Products
Oscilloscope Probes

HVD3106A-6M

1kV, 80 MHz High Voltage Differential Probe with 6m cable and Auto Zero Disconnect


    High Voltage Differential Probes


HVD3102A - 1kV, 25 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3102A-NOACC - 1kV, 25 MHz High Voltage Differential Probe without tip Accessories and with Auto Zero Disconnect
HVD3106A - 1kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3106A-NOACC - 1kV, 120 MHz High Voltage Differential Probe without tip Accessories and with Auto Zero Disconnect
HVD3106A-6M - 1kV, 80 MHz High Voltage Differential Probe with 6m cable and Auto Zero Disconnect
HVD3206A - 2kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3206A-6M - 2kV, 80 MHz High Voltage Differential Probe with 6m cable and Auto Zero Disconnect
HVD3605A - 6kV, 100 MHz High Voltage Differential Probe with Auto Zero Disconnect
AP031 - 700 V, 25 MHz High-Voltage Differential Probe (÷10, ÷100)
ADP300 - 1kV, 20 MHz High-Voltage Differential Probe Limited Availability
ADP305 - 1kV, 100 MHz High-Voltage Differential Probe Limited Availability

The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.

Device Under TestRecommended ModelSafety ClassBandwidthCable LengthTip Accessories Included
120 V/240 V Half-Bridge Circuit Topologies HVD3102A1 kV25 MHz2 mYes
HVD3102A-NOACC1 kV25 MHz2 mNo
HVD3106A1 kV120 MHz2 mYes
HVD3106A-NOACC1 kV120 MHz2 mNo
380 V - 600 V Class Electrical ApparatusHVD3106A1 kV120 MHz2 mYes
HVD3106A-NOACC1 kV120 MHz2 mNo
HVD3106A-6M1 kV80 MHz6 mYes
Solar PV InverterHVD3106A1 kV120 MHz2 mYes
HVD3206A1.5 kV120 MHz2 mYes
HVD3206A-6M1.5 kV80 MHz6 mYes
5 kV Electrical ApparatusHVD3605A6 kV100 MHz6 mYes
Key Features
  • 1 kV, 2 kV, 6 kV CAT safety rated models
  • Widest differential voltage ranges available
  • Exceptional common-mode rejection ratio (CMRR) across a broad frequency range
  • 1% gain accuracy
  • High offset capability at both high and low attenuation
  • AC and DC coupling
  • ProBus active probe interface with automatic scaling
  • AutoZero with auto disconnect switch
  • Wide oscilloscope compatibility

 

Exceptional Common-Mode Rejection Ratio

The CMRR for the probes is exceptional out to very high frequencies, greatly improving measurement capability in the noisy, high common-mode environments found in power electronics. The high CMRR combined with low probe noise and high offset capability provides superior measurement capabilities compared to other HV differential probes.

High Precision Measurements

HVD3000A series probes provide 1% gain accuracy enabling precise voltage measurements. AutoZero capability ensures further measurement precision by allowing small offset drifts to be calibrated out of the measurement. This feature can be applied without removing the HVD3000A leads from the device under test.

Widest Application Coverage

The HVD3000A series cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV class electrical apparatus. Each model has the best available gain accuracy, widest differential and offset voltage range, and superior CMRR.

1500 Vdc CAT III Rating

The HVD3206A supports 1500 Vdc solar photovoltaic (PV) measurements per the IEC/EN 61010- 031:2015 standard. It has a 1500 Vdc CAT III and a 2000 V (DC+peakAC) CAT I rating.

Complete Probe Integration

The ProBus interface provides power and communication to the probe eliminating the need for a separate power supply or batteries. Attenuation is automatically selected based on oscilloscope gain range (V/div) setting.

Main Specifications

Bandwidth 80 MHz
Input Coupling DC only
Input Impedance 10 MΩ || 2.5 pF (between inputs)
5 MΩ || 5.0 pF (either input to ground)
Attenuation 50x / 500x
Rise Time
(10-90%)
4.4 ns
Differential Voltage Range (High Attenuation) 1500 V (DC + peak AC) from 7 to 500 V/div with up to 1500V offset.
2000 V maximum typical measurable differential voltage before saturation
Differential Voltage Range (Low Attenuation) 27.6 V (DC + peak AC) from 100 mV/div to 6.9 V/div with up to 150V offset.
Common Mode Voltage Range ±1500 V (DC + peak AC), 1000 Vrms (CAT III) (either input to ground)
Maximum Input Voltage to Earth ±2000 Vpk (nominal, either input to ground)
Max Safe Input 1000 Vrms CAT III
per IEC/EN 61010-031/A1:2008
Sensitivity 100 mV/div to 6.9V/div (50X)
7V/div to 500V/div (500X)
Gain Accuracy 1% (LF, guaranteed)
Slew Rate 400 V/ns (maximum)
Output Coupling AC or DC coupling
Output Termination 1 MΩ
Interface ProBus
Input Lead Length 40 cm input lead length
Cable Length (input lead to oscilloscope connection) 6.80 m
 

Noise and Rejection

CMRR (Typical) DC - 60 Hz: 85 dB
1 MHz: 65 dB
5 MHz: 40 dB
20 MHz: 30 dB
80 MHz: 30 dB
Noise (Probe) 50X: <30 mVrms
500X: <150 mVrms
(referred to input)
 

Environmental and Safety

Temperature (Operating) 0°C to 50°C
Temperature (Non-Operating) -40°C to 70°C
Humidity (Operating) 5% to 80% RH (Non-Condensing) up to 30°C, decreasing linearly to 45% RH at 50°C
Humidity (Non-Operating) 5% to 95% RH (Non-Condensing), 75% RH above 30°C, 45% RH above 40°C
Altitude (Operating) 3,000 m maximum
When used with clip accessories, 2000 m maximum
Altitude (Non-Operating) 10,000 m
Pollution Degree 2, Indoor use only
 
WaveSurfer 3000z Oscilloscopes

WaveSurfer 3000z Oscilloscopes
   Learn More
WaveSurfer 10 Oscilloscope

WaveSurfer 10
   Learn More
WaveSurfer 510 Oscilloscope

WaveSurfer 510
   Learn More
HDO4000A High Definition Oscilloscopes


   Learn More
WaveRunner 8000 Oscilloscopes


   Learn More
HDO6000A High Definition Oscilloscopes


   Learn More
HDO8000A High Definition Oscilloscopes


   Learn More
MDA800A Motor Drive Analyzers


   Learn More
WavePro HD Oscilloscopes

WavePro HD Oscilloscopes
   Learn More
WaveMaster / SDA / DDA 8 Zi-B Oscilloscopes


   Learn More