Products
Oscilloscope Probes

DXC100A

Selectable 100:1 or 10:1 , Passive Differential Probe Pair


    Differential Amplifiers


DA1855A - 1 Ch, 100 MHz Differential Amplifier with Precision Voltage Source
DXC100A - ÷100 or ÷10 Selectable, 250 MHz Passive Differential Probe Pair
DXC200 - ÷1, 50 MHz, Passive Differential Probe Pair
DXC-5100 - 100:1 250 MHz 40 Mohm 2.75pf Differential Probe Pair;
DA101 - 10:1 1 MOhm Passive Attenuator
DA1855A-PR2 - 2 Ch, 100 MHz, Differential Amplifier with Precision Voltage Source
DA1855A-PR2-RM - 2 Ch, DA1855A with Rackmount (must be ordered at time of purchase, no retrofit)
DA1855A-RM - DA1855A with rackmount;
Differential amplifiers are intended to act as signal conditioning preamplifiers for oscilloscopes and network and spectrum analyzers, providing differential measurement capability to instruments having only a single-ended input. The "-PR2" version of each amplifier is a dual channel unit. The DXC series differential input cables are matched to the characteristics of the amplifier.
Model DXC100A
Main Features
  • DC to 100 MHz Bandwidth with DA1855A DC to 10 MHz Bandwidth with DA1822
  • Max Input Voltage 500 V
  • Selectable 10 or 100 Attenuation Factor
  • 1.2 Meter Cable Length

The DXC100A is a high-performance, passive, matched, differential probe pair designed for use with the DA1800 series differential amplifiers. The probe pair consists of two highly matched individual probes that share a common compensation box to allow the attenuation factor on both probes to be simultaneously switched between 10x and 100x. When used with the DA1822 or DA1855A differential amplifier, the probe''s attenuation factor is automatically incorporated into the effective gain display, and the location of the decimal into the voltage generator display. Although primarily designed for use with the amplifiers, the DXC100A differential probe pair can be used with any oscilloscope or plug-in unit with an input impedance of 1 M(omh)/15-26 pF and one inch (25.4 mm) spacing between connectors. When used on a differential amplifier, the DXC100A compensation box allows for precise adjustment and matching of the transient response and optimization of the system Common Mode Rejection Ratio (CMRR).

Specifications
General
Attenuation factor: 10 or 100
Bandwidth (-3 dB): 250 MHz
System Bandwidth: (-3 dB) (with DA1855):100 MHz
(with DA1822): 10 MHz
System Risetime  (with DA1855): 3.5 ns
(with DA1822): 35 ns
Input Resistance: 1 MΩ ±1%
Input Capacitance: 10.5 pF ±0.5 pF
Compensation Range:  15 to 26 pF
Maximum non-destructive Input Voltage: 500 VDC + peak AC
Length: 1.2 meter
Environmental Characteristics
Operating Range: 0° to 50°C
Non-Operating: -4° to 75°*C
Physical Characteristics
Weight:0.21 kg (0.47 lb)
Shipping Weight: 0.45 kg (1 lb)
Warranty:1 year

Main Specifications

Bandwidth (-3 dB) : 250 MHz
 

Electrical Characteristics

Risetime (typical) (with DA1850/DA1855) : 3.5 ns (with DA1820/DA1822) : 35 ns
 

WaveSurfer 10 Oscilloscope

WaveSurfer 10
  Learn More
WaveSurfer 510 Oscilloscope


  Learn More
HDO4000A High Definition Oscilloscopes


  Learn More
WaveRunner 8000 Oscilloscopes


  Learn More
HDO6000A High Definition Oscilloscopes


  Learn More
HDO8000A High Definition Oscilloscopes


  Learn More
MDA800A Motor Drive Analyzers


  Learn More
WaveMaster / SDA / DDA 8 Zi-B Oscilloscopes


  Learn More