WaveMaster 804Zi-A
4 GHz, 40 GS/s, 4ch, 20 Mpts/Ch DSO with 15.3" WXGA Color Display. 50 ohm and 1 Mohm Input
WaveMaster 825Zi-A (25 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate) WaveMaster 830Zi-A (30 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate) WaveMaster 845Zi-A (45 GHz Bandwidth, 1 Input Channel, 120 GS/s Max Sample Rate; 30 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate) Limited Availability
Check up to three models.
45 GHz Real-Time Bandwidth Teledyne LeCroy has again broken bandwidth barriers by utilizing widely adopted and proven SiGe processes, custom 2nd generation ASIC designs, and 6th generation Digital Bandwidth Interleave (DBI) technology to achieve unprecedented real-time oscilloscope performance: - 45 GHz
- 120 GS/s
- 768 Mpts/Ch Analysis Memory
20 GHz/4ch Model Four channel performance at 20 GHz is pristine with exceptional rise time, overshoot, total and random jitter noise floor, and electrical noise performance. Teledyne LeCroy — The Analysis Memory Leader Teledyne LeCroy has found a way to make long acquisition memory seamless and pain free to use. The WaveMaster 8 Zi-A Series' proprietary X-Stream II architecture supports capturing, zooming, measuring and analyzing multiple waveforms at up to 768 Mpts deep. WaveMaster 8 Zi-A's proprietary architecture design is augmented with an Intel® Core™ 2 Quad processor (12 GHz effective clock rate), high-speed serial data buses, Windows 7 64-bit OS and 8 GB of RAM. What you experience is processing speed 10-100x faster compared to other oscilloscopes in this class. Highest Stability Timebase and Lowest Jitter Noise Floor An exceptionally accurate and stable time base is incorporated for the best possible jitter measurement accuracy jitter noise floor is as low as 125 fsrms. Teledyne LeCroy provides highly stable measurements at full (768 Mpts) record lengths, simplifying debug of low frequency events. Freedom from Probing Limitations High bandwidth differential probes (up to 25 GHz), single-ended active probes, current probes, high-voltage, and mixed signals all connect to the WaveMaster 8 Zi-A oscilloscope and give you a total system view. All WaveMaster 8 Zi-A oscilloscopes contain selectable 50 Ohm and 1 MOhm input capability and can be used with any Teledyne LeCroy probe - passive or active - without requiring external adapters or power supplies.
Vertical System | | Analog Bandwidth @ 50 Ω (-3 dB) (2.4/2.92 Inputs) | Not Applicable | | Analog Bandwidth (Max) | 4 GHz | | Analog Bandwidth @ 50 Ω (-3 dB) (1.85mm Inputs) | Not Applicable | | Analog Bandwidth @ 50 Ω (-3 dB) (ProLink Input) | 4 GHz (≥10 mV/div) | | Analog Bandwidth @ 50 Ω (-3 dB) (ProBus Input) | 3.5 GHz (≥10 mV/div) | | Analog Bandwidth @ 1 MΩ (-3 dB) (ProBus Input) | 500 MHz (typical, ≥2 mV/div) | | Bandwidth | 4 GHz | | Rise Time (10–90%) | 95 ps (test limit, flatness mode) | | Rise Time (20–80%) | 71 ps (flatness mode) | | Input Channels | 4 (Any combination of ProLink and ProBus inputs) | | Bandwidth Limiters | 20 MHz, 200 MHz, 1 GHz | | Input Impedance | ProLink Inputs: 50 Ω+/-2% for ≤100 mV/div, 50 Ω+/-3% for >100 mV/div ProBus Inputs: 50 Ω+/-2% or 1 MΩ||16pF, 10 MΩ || 11 pF with supplied Probe | | Input Coupling | ProLink Inputs - 50 Ω: DC, GND ProBus Inputs - 1 MΩ: AC, DC, GND; 50 Ω: DC, GND | | Maximum Input Voltage | 50 Ω (ProLink): ±2 Vmax@≤100mV/div, 5.5Vrms@>100mV/div 50 Ω (ProBus): ±5 Vmax, 3.5 Vrms 1 MΩ (ProBus): 250 V max. (peak AC: < 10 kHz + DC) | | Channel-Channel Isolation | DC to 10 GHz: 50 dB (>315:1) 10 to 15 GHz: 46 dB (>200:1) 15 to 20 GHz: 40 dB (>100:1) (For any two ProLink input channels, same or different v/div settings, typical) | | Vertical Resolution | 8 bits; up to 11 bits with enhanced resolution (ERES) | | Sensitivity | 50 Ω (ProLink): 2 mV-1 V/div, fully variable (2-9.9 mV/div via zoom) 50 Ω (ProBus): 2 mV-1 V/div, fully variable; 1 MΩ (ProBus): 2 mV-10 V/div, fully variable | | DC Vertical Gain Accuracy (Gain Component of DC Accuracy) | ±1% F.S. (typical), offset at 0V; ±1.5% F.S. (test limit), offset at 0V | | Offset Range | 50 Ω (ProLink): ±500 mV @ 2-100 mV/div ±4 V @ >100 mV/div -1 V/div 50 Ω (ProBus): ±750 mV @ 2-100 mV/div ±4 V @ >100 mV/div -1 V/div 1 MΩ: ±1V @ 2-140 mV/div ±10V @ 142mV-1.40V/div ±100V @ 1.42V-10V/div | | DC Vertical Offset Accuracy | ±(1.5% of offset setting + 1.5% F.S. + 1 mV) (test limit) | | | Horizontal System | | Timebases | Internal timebase common to 4 input channels | | Time/Division Range | 20 ps/div-128 s/div (Real-Time Mode: 20 ps/div - 64 s/div; RIS mode: 20 ps/div - 10 ns/div, user selectable at ≤10ns/div; Roll mode: 100 ms/div up to 128 s/div, user selectable at ≥100 ms/div and ≤5 MS/s), depending on memory length
| | Clock Accuracy | < 1 ppm + (aging of 0.5ppm/yr from last calibration) | | Time Interval Accuracy | < 0.06 / SR + (clock accuracy* Reading) (rms) | | Jitter Noise Floor | For Acq. Length ≤10µs: 550 fsrms (TIE, typical) For Acq. Length >10µs: 600 fsrms (TIE, typical) | | Trigger and Interpolator Jitter | <0.1 ps rms (typical, software assisted), 2 ps rms (typical, hardware), | | Channel-Channel Deskew Range | ±9 x time/div. setting or 25 ns max. (whichever is larger), each channel | | External Timebase Reference (Input) | 10 MHz; 50 Ω impedance, applied at the rear input | | External Timebase Reference (Output) | 10 MHz; 50 Ω impedance, output at the rear | | External Clock | Not Available | | | Acquisition System | | Sample Rate | 40 GS/s (80 GS/s on 2 Ch with optional interleaving) | | Single-Shot Sample Rate/Ch | 40 GS/s on 4 Ch (80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device) | | Random Interleaved Sampling (RIS) | 200 GS/s for repetitive signals (20 ps/div to 10 ns/div) | | Maximum Trigger Rate | 1,000,000 waveforms/second (in Sequence Mode, up to 4 channels) | | Intersegment Time | 1 µs | | Memory Options (4 Ch / 2 Ch / 1Ch) | S-32 Option: 32M / 32M / 32M (7,500) M-64 Option: 64M / 64M / 64M (15,000) L-128 Option: 128M / 128M / 128M (15,000) VL-256 Option: 256M / 256M / 256M (15,000) Note: On all memory options, WM8Zi-2X80GS External Interleaving Device permits 80 GS/s on 1 or 2ch with twice the memory) | | Standard Memory (4 Ch / 2 Ch / 1Ch) (Number of Segments) | 20 M / 20 M / 20M (Memory and Sample Rate can be doubled in 1 or 2 Ch mode with use of WM8Zi-2X80GS External Interleaving Device) (2000) | | | Acquisition Processing | | Averaging | Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps | | Enhanced Resolution (ERES) | From 8.5 to 11 bits vertical resolution | | Envelope (Extrema) | Envelope, floor, or roof for up to 1 million sweeps | | Interpolation | Linear or Sin x/x | | | Triggering System | | Modes | Normal, Auto, Single, and Stop | | Sources | Any input channel, Aux, Aux/10, Line, or Fast Edge. Slope and level unique to each source (except line trigger) | | Coupling Mode | DC, AC, HFRej, LFRej | | Pre-trigger Delay | 0-100% of memory size (adjustable in 1% increments of 100 ns) | | Post-trigger Delay | 0-10,000 divisions in real time mode, limited at slower time/div settings or in roll mode | | Hold-off by Time or Events | From 2 ns up to 20 s or from 1 to 99,999,999 events | | Internal Trigger Range | ±4.1 div from center | | Trigger Sensitivity with Edge Trigger (Ch 1-4) 1.85/2.4/2.92mm Inputs | Not Available | | Trigger Sensitivity with Edge Trigger (Ch 1–4) ProBus Inputs | 2 div @ < 3.5 GHz, 1.5 div @ < 1.75 GHz, 1.0 div @ < 200 MHz, (for DC coupling, ≥ 10 mV/div, 50 Ω ) | | Trigger Sensitivity with Edge Trigger (Ch 1–4) ProLink Inputs | 2 div @ < 4 GHz, 1.5 div @ < 3 GHz, 1.0 div @ < 200 MHz, (for DC, AC, LFRej coupling, ≥ 10 mV/div, 50 Ω ) | | External Trigger Sensitivity, (Edge Trigger) | 2 div @ < 1 GHz, 1.5 div @ < 500 MHz, 1.0 div @ < 200 MHz, (for DC coupling) | | External Trigger Input Range | Aux (±0.4 V); Aux/10 (±4 V) | | Max. Trigger Frequency, SMART Trigger | 2.0 GHz @ ≥ 10 mV/div (minimum triggerable width 200 ps) | | | Basic Triggers | | Edge | Triggers when signal meets slope (positive, negative, or either) and level condition. | | Window | Triggers when signal exits a window defined by adjustable thresholds | | TV-Composite Video | Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative). | | | SMART Triggers | | State or Edge Qualified | Triggers on any input source only if a defined state or edge occurred on another input source. Holdoff between sources is selectable by time or events. | | Qualified First | In Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events. | | Dropout | Triggers if signal drops out for longer than selected time between 1 ns and 20 s. | | Pattern | Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don't care. The High and Low level can be selected independently. Triggers at start or end of the pattern. | | | SMART Triggers with Exclusion Technology | | Glitch | Triggers on positive or negative glitches with widths selectable as low as 200ps to 20 s, or on intermittent faults. | | Width (Signal or Pattern) | Triggers on positive, negative, or both widths with widths selectable as low as 200ps to 20 s, or on intermittent faults. | | Interval (Signal or Pattern) | Triggers on intervals selectable between 1 ns and 20 s. | | Timeout (State/Edge Qualified) | Triggers on any source if a given state (or transition edge) has occurred on another source. Delay between sources is 1 ns to 20 s, or 1 to 99,999,999 events. | | Runt | Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns. | | Slew Rate | Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns. | | Exclusion Triggering | Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met | | | Cascade (Sequence) Triggering | | Capability | Arm on "A" event, then Trigger on "B" event. Or Arm on "A" event, then Qualify on "B" event, and Trigger on "C" event. Or Arm on "A" event, then Qualify on "B" then "C" event, and Trigger on "D" event | | Types | A, B, C, or D event: Edge, Glitch, Width, Window, Dropout, Interval, Runt, Slew Rate, or Pattern (analog) | | Holdoff | Holdoff between A and B, B and C, C or D, or any is selectable by time or number of events | | Reset | Reset between A and B, B and C, C and D, or any combination is selectable in time or number of events | | | Measurement Trigger | | Measurement Trigger | Select from a large number of measurement parameters trigger on a measurement value with qualified limits. Can be used as only trigger or last event in a Cascade Trigger. | | | High Speed Serial Protocol Triggering | | Data Rates | Option WM8Zi-HSPT: 100 Mb/s - 2.7 Gb/s, 3.0, 3.125 Gb/s, Channel 4 input only Option WM8Zi-14GBIT-80B-8B10B-TD: 600 Mb/s to 14.1 Gb/s, Channel 4 input only | | Pattern Length | 80 bits NRZ, eight 8b/10b symbols | | Clock and Data Outputs | Option: WM8Zi-HSPT: 400mVpp (typical) AC coupled Option WM8Zi-14GBIT-80B-8B10B-TD: No Clock and Data Recovery outputs provided | | Clock Recovery Jitter | Option WM8Zi-HSPT: 2 ps rms + 0.3% Unit Interval rms for PRBS data patterns with 50% transition density | | Hardware Clock Recovery Loop BW | Option WM8Zi-HSPT: PLL Loop BW = Fbaud/5500, 100 Mb/s to 2.488 Gb/s (typical) | | | Low Speed Serial Protocol Triggering (Optional) | | Optionally available | I2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN, LIN, FlexRay, I2S (Audio), MIL-1553 | | | Color Waveform Display | | Type | Color 15.3" flat panel TFT-Active Matrix LCD with high resolution touch screen | | Resolution | WXGA; 1280 x 768 pixels. | | Number of traces | Display a maximum of 8 traces. Simultaneously display channel, zoom, memory and math traces. | | Grid Styles | Auto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y | | Waveform Representation | Sample dots joined, or sample dots only | | | LeCroy WaveStream™ Fast Viewing Mode | | Intensity | 256 Intensity Levels, 1-100% adjustable via front panel control | | Types | Select analog or color-graded | | Number of Channels | up to 4 simultaneously | | Max Sampling Rate | 40 GS/s (80 GS/s when operated in ≥ 20 GHz Mode) | | Persistence Aging | Select from 500 ms to Infinity | | Waveforms/second (continuous) | up to 2500 Waveforms/second | | Operation | Front panel toggle between WaveStream ON (Analog), ON (Color) and OFF | | | Automatic Setup | | Auto Setup | Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals | | Find Vertical Scale | Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range | | | Probes | | Probes
| Qty. (4) ÷10 Passive Probes | | Probe System: ProBus | Probus and ProLink. Automatically detects and supports a variety of compatible probes | | Scale Factors | Automatically or manually selected depending on probe used | | Calibration Output | 1kHz square wave, 1Vpp (typical), output to probe hook | | | Integrated Second Display | | Type | Color 15.3" flat panel TFT-Active Matrix LCD with high resolution touch screen | | Resolution | WXGA; 1280 x 768 pixels | | | Analog Persistence Display | | Analog and Color-Graded Persistence | Variable saturation levels; stores each trace's persistence data in memory | | Trace Selection | Activate persistence on all or any combination of traces | | Sweep Display Modes | All accumulated, or all accumulated with last trace highlighted | | Persistence Types | Select analog, color, or three-dimensional | | Persistence Aging | Select from 500 ms to infinity | | | High Speed Digitizer Output (Option) | | Type | LeCroy LSIB | | Transfer Rate | up to 325 MB/s (typical) | | Output Protocol | PCI Express, Gen 1 (4 lanes utilized for data transfer) | | Control Protocol | TCP/IP | | Command Set | Via Windows Automation, or via LeCroy Remote Command Set | | | Processor/CPU | | Type | Intel ® CoreTM i7-2600 Quad, 2.6 GHz (up to 3.8 GHz in Turbo mode) (or better) | | Processor Memory | 8 GB standard, up to 32 GB optional | | Operating System | Microsoft Windows ® 7 Professional Edition (64-bit) | | Real Time Clock | Date and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks. | | | Setup Storage | | Front Panel and Instrument Status | Store to the internal solid-state drive, over the network, or to a USB-connected peripheral device. | | | Interface | | Remote Control | Via Windows Automation, or via LeCroy Remote Command Set | | Network Communication Standard | VXI-11 or VICP, LXI Class C (v1.2) Compliant | | GPIB Port (optional) | Supports IEEE - 488.2 | | LSIB Port (optional) | Supports PCIe Gen1 x4 protocol with LeCroy supplied API | | Ethernet Port | Supports 10/100/1000BaseT Ethernet interface (RJ45 port) | | USB Ports | minimum 6 total (incl. 3 front panel) USB 2.0 ports support Windows compatible devices | | External Monitor Port | 15 pin D-Type WXGA compatible to support customer-supplied external monitor. DVI connector to support LeCroy WPZi-EXTDISP-15 additional touch screen display accessory. Includes support for extended desktop operation with optional LeCroy or other second monitor. | | Serial Port | Not Available | | Peripheral Bus | LeCroy LBUS standard | | | Auxiliary Input | | Signal Types | For External Trigger Input | | Coupling | 50 Ω: DC; 1 MΩ: AC, DC, GND | | Max. Input Voltage | 50 Ω: 5 Vrms; 1 MΩ: 250 V (Peak AC < 10 kHz + DC) | | | Auxiliary Output | | Connector Type | BNC, located on front | | Signal Types | Select from calibrator, control signals or Off | | Output Signal | 500 Hz-5 MHz square wave or DC level; 0.0 to 500 mV into 50 Ω (0-1 V into 1 MΩ) | | Control Signals | Trigger enabled, trigger out, pass/fail status, off | | | General | | Auto Calibration | Ensures specified DC and timing accuracy is maintained for 1 year minimum. | | | Power Requirements | | Voltage | 100-240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection, Installation Category II | | Max. Power Consumption | 975 W / 975 VA | | | Electrical Characteristics | | DC Input Resistance (nominal) | Display up to 12 Zoom and 12 Math/Zoom traces | | | Environmental and Safety | | Temperature (Operating) | +5 °C to +40 °C including CD-RW/DVD-ROM drive | | Temperature (Non-Operating) | -20 °C to +60 °C | | Humidity (Operating) | 5% to 80% relative humidity (non-condensing) up to +31 °C. Upper limit derates to 50% relative humidity (non-condensing) at +40 °C. | | Humidity (Non-Operating) | 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F | | Altitude (Operating) | Up to 10,000 ft. (3048 m) at or below +25 °C | | Altitude (Non-Operating) | Up to 40,000 ft. (12,192 m) | | Random Vibration (Operating) | 0.5 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes | | Random Vibration (Non-Operating) | 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes | | Functional Shock | 20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total | | | Physical Dimensions | | Dimensions (HWD) | 14"H x 18.4"W x 16"D (355 x 467 x 406 mm) | | Weight | 51.5 lbs. (23.4 kg) | | Shipping Weight | 70.0 lbs. (31.8 kg) | | |
Memory Options | WM8Zi-S-32 32 Mpt/Ch Memory Option | WM8Zi-M-64 64 Mpt/Ch Memory Option | WM8Zi-L-128 128 Mpt/Ch Memory Option | WM8Zi-VL-256 256 Mpt/Ch Memory Option | Sampling Rate Options | WM8Zi-2X80GS 80 GS/s on 2ch Sampling Rate Option for WaveMaster/SDA/DDA 8 Zi and 8Zi-A(not available for 820Zi, 825Zi/Zi-A, 830Zi/Zi-A, 9x30Zi-A, 845Zi-A or 9x45Zi-A).Includes two separate external interleaving devices with storage case. | High Speed Output Accessories | LSIB-HOSTBOARD PCI Express x4 Host Interface Board for desktop PC | LSIB-HOSTCARD PCI Express x1 Express Card Host Interface for laptop Express Card slot | LSIB-CABLE-3M PCI Express x 4 3-meter cable with x4 cable connectors included | LSIB-CABLE-7M PCI Express x 4 7-meter cable with x4 cable connectors include | Serial Data Analysis | WM8Zi-SDAIII-CompleteLinQ Bundle - Multi-Lane SDA LinQ Framewk, incl. Eye, Jitter, Noise, Xtalk Meas, w/EyeDrII & VirtualProbe | WM8Zi-SDAIII-CrossLinQ Multi-Lane Serial Data Analysis LinQ Framework, Eye, Jitter, Noise and Crosstalk Measurements | WM8Zi-SDAIII-Crosstalk Single-Lane Serial Data Analysis Framework, Eye, Jitter, Noise and Crosstalk Measurements | WM8Zi-SDAIII-LinQ Multi-Lane Serial Data Analysis LinQ Framework, Eye and Jitter Measurements | WM8Zi-SDAIII Single-Lane Serial Data Analysis Framework, Eye and Jitter Measurements | WM8Zi-EYEDRII-VP Bundle - EyeDrII and VirtualProbe Toolkits | WM8Zi-EYEDRII Signal Integrity Toolkit - Channel & Fixture De-embedding/Emulation, Tx/Rx Equalization | WM8Zi-VIRTUALPROBE Advanced De-embedding, Emulation and Virtual Probing Toolkit | WM8Zi-CBL-DE-EMBED Cable De-Embedding Option for WaveMaster 8 Zi Series Oscilloscopes,Serial Data Analyzers, and Disk Driver Analyzers | Serial Data Compliance | QPHY-MOST50e QualiPHY Enabled MOST50 ePHY Compliance Software Option. Requires options DFP2 and SDM or SDA2 | QPHY-MOST150o QualiPHY Enabled MOST150 oPHY Compliance Software Option. Requires options DFP2 and SDM or SDA2 | QPHY-BroadR-Reach QualiPHY Enabled BroadR-Reach Compliance Software Option. Requires either SDA2 or JTA2 | QPHY-MIPI-DPHY QualiPHY Enabled MIPI DPHY Compliance Software Option | QPHY-PCIe3 QualiPHY Enabled PCIe 3.0 Compliance Software Option | QPHY-DDR2 QualiPHY Enabled DDR2 Compliance Software Option | QPHY-DDR3 QualiPHY Enabled DDR3 Compliance Software Option | QPHY-ENET QualiPHY Enabled Ethernet 10/100/1000BT Compliance Software Option | QPHY-HDMI QualiPHY Enabled HDMI Compliance Test Software | QPHY-LPDDR2 QualiPHY Enabled LPDDR2 Compliance Software Option | QPHY-SATA-TSG-RSG QualiPHY Enabled SATA (PHY, TSG, RSG, and OOB) Compliance Software Option | QPHY-USB QualiPHY Enabled USB 2.0 Compliance Software Option | ENET-2ADA-BNCSMA Adapter Set- 2 BNC/M to SMA/F | ENET-2CAB-SMA018 Cable Set- 2 SMA-SMA 18 inches | ENET-2CAB-SMA036 Cable Set- 2 SMA-SMA 36 inches | WM8Zi-ET-PMT Electrical Telecom Pulse Mask Test Package for WaveMaster 8 Zi Series | WM8Zi-SDM Serial Data Mask Software Package for WaveMaster 8 Zi Series | QPHY-SFI QualiPHY Enabled SFI Compliance Software Option | Computer Upgrade | WM8Zi-500GB-HD Upgrade from standard size hard drive to 500 GB hard drive | WM8Zi-500GB-RHD-02 Additional 500 GB Hard Drive for WM8Zi or 8Zi-A. Includes Windows 7 OS,LeCroy oscilloscope software and critical scope operational file duplicates. | WM8Zi-128GB-RSSD-02 Addl 128 GB SSD for WM8Zi. Includes Windows 7 OS,LeCroy oscilloscope software and critical scope operational file duplicates. | WM8Zi-8-UPG-32GBRAM 8 GB to 32 GB CPU RAM Upgrade Option | Serial Trigger and Decode | WM8Zi-USB2-HSICbus D USB 2.0 HSIC Decode Option | WM8Zi-64b66b D 64b66b Decode Option | WM8Zi-VBA Vehicle Bus Analyzer BundleIncludes CAN TDM, CAN Symbolic, FlexRay TDP, LIN TD and Protobus MAG. | WM8Zi-FCbus D FibreChannel decode annotation option for WaveMaster 8Zi series | WM8Zi-SASbus D SAS Decode annotation option for WaveMaster 8Zi series | WM8Zi-DigRFV4bus D DigRF V4 Bus Decode option for WaveMaster 8Zi series | WM8Zi-Manchesterbus D Manchester Bus Decode Option for WaveMaster 8Zi | WM8Zi-ENETbus D ENET Bus Decode Option for WaveMaster 8Zi | WM8Zi-SATAbus D SATA Decode option for WaveMaster 8ZiSupports SATA Gen 1, 2, and 3. | WM8Zi-1553 TD MIL-STD-1553 Trigger and decode option for WaveMaster/SDA/DDA 8Ziand 8Zi-A Oscilloscopes and Analyzers | WM8Zi-8B10B D 8b10b Decode Option for WaveMaster/SDA/DDA 8Zi and 8Zi-A Oscilloscopes and Analyzers | WM8Zi-ARINC429bus DSymbolic ARINC 429 Bus Symbolic Decode option for WaveMaster 8Zi | WM8Zi-AudioBus TD AudioBus trigger and decode for WaveMaster/SDA/DDA 8Zi and 8Zi-A Oscilloscopes and Analyzers | WM8Zi-AudioBus TDG AudioBus trigger, decode, and graph for WaveMaster/SDA/DDA 8Zi and 8Zi-A Oscilloscopes and Analyzers | WM8Zi-CANbus TD CAN Bus Trigger & Decode Option for WaveMaster/SDA/DDA 8Zi and 8Zi-A Oscilloscopes and Analyzers | WM8Zi-CANbus TDM CAN Bus Trigger, Decode, and Measure Option for WaveMaster/SDA/DDA 8Zi and 8Zi-A Oscilloscopes andAnalyzers | WM8Zi-EMB Embedded bundle, Includes I2C TD, SPI TD, UART TD | WM8Zi-DigRF3Gbus D DigRF 3G Bus Decode option for WaveMaster 8Zi | WM8Zi-DPHYbus D D-PHY Bus Decode option for WaveMaster 8Zi | WM8Zi-FlexRayBus TD FlexRay Bus Trigger & Decode Option for WaveMaster/SDA/DDA 8Zi and 8Zi-A Oscilloscopesand Analyzers | WM8Zi-MSO-EMB Embedded bundle, Includes MS-500-36 with I2C TD, SPI TD, UART TD | WM8Zi-FlexRayBus TDP FlexRay Bus Trigger, Decode, and Physical Layer Test Option for WaveMaster/SDA/DDA 8Zi and 8Zi-AOscilloscopes and Analyzers | WM8Zi-HSPT 100 Mb/s to 3.125 Gb/s High Speed Serial Trigger Option for WaveMaster 8 Zi and 8 Zi-AOscilloscopes & Disk Drive Analyzers | WM8Zi-I2Cbus TD I2C Bus Trigger & Decode Option for WaveMaster/SDA/DDA 8Zi and 8Zi-AOscilloscopes and Analyzers | WM8Zi-LINbus TD LIN Bus Trigger & Decode Option for WaveMaster/SDA/DDA 8Zi and 8Zi-AOscilloscopes and Analyzers | WM8Zi-PCIEbus D PCI Express (Gen 1.x, 2.0, and 3.0) Protocol Link Layer Decode Annotation for WaveMaster/SDA/DDA 8Ziand 8Zi-A Oscilloscopes and Analyzers | WM8Zi-PROTObus MAG Serial Debug Toolkit - Measure Analyze Graph for Wavemaster 8ZiCompatible with I2C, SPI, UART, CAN, LIN, FLX, D-PHY, DigRF 3G, DigRF v4, ARINC 429, MIL-STD-1553 | WM8Zi-ProtoSync Decode Annotation and Protocol Analyzer Software Synchronization Option for WaveMaster 8Zi/Zi-A | WM8Zi-ProtoSync-BT Decode Annotation and Protocol Analyzer+Bit Tracer SW Synchronization Option for WaveMaster 8Zi/Zi-A | WM8Zi-SPIbus TD SPI Bus Trigger & Decode Option for WaveMaster/SDA/DDA 8Zi and 8Zi-AOscilloscopes and Analyzers | WM8Zi-UART-RS232bus TD UART and RS232 Bus Trigger & Decode Option for WaveMaster/SDA/DDA 8Zi and 8Zi-AOscilloscopes and Analyzers | WM8Zi-USB2bus D USB 2.0 Bus Decode option for WaveMaster 8Zi | WM8Zi-USB3bus D USB 3.0 Decode option for WaveMaster 8ZiSupports USB 3.0, 2.0, 1.x | WM8Zi-DPHYbus DP MIPI D-PHY CSI-2, DSI Bus Decode and Physical Layer test option for WaveMaster 8Zi series | WM8Zi-MPHYbus D MIPI M-PHY Bus Decode option for WaveMaster 8Zi series | WM8Zi-MPHYbus DP MIPI M-PHY Bus Decode and Physical Layer test option for WaveMaster 8Zi series | WM8Zi-14GBIT-80B-8B10B-TD 80-bit NRZ and 8b/10b Serial Trigger (up to 14.1 Gb/s). Also includes 8b/10b Decode. | WM8ZI-SENTbus D SENT Bus Decode Option for WaveMaster 8Zi | Jitter Analysis Software | WM8Zi-JITKIT Clock, clock-data Jitter Analysis and views of time, statistical, spectral, and jitter overlay | Synchronize Oscilloscope Options | Zi-8CH-SYNCH HW Kit to allow combination of channels from two Zi or Zi-A oscilloscopes. Allows combination of allchannels from two oscilloscopes (8 channels total) or combination of all 20-30 GHz channels from two20-30 GHz 8Zi or 8Zi-A oscilloscopes (4 channels total), or combination of 45 GHz channels | Miscellaneous | KYBD-1 Keyboard, USB | WM8Zi-HARDCASE Hard carrying case for all WaveMaster, SDA, and DDA 8 Zi Series oscilloscopes | WM8Zi-SOFTCASE Soft carrying case for all WaveMaster, SDA, and DDA 8 Zi Series, and LM 9 Zi series oscilloscopes.Holds any WM/SDA/DDA 8 Zi, LM 9xxMZi, or 9CZi "Master" Model. | WM8Zi-RACKMOUNT Rack-mount accessory for converting a WaveMaster, SDA, and DDA 8 Zi series oscilloscopeto an 8U rack-mounted package | TTL-AUX-OUT TTL Auxiliary output adapter for 7Zi and 8Zi oscilloscopes | Zi-FrontPanel Removable front panel for WavePro 7Zi and WaveMaster 8Zi Oscilloscopes | Rise-Time-Filter-100ps PSPL Rise Time Filter - PSPL Part Number 5915-110-100ps | Rise-Time-Filter-150ps PSPL Rise Time Filter - PSPL Part Number 5915-110-150ps | 20dB-SMA-Attenuator 20 dB SMA Attenuators | OC1024-A Oscilloscope Cart with additional shelf and drawer | OC1021-A Oscilloscope Cart | OC910 Deluxe Oscilloscope Cart for LabMaster 9 Zi-A or LabMaster 10 Zi | Other Software Options | WM8Zi-SPECTRUM Spectrum Analyzer and Advanced FFT Option for WaveMaster 8 Zi Series | WM8Zi-EMC EMC Pulse Parameter Software Package for WaveMaster 8 Zi Series | Data Storage Software | WM8Zi-AORM Advanced Optical Recording Measurement Package for WaveMaster 8 Zi Series | WM8Zi-DDM2 Disk Drive Measurements Software Package for WaveMaster 8 Zi Series | WM8Zi-DDA Disk Drive Analyzer Software Package for WaveMaster 8 Zi Series | Remote Control/Network Options | GPIB-2 IEEE 488 GPIB Interface | USB2-GPIB External USB 2.0 to GPIB IEEE 488.2 adapter | Power Analysis Software | WM8Zi-PWR Power Analysis Option for WM 8 Zi | Digital Filtering Software | WM8Zi-DFP2 Digital Filter Software Package for WaveMaster 8 Zi Series | Mixed Signal Solutions | MS-500 500 MHz, 18 Channels, 2 GS/s, 50 Mpts/ch Mixed Signal Oscilloscope Option | MS-500-36 250 MHz,36 Ch,1 GS/s,25 Mpts/ch (500MHz,18 Ch,2 GS/s,50 Mpts/ch Interleaved) Mixed Signal Option | MS-250 250 MHz, 18 Channels, 1 GS/s, 10 Mpts/ch Mixed Signal Oscilloscope Option | Mixed Signal Accessories | PK400-1 Large Gripper Probe Set for 0.10 inch (2.54mm) pin pitch. Includes 10 probes with color coded leads | PK400-2 Medium Gripper Probe Set for 0.04 inch (1.0mm) pin pitch. Includes 10 probes with color coded leads | PK400-3 Small Gripper Probe Set for 0.008 inch (0.2 mm) pin pitch. Includes 10 probes with color coded leads | MSO-MICTOR 36 Channel Mictor Connector for MS Series (Includes 1 MSO-MICTOR-SHROUD) | MSO-3M 18 Pin 3M Interface cable MSO-3M (Mates with 3M part number 2520-6002) | MSO-DLS-36 16" Digital Lead Set, D18-D35 | MSO-MICTOR-SHROUD Shroud for MSO-MICTOR connector, Kit of 3 | Serial Data Test Fixtures | TF-ENET-B 10/100/1000BaseT Ethernet Test Fixture | TF-HDMI-3.3V-QUADPAK HDMI Pull-Up Terminator Quad Pack - For Use with the Wilder-Tech HDMI-TPA-P Plug Test Adapter | TF-SATA-C-Kit SATA Compliance Test Kit | TF-USB-B USB 2.0 Compliance Test Fixture |
Differential Probes (3-6 GHz) | D600A-AT WaveLink D600 6 GHz/4.8Vp-p Differential Amplifier Module with Adjustable Tips. | D300A-AT WaveLink D300 3 GHz/4.8Vp-p Differential Amplifier Module with Adjustable Tips. | Dx10-SI Replacement Solder tip lead set for D410/D610 | Dx20-SI Replacement Solder tip lead set for D420/D620 | D610 WaveLink D610 6 GHz/2.5Vp-p and +/-3V Offset Range Differential AmplifierSmall Tip Module with Solder-in, Quick Connect, and Square Pin Lead Sets, plus accessories. | D620 WaveLink D620 6 GHz/5Vp-p and +/-3V Offset Range Differential AmplifierSmall Tip Module with Solder-in, Quick Connect, and Square Pin Lead Sets, plus accessories. | Dx10-PT-KIT WaveLink Dx10-PT Adjustable Positioner Tip Kit. Includes XYZ Positioner Assembly with MechanicalInterconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins(Qty. 4)/Sockets(Qty 2). | Dx20-PT-KIT WaveLink Dx20-PT Adjustable Positioner Tip Kit. Includes XYZ Positioner Assembly with MechanicalInterconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins(Qty. 4)/Sockets(Qty. 2). | D410 WaveLink D410 4 GHz/2.5Vp-p and +/-3V Offset Range Differential AmplifierSmall Tip Module with Solder-in, Quick Connect, and Square Pin Lead Sets, plus accessories. | D420 WaveLink D420 4 GHz/5Vp-p and +/-3V Offset Range Differential AmplifierSmall Tip Module with Solder-in, Quick Connect, and Square Pin Lead Sets, plus accessories. | EZ Probe Cascade Microtech EZ-Probe Positioner | D410-PS 4 GHz Complete Probe System with Dx10-SI Solder-In Tip (Qty. 1), Dx10-QC Quick Connect (Qty. 1),Dx10-SP Square Pin (Qty. 1), and Dx10-PT-KIT Positioner Tip Browser (Qty. 1) | D420-PS 4 GHz Complete Probe System with Dx20-SI Solder-In Tip (Qty. 1), Dx20-QC Quick Connect (Qty. 1),Dx20-SP Square Pin (Qty. 1), and Dx20-PT-KIT Positioner Tip Browser (Qty. 1) | D610-PS 6 GHz Complete Probe System with Dx10-SI Solder-In Tip (Qty. 1), Dx10-QC Quick Connect (Qty. 1),Dx10-SP Square Pin (Qty. 1), and Dx10-PT-KIT Positioner Tip Browser (Qty. 1) | D620-PS 6 GHz Complete Probe System with Dx20-SI Solder-In Tip (Qty. 1), Dx20-QC Quick Connect (Qty. 1),Dx20-SP Square Pin (Qty. 1), and Dx20-PT-KIT Positioner Tip Browser (Qty. 1) | WL-PLINK-CASE WaveLink ProLink Platform/Cable Assembly Kit for D610, D620, D600A-AT, and Dxx30 WaveLink Probes. | WL-PBUS-CASE WaveLink ProBus Platform/Cable Assembly Kit for D410, D420, and D300A-AT WaveLink Probes. | Dx10-HiTemp WaveLink Temperature Extension cables for Dx10.Includes 1 set of matched 30" high temperature cables, 1 solder tip lead set | Dx20-HiTemp WaveLink Temperature Extension cables for Dx20.Includes 1 set of matched 30" high temperature cables, 1 solder tip lead set | TF-DSQ Probe Deskew and Calibration Test Fixture Limited Availability | Active Voltage Probes | HFP2500 2.5 GHz, 0.7pF Active Voltage Probe(10:1), Small Form Factor | ZS1500-QUADPAK Set of 4 ZS1500, 1.5 GHz High Impedance Active Probes | ZS1000-QUADPAK Set of 4 ZS1000, 1 GHz High Impedance Active Probes | ZS1500 1.5 GHz, .9 pF, 1 MOhm Active Voltage Probe | ZS1000 1 GHz, .9 pF, 1 MOhm Active Voltage Probe | ZS2500 2.5 GHz, .9 pF, 1 MOhm Active Voltage Probe | ZS2500-QUADPAK Set of 4 ZS2500, 2.5 GHz High Impedance Active Probes | Differential Probes (<= 1.5 GHz) | AP033 500 MHz Differential Probe | AP034 1 GHz, Active Differential Probe (÷1, ÷10, ÷20) | ZD200 200 MHz, 3.5 pF, 1 MOhm Active Differential Probe, ±20 V | ZD500 500 MHz, 1.0 pF Active Differential Probe, ±8 V | ZD1000 1 GHz, 1.0 pF Active Differential Probe, ±8 V | ZD1500 1.5 GHz, 1.0 pF Active Differential Probe, ±8 V | Current Probes | AP015 30 A, 50 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse | DCS015 Deskew Calibration Source for AP015 | CP150 150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse | CP500 500 A, 2 MHz Current Probe - AC/DC, 500 A rms, 700 A Peak Pulse | CP030 30A, 50MHz Current Probe | CP031 30A, 100MHz Current Probe | High Voltage Probes | PPE1.2KV 10:1/100:1 200/300 MHz 50 MOhms High-Voltage Probe 600V/1.2kV Max. Volt. DC | PPE20KV 1000:1 100 MHz 100 MOhms High-Voltage Probe 20kV Max. Volt. DC + 40kVPeak AC | PPE2KV 100:1 400 MHz 50 MOhms High-Voltage Probe | PPE4KV 100:1 400 MHz 50 MOhms High-Voltage Probe | PPE5KV 100:1 400 MHz 50 MOhms High-Voltage Probe | PPE6KV 1000:1 400 MHz 5 MOhms/50 MOhms High-Voltage Probe | Differential Probes (13-25 GHz) | TF-DSQ Probe Deskew and Calibration Test Fixture Limited Availability | EZ Probe Cascade Microtech EZ-Probe Positioner | DXX05-SI Replacement Dxx05-SI 13-25 GHz Solder-In Lead with Qty. 5 Spare Resistors. | Dxx05-PT-KIT WaveLink Dxx05-PT (up to 22 GHz rating) Adj. Positioner Tip Kit.For use with Dxx05-A amplifiers. | LPA-2.92 ProLink to 2.92mm Adapter with Probe Power and Communication Pass Through | D1305-A WaveLink D1305 13 GHz/2.0Vp-p Differential Probe Amplifier with Dxx05-SI Solder-In Tip (Qty. 2) | D1605-A WaveLink D1605-A 16 GHz/2.0Vp-p Differential Probe Amplifier with Dxx05-SI Solder-In Tip (Qty. 2) | D2005-A WaveLink D2005-A 20 GHz/2.0Vp-p Differential Probe Amplifier with Dxx05-SI Solder-In Tip (Qty. 2) | D2505-A WaveLink D2505-A 25 GHz/2.0Vp-p Differential Probe Amplifier with Dxx05-SI Solder-In Tip (Qty. 2) | D1305-A-PS 13 GHz Complete Probe System with Solder-In Tip (13 GHz) and Positioner Tip Browser (13 GHz) | D1605-A-PS 16 GHz Complete Probe System with Solder-In Tip (16 GHz) and Positioner Tip Browser (16 GHz) | D2005-A-PS 20 GHz Complete Probe System with Solder-In Tip (20 GHz) and Positioner Tip Browser (20 GHz) | D2505-A-PS 25 GHz Complete Probe System with Solder-In Tip (25 GHz) and Positioner Tip Browser (22 GHz) | D1305-A-CCNIST NIST Calibration for D1305-A. Includes test data. | D1605-A-CCNIST NIST Calibration for D1605-A. Includes test data. | D2005-A-CCNIST NIST Calibration for D2005-A. Includes test data. | D2505-A-CCNIST NIST Calibration for D2505-A. Includes test data. | WL-PLINK-A-CASE WaveLink ProLink Platform/Cable Assembly Kit for Dxx05-A 13-20 GHz WaveLink Probes. | WL-2.92MM-CASE WaveLink 2.92mm Platform/Cable Assembly Kit for D2505-A 25 GHz WaveLink Probes. | High Voltage Differential Probes | AP031 700 V, 15 MHz High-Voltage Differential Probe (÷10, ÷100) | ADP300 1,400 V, 20 MHz High-Voltage Differential Probe | ADP305 1,400 V, 100 MHz High-Voltage Differential Probe | Transmission Line Probes | PP065 100:1 1 GHz 5 KOhms Passive Probe | PP066 7.5 GHz low capacitance Passive Probe, 500/1K Ohms | Optical Probes | OE425 Optical-to-Electrical Converter, 500-870 nm ProBus BNC Connector | OE455 Optical-to-Electrical Converter, 950-1630 nm ProBus BNC Connector | OE525 Optical-to-Electrical Converter, 500-870 nm ProLink BMA Connector | OE555 Optical-to-Electrical Converter, 950-1630 nm ProLink BMA Connector | OE695G Optical to Electrical Converter | Differential Amplifiers | DA1855A 1 Ch, 100 MHz Differential Amplifier with Precision Voltage Source | DXC100A ÷100 or ÷10 Selectable, 250 MHz Passive Differential Probe Pair | DXC200 ÷1, 50 MHz, Passive Differential Probe Pair | DXC-5100 100:1 250 MHz 10 Mohm 2.75pf Differential Probe Pair; | DA101 10:1 1 MOhm Passive Attenuator | DA1855A-PR2 2 Ch, 100 MHz, Differential Amplifier with Precision Voltage Source | DA1855A-PR2-RM 2 Ch, DA1855A with Rackmount (must be ordered at time of purchase, no retrofit) | DA18000AC 18 GHz Differential Amplifier (for SDA 18000 only) Limited Availability | DA1855A-RM DA1855A with rackmount; | Probe Parts and Kits | LPA-SMA-A Pro-Link to SMA Adapter, new style | LPA-SMA-KIT-A Kit of Pro-Link to SMA Adapter, new style | LPA-K-A Pro-Link to K/2.92mm Adapter | LPA-K-KIT-A Kit of Qty. 4 Pro-Link to K/2.92mm Adapter | Dx10-HiTEMP WaveLink Temperature Extension cables for Dx10.Includes 1 set of matched 30" high temperature cables, 1 solder tip lead set | Dx20-HiTEMP WaveLink Temperature Extension cables for Dx20.Includes 1 set of matched 30" high temperature cables, 1 solder tip lead set | Dx10-SI-HiTEMP Replacement Solder tip leadset for use with D410/D610 and temperature extension cables | Dx20-SI-HiTEMP Replacement Solder tip leadset for use with D420/620 and temperature extension cables | Dxx0-Cable-HiTemp Replacement 30" matched cable set for use with HiTemp Solder tip leadset | OE695G-REFCAL OE695G Reference Cal (1ch) | Differential Probes (8-13 GHz) | D830 WaveLink D830 8 GHz/3.5Vp-p Differential Probe Amplifier with Dxx30-SI Solder-In Tip (Qty. 2) andDxx30-SP Square Pin (Qty. 1) | D1030 WaveLink D1030 10 GHz/3.5Vp-p Differential Probe Amplifier with Dxx30-SI Solder-In Tip (Qty. 2)and Dxx30-SP Square Pin (Qty. 1). | D1330 WaveLink D1330 13 GHz/3.5Vp-p Differential Probe Amplifier with Dxx30-SI Solder-In Tip (Qty. 2)and Dxx30-SP Square Pin (Qty. 1) | D830-PS 8 GHz Complete Probe System with Dxx30-SI Solder-In Tip (Qty. 2), Dxx30-SP Square Pin (Qty. 1),and Dxx30-PT-KIT Positioner Tip Browser (Qty. 1) | D1030-PS 10 GHz Complete Probe System with Dxx30-SI Solder-In Tip (Qty. 2), Dxx30-SP Square Pin (Qty. 1),and Dxx30-PT-KIT Positioner Tip Browser (Qty. 1) | D1330-PS 13 GHz Complete Probe System with Dxx30-SI Solder-In Tip (Qty. 2), Dxx30-SP Square Pin (Qty. 1),and Dxx30-PT-KIT Positioner Tip Browser (Qty. 1) | WL-PLINK-CASE WaveLink ProLink Platform/Cable Assembly Kit for D610, D620, D600A-AT, and Dxx30 WaveLink Probes. | Dxx30-PT-KIT WaveLink Dxx30-PT (up to 10 GHz rating) Adjustable Positioner Tip Kit. For use with Dxx30 amplifiers | DXX30-SMA-SMP-LEADS Lead set consisting of WaveLink Dxx30-SMA-SMP-LEADS for use with Dxx30 amplifiers. | D830-CCNIST NIST Calibration for D830. Includes test data. | D1030-CCNIST NIST Calibration for D1030. Includes test data. | D1330-CCNIST NIST Calibration for D1330. Includes test data. | EZ Probe Cascade Microtech EZ-Probe Positioner | Dxx30-SI Replacement Dxx30-SI 8-13 GHz Solder-In Lead with Qty. 5 Spare Resistors. | TF-DSQ Probe Deskew and Calibration Test Fixture Limited Availability |
|
|
|