L, LPDDR3, DDR2, and LPDDR2 Debug Toolkit Upgrade for HDO9000
QPHY-USB
QualiPHY Enabled USB 2.0 Compliance Software Option

Serial Data Analysis

HDO9K-EyeDrII
Eye Doctor (Virtual Probe and Equalizer Emulation Bundle) for HDO9000
HDO9K-CBL-DE-EMBED
Cable De-Embedding Option for HDO9000
HDO9K-SDAII
SDAII Software Option for HDO9000
HDO9K-SDM
Serial Data Mask Software Package for HDO9000

Other Software Options

HDO9K-XDEV
Developer's Tool Kit Option for HDO9000
HDO9K-EMC
EMC Pulse Parameter Software Package for HDO9000
HDO9K-ET-PMT
Electrical Telecom Pulse Mask Test Package for HDO9000
HDO9K-Q-SCAPE
Q-Scape Multi-tab Display Option for HDO9000
HDO9K-SPECTRUM
Spectrum Analyzer and Advanced FFT Option for HDO9000

Miscellaneous

OC1024-A
Instrument Cart with additional shelf and drawer
OC1021-A
Instrument Cart
HDO9K-Carrycase
HDO9000 Carrying Case
HDO9K-Rack
HDO9000 Rackmount

Synchronize Oscilloscope Options

HDO9k-8CH-SYNCH
HW kit to allow for 8 channel synch capability to combine 2 HDO9000 High Definition Oscilloscopes

Data Storage Software

HDO9K-AORM
Advanced Optical Recording Measurement Package for HDO9000
HDO9K-DDA
Disk drive analyzer software package for HDO9000
HDO9K-DDM2
Disk Drive Measurements Software Package for HDO9000

Mixed Signal Accessories

PK400-0
Extra Large Gripper Probe Set . Includes 22 probes
PK400-1
Large Gripper Probe Set for 0.10 inch (2.54mm) pin pitch. Includes 10 probes with color coded leads
PK400-2
Medium Gripper Probe Set for 0.04 inch (1.0mm) pin pitch. Includes 10 probes with color coded leads
PK400-3
Small Gripper Probe Set for 0.008 inch (0.2 mm) pin pitch. Includes 10 probes with color coded leads
MSO-3M
18 Pin 3M Interface cable MSO-3M (Mates with 3M part number 2520-6002)
MSO-DLS-18
16" Digital Lead Set, D0-D17
MSO-DLS-36
16" Digital Lead Set, D18-D35
HDA-DLS-18QL
18 channel QuickLink leadset for HDA125
HDA-DLS-09QL
9 channel QuickLink leadset for HDA125

Serial Data Test Fixtures

TF-ENET-B
10/100/1000BaseT Ethernet Test Fixture
TF-USB-B
USB 2.0 Compliance Test Fixture

Differential Probes (4-6 GHz)

D600A-AT
WaveLink D600 6 GHz/4.8Vp-p Differential Amplifier Module with Adjustable Tips.
Dx10-SI
Replacement Solder tip lead set for D410/D610
Dx20-SI
Replacement Solder tip lead set for D420/D620
Dx10-PT-KIT
WaveLink Dx10-PT Adjustable Positioner Tip Kit. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins(Qty. 4)/Sockets (Qty 2).
Dx20-PT-KIT
WaveLink Dx20-PT Adjustable Positioner Tip Kit. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2).
WL-PBUS-CASE
WaveLink ProBus Platform/Cable Assembly Kit for D410, D420, and D400A-AT WaveLink Probes.
Dx10-HiTemp
WaveLink Temperature Extension cables for Dx10. Includes 1 set of matched 30" high temperature cables, 1 solder tip lead set
Dx20-HiTemp
WaveLink Temperature Extension cables for Dx20. Includes 1 set of matched 30" high temperature cables, 1 solder tip lead set
D400A-AT
WaveLink D400 4 GHz/4.8Vp-p Differential Amplifier Module with Adjustable Tips
D410-A
WaveLink D410-A 4 GHz/2.5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with So Small Tip Module with Solder-in, Quick Connect, and Square Pin Lead Sets, plus accessories.
D420-A
WaveLink D420-A 4 GHz/5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Sold Small Tip Module with Solder-in, Quick Connect, and Square Pin Lead Sets, plus accessories.
D610-A
WaveLink D610-A 6 GHz/2.5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with So Small Tip Module with Solder-in, Quick Connect, and Square Pin Lead Sets, plus accessories.
D620-A
WaveLink D620-A 6 GHz/5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Sold Small Tip Module with Solder-in, Quick Connect, and Square Pin Lead Sets, plus accessories.
D410-A-PS
4 GHz Complete Probe System with Dx10-SI Solder-In Tip (Qty. 1), Dx10-QC Quick Connect (Qty. 1), Dx10-SP Square Pin (Qty. 1), and Dx10-PT-KIT Positioner Tip Browser (Qty. 1)
D420-A-PS
4 GHz Complete Probe System with Dx20-SI Solder-In Tip (Qty. 1), Dx20-QC Quick Connect (Qty. 1), Dx20-SP Square Pin (Qty. 1), and Dx20-PT-KIT Positioner Tip Browser (Qty. 1)
D610-A-PS
6 GHz Complete Probe System with Dx10-SI Solder-In Tip (Qty. 1), Dx10-QC Quick Connect (Qty. 1), Dx10-SP Square Pin (Qty. 1), and Dx10-PT-KIT Positioner Tip Browser (Qty. 1)
D620-A-PS
6 GHz Complete Probe System with Dx20-SI Solder-In Tip (Qty. 1), Dx20-QC Quick Connect (Qty. 1), Dx20-SP Square Pin (Qty. 1), and Dx20-PT-KIT Positioner Tip Browser (Qty. 1)
Dx10-QL
QuickLink Adapter for use with Dx10-A amplifiers
Dx20-QL
QuickLink Adapter for use with Dx20-A amplifiers
Dx10-QL-3SI
QuickLink Solder-In starter pack for use with Dx10 amplifier
Dx20-QL-3SI
QuickLink Solder-In starter pack for use with Dx20 amplifier
D610-A-CCNIST
NIST Calibration for D610-A. Includes test data.
D620-A-CCNIST
NIST Calibration for D620-A. Includes test data.
D410-A-CCNIST
NIST Calibration for D410-A. Includes test data.
D420-A-CCNIST
NIST Calibration for D420-A. Includes test data.

Active Voltage Probes

ZS1500-QUADPAK
Set of 4 ZS1500, 1.5 GHz High Impedance Active Probes
ZS1000-QUADPAK
Set of 4 ZS1000, 1 GHz High Impedance Active Probes
ZS1500
1.5 GHz, 0.9 pF, 1 MOhm Active Voltage Probe
ZS1000
1 GHz, 0.9 pF, 1 MOhm Active Voltage Probe
ZS2500
2.5 GHz, 0.9 pF, 1 MOhm Active Voltage Probe
ZS2500-QUADPAK
Set of 4 ZS2500, 2.5 GHz High Impedance Active Probes
ZS4000
4.0 GHz, 0.6 pF, 1 MOhm Active Voltage Probe

Differential Probes (<= 1.5 GHz)

AP033
500 MHz Differential Probe
ZD200
200 MHz, 3.5 pF, 1 MOhm Active Differential Probe, ±20 V
ZD500
500 MHz, 1.0 pF Active Differential Probe, ±8 V
ZD1000
1 GHz, 1.0 pF Active Differential Probe, ±8 V
ZD1500
1.5 GHz, 1.0 pF Active Differential Probe, ±8 V

Current Probes

CP150
150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 2 meter cable
CP500
500 A, 2 MHz Current Probe - AC/DC, 500 A rms, 700 A Peak Pulse, 6 meter cable
CP030
30A, 50 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP031
30A, 100 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP030A
30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP031A
30A, 100 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CA10
Programmable Current Sensor to ProBus Adapter for use with third party current sensors
CA10-QUADPAK
Set of 4 CA10 Programmable Current Sensor to ProBus Adapters for third-party current sensors

High Voltage Passive Probes

PPE4KV
100:1 400 MHz 50 MOhms High-Voltage Probe
PPE5KV
100:1 400 MHz 50 MOhms High-Voltage Probe
PPE6KV
1000:1 400 MHz 50 MOhms High-Voltage Probe
HVP120
400 MHz, 1kV Vrms High-Voltage Passive Probe

Passive Probes

PP008-1
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP009-1
500 MHz passive probe, 10: 1 (for WaveSurfer Xs), mechanically identical to PP005A
PP022-1
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP024-1
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm

High Voltage Differential Probes

AP031
700 V, 25 MHz High-Voltage Differential Probe (÷10, ÷100)
HVD3102
1kV, 25 MHz High Voltage Differential Probe
HVD3106
1kV, 120 MHz High Voltage Differential Probe
HVD3605
6kV, 100 MHz High Voltage Differential Probe
HVD3102-NOACC
1kV, 25 MHz High Voltage Differential Probe without tip Accessories
HVD3106-NOACC
1kV, 120 MHz High Voltage Differential Probe without tip Accessories
HVD3206
2kV, 120 MHz High Voltage Differential Probe
HVD3206-6M
2kV, 80 MHz High Voltage Differential Probe with 6m cable

Optical to Electrical Converters

OE425
Optical-to-Electrical Converter, 500-870 nm ProBus BNC Connector
OE455
Optical-to-Electrical Converter, 950-1630 nm ProBus BNC Connector

Differential Amplifiers

DA1855A
1 Ch, 100 MHz Differential Amplifier with Precision Voltage Source
DXC100A
÷100 or ÷10 Selectable, 250 MHz Passive Differential Probe Pair
DXC200
÷1, 50 MHz, Passive Differential Probe Pair
DXC-5100
100:1 250 MHz 40 Mohm 2.75pf Differential Probe Pair;
DA101
10:1 1 MOhm Passive Attenuator
DA1855A-PR2
2 Ch, 100 MHz, Differential Amplifier with Precision Voltage Source
DA1855A-PR2-RM
2 Ch, DA1855A with Rackmount (must be ordered at time of purchase, no retrofit)
DA1855A-RM
DA1855A with rackmount;

Probe Parts and Kits

PACC-CL001
Probe Clips For SMD 0.5MM
PACC-LD004
Replacement Right Angle L-Lead
PACC-LD003
Replacement Right Angle S-Lead
PACC-CD008
Bendable Pogo Ground (qty of 2)
Dx10-HiTEMP
WaveLink Temperature Extension cables for Dx10. Includes 1 set of matched 30" high temperature cables, 1 solder tip lead set
Dx20-HiTEMP
WaveLink Temperature Extension cables for Dx20. Includes 1 set of matched 30" high temperature cables, 1 solder tip lead set
Dx10-SI-HiTEMP
Replacement Solder tip leadset for use with D410/D610 and temperature extension cables
Dx20-SI-HiTEMP
Replacement Solder tip leadset for use with D420/620 and temperature extension cables
PACC-ZD008
Y-Lead Adapter
PACC-ZD001
Y lead Adapter for ZD differential probes - Qty 1
PACC-ZD002
Solder-in lead for ZD differential probe - QTY 2
PACC-ZD003
Long spring ground for ZD differential probe - QTY 2
PACC-ZD004
Tip saver for ZD differential probe - QTY 2
PACC-ZD005
Swivel tip adapter for ZD differential probe - QTY 1
PACC-ZD006
Small IC adapter for ZD differential probe - QTY 2
PACC-ZD007
Replacement Accessory kit for ZD200
PK111
Replacement Accessory kit for ZD500, ZD1000, and ZD1500
Dx10-Cable-HiTemp
Replacement 30" matched cable set for use with Dx10 HiTemp Solder tip leadset
Dx20-Cable-HiTemp
Replacement 30" matched cable set for use with Dx20 HiTemp Solder tip leadset

Probe Adapters

CA10
Programmable Current Sensor to ProBus Adapter for use with third party current sensors
TPA10
TekProbe to ProBus Probe Adapter
TPA10-QUADPAK
Set of 4 TPA10 TekProbe to ProBus Probe Adapters. Includes soft carrying case.

Active Voltage Rail Probe

RP4030
Power/Voltage Rail Probe. 4 GHz bandwidth, 1.2x attenuation, +/-30V offset, +/-800mV Includes a complete set of solder-in leads, coaxial cables, and PCB mounts.
RP4000-MCX-LEAD-SI
Qty. 3 MCX 4 GHz solder-in lead accessories (additional to those supplied with RP4030), 18cm long
RP4000-MCX-PCBMOUNT
Qty. 10 MCX 6mm x 6mm PCB mounts (additional to those supplied with RP4030)
RP4000-MCX-CABLE-UFL
Qty. 3 3 GHz MCX to U.FL ultra-miniature coax cable, 8cm long (add'l to those supplied with RP4030)
RP4000-UFL-PCBMOUNT
Qty. 10 U.FL 3mm x 3mm PCB mounts (additional to those supplied with RP4030)
RP4000-BROWSER
RP4030 350 MHz Browser Tip accessory. Includes 0 Ohm (1x), 450 Ohm (10x) and 950 Ohm (20x) tips.

High Voltage Fiber Optically-isolated Probes

HVFO103
High Voltage Fiber Optic Probe, 60 MHz Bandwidth. Includes soft-carrying case. Requires attenuating tip (ordered separately). Includes Qty. 1 1m Fiber Optic Cable.
HVFO100-1X-TIP
HVFO103 +/-1V (1x Attenuation) Tip Accessory
HVFO100-5X-TIP
HVFO103 +/-5V (5x Attenuation) Tip Accessory
HVFO100-20X-TIP
HVFO103 +/-20V (20x Attenuation) Tip Accessory
HVFO100-40X-TIP
HVFO103 +/-40V (40x Attenuation) Tip Accessory
HVFO103-XMITTER
HVFO103 Spare Amplifier/Modulating Transmitter
HVFO-1M-FIBER
HVFO 1m Fiber Optic Cable Accessory
HVFO-2M-FIBER
HVFO 2m Fiber Optic Cable Accessory
HVFO-6M-FIBER
HVFO 6m Fiber Optic Cable Accessory