Products
Oscilloscope Probes
product intro image

PP007-WS-1

÷10 HiZ 500 MHz Passive Probe for WaveSufer 400 Series Oscilloscopes.


  • product line tab
  • overview tab
  • product detail tab
  • specs tab
  • accessories tab

    Passive Probes


PP005A - 10:1 500MHz 10 MOhms CATII
PP006D - 500 MHz Passive Probe for WaveJet Touch, 10:1, 10 MOhm
T3PP350 - T3DSO Passive Probe, 350 MHz, 10:1, 1 MOhm/10 MOhm, 300Vrms CAT II
PP007-WS-1 - 10:1 500 MHz 10 M Passive Probe
PP007-WR-1 - 10:1 500 MHz 10 M Passive Probe
PP008-1 - 500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP009-1 - 500 MHz passive probe, 10: 1 (for WaveSurfer Xs), mechanically identical to PP005A
PP011-1 - 500 MHz passive probe, 10: 1 (for WSXs 1GHz), mechanically identical to PP005A
PP016 - 10:1, 10 Mohm, 300 MHz Passive Probe
PP017-1 - 250 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP018-1 - 500 MHz Passive Probe for HDO, 10:1, 10 MOhm
PP019-1 - 250 MHz Passive Probe for WaveSurfer 3000, 10:1, 10 MOhm
PP020-1 - 500 MHz Passive Probe for WaveSurfer 3000, 10:1, 10 MOhm
PP021-1 - 500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1 - 500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP023-1 - 500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP024-1 - 500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP025-1 - 500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP026-1 - 500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
Passive Probes

Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.

Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

Oscilloscope Series Model Bandwidth Input R Input C Attenuation Maximum
Voltage
Diameter
9300 Series PP005A 500 MHz 10 MΩ 11 pF 10:1 600 V 5 mm
HDO4000A Series
(200 MHz)
PP017 200 MHz 10 MΩ 12 pF 10:1 350 V 5 mm
PP023 500 MHz 10 MΩ 10 pF 10:1 500 V 2.5 mm
PP026 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
HDO4000A Series
(>=350 MHz)
PP018 500 MHz 10 MΩ 10 pF 10:1 350 V 5 mm
PP023 500 MHz 10 MΩ 10 pF 10:1 500 V 2.5 mm
PP026 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
HDO6000B Series PP023 500 MHz 10 MΩ 10 pF 10:1 500 V 2.5 mm
PP026 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
HDO6000A Series PP018 500 MHz 10 MΩ 10 pF 10:1 350 V 5 mm
PP023 500 MHz 10 MΩ 10 pF 10:1 500 V 2.5 mm
PP026 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
HDO8000A Series PP018 500 MHz 10 MΩ 10 pF 10:1 350 V 5 mm
PP023 500 MHz 10 MΩ 10 pF 10:1 500 V 2.5 mm
PP026 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
MDA 8000HD Series PP025 500 MHz 10 MΩ 11 pF 10:1 500 V 5 mm
MDA800A Series PP018 500 MHz 10 MΩ 10 pF 10:1 350 V 5 mm
PP023 500 MHz 10 MΩ 10 pF 10:1 500 V 2.5 mm
PP026 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
HDO9000 Series PP022 500 MHz 10 MΩ 10 pF 10:1 500 V 2.5 mm
PP024 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
LC Series PP005A 500 MHz 10 MΩ 11 pF 10:1 600 V 5 mm
PP006D 500 MHz 10 MΩ 12 pF 10:1 350 V 5 mm
WaveAce Series
(200 MHz)
PP016 300 MHz
10 MHz
10 MΩ
1 MΩ
12 pF
46 pF
10:1
1:1
600 V 5 mm
WaveJet(A) Series
(= 350 MHz)
PP006D 500 MHz 10 MΩ 12 pF 10:1 350 V 5 mm
WaveJet Touch PP006D 500 MHz 10 MΩ 12 pF 10:1 350 V 5 mm
WaveMaster 8 Zi(A, B) Series PP007-WR 500 MHz 10 MΩ 9.5 pF 10:1 400 V 2.5 mm
PP011 500 MHz 10 MΩ 9.5 pF 10:1 400 V 5 mm
PP025 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
WavePro 7 Zi(A) Series PP007-WR 500 MHz 10 MΩ 9.5 pF 10:1 400 V 2.5 mm
PP011 500 MHz 10 MΩ 9.5 pF 10:1 400 V 5 mm
PP025 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
WavePro 7000 Series PP005A 500 MHz 10 MΩ 11 pF 10:1 600 V 5 mm
WavePro 900 Series PP005A 500 MHz 10 MΩ 11 pF 10:1 600 V 5 mm
WavePro HD Series PP023 500 MHz 10 MΩ 10 pF 10:1 500 V 2.5 mm
PP026 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
WaveRunner 8000HD Series PP025 500 MHz 10 MΩ 11 pF 10:1 500 V 5 mm
WaveRunner 8000/9000 Series PP022 500 MHz 10 MΩ 10 pF 10:1 500 V 2.5 mm
PP024 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
WaveRunner 6 Zi Series PP008 500 MHz 10 MΩ 9.5 pF 10:1 400 V 2.5 mm
PP009 500 MHz 10 MΩ 9.5 pF 10:1 400 V 5 mm
PP022 500 MHz 10 MΩ 10 pF 10:1 500 V 2.5 mm
PP024 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
WaveRunner 6000(A) Series PP007-WR 500 MHz 10 MΩ 9.5 pF 10:1 400 V 2.5 mm
PP011 500 MHz 10 MΩ 9.5 pF 10:1 400 V 5 mm
PP025 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
WaveRunner Xi(A)
(1 GHz - 2 GHz)
PP007-WR 500 MHz 10 MΩ 9.5 pF 10:1 400 V 2.5 mm
PP011 500 MHz 10 MΩ 9.5 pF 10:1 400 V 5 mm
PP025 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
WaveRunner Xi(A) Series
(<= 600 MHz)
PP008 500 MHz 10 MΩ 9.5 pF 10:1 400 V 2.5 mm
PP009 500 MHz 10 MΩ 9.5 pF 10:1 400 V 5 mm
PP022 500 MHz 10 MΩ 10 pF 10:1 500 V 2.5 mm
PP024 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
WaveSurfer 4000HD Series PP019 200 MHz 10 MΩ 12 pF 10:1 500 V 5 mm
PP026 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
WaveSurfer 3000/3000z Series PP019 200 MHz 10 MΩ 12 pF 10:1 500 V 5 mm
PP020 500 MHz 10 MΩ 11 pF 10:1 500 V 5 mm
WaveSurfer 400 Series PP007-WS 500 MHz 10 MΩ 9.5 pF 10:1 400 V 2.5 mm
PP008 500 MHz 10 MΩ 9.5 pF 10:1 400 V 2.5 mm
PP009 500 MHz 10 MΩ 9.5 pF 10:1 400 V 5 mm
PP022 500 MHz 10 MΩ 10 pF 10:1 500 V 2.5 mm
PP024 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
WaveSurfer 510 Series PP024 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
WaveSurfer Xs(A,B) Series
(<= 600 MHz)
PP008 500 MHz 10 MΩ 9.5 pF 10:1 400 V 2.5 mm
PP009 500 MHz 10 MΩ 9.5 pF 10:1 400 V 5 mm
PP022 500 MHz 10 MΩ 10 pF 10:1 500 V 2.5 mm
PP024 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm
WaveSurfer Xs(A,B) Series
(1 GHz)
PP007-WR 500 MHz 10 MΩ 9.5 pF 10:1 400 V 2.5 mm
PP011 500 MHz 10 MΩ 9.5 pF 10:1 400 V 5 mm
PP025 500 MHz 10 MΩ 10 pF 10:1 500 V 5 mm

 

Leading Features
  • Compact probe head
  • Supports fine pitch SMD probing
  • Rugged, sharp tip
  • HF optimized connection accessories
  • Over 30 accessories
  • Low input capacitance

Updated Passive Probe
The PP007 embodies leading technology in passive probe design. The small probe is optimized for maximum waveform fidelity, including high frequency signal components, in a rugged probe suitable for every day.

The sharp probe tip* is spring loaded, allowing it to retract into the narrow probe head. The tip does not slip off the object being probed—important when probing small geometry surface-mounted components. Probing dense circuits is easier with the small 2.5 mm ground sleeve, which provides much better visibility than 5 mm and 3.5 mm probes.
* A rigid tip is also available

Optimized for HF Applications
The input capacitance of the probe is very low for a passive probe—to minimize loading of high frequency signals. However, keeping any resonance beyond the passband also requires low inductance in the interconnections. Probes with limited interconnection accessories often force the user to extend the input or ground lead lengths to connect to the circuit—a practice that adds inductance and lowers the resonate frequency.

Accessories such as the ground spring and innovative ground blade (PK007-013) provide a very low inductance ground interconnect. Copper foil tape, (PK007-014) included with the probe, can be placed on top of an IC and connected to its ground pins to create a convenient ground plane for the probe to connect to. Used with the ground blade, this method provides an ideal ground connection for probing signals with high frequency content.

For applications which require the flexibility of a longer ground lead without compromising high frequency performance, the optional HF-compensated ground lead (PK007-030) provides a solution. A passive network in the lead itself reduces the loading effect of any resonance.

Ease in Probing SMT Circuits
In addition to the small probe head size, the PP007 is augmented with several accessories to simplify probing dense surface mounted circuit assemblies. Insulating probe caps with guide fingers (PK007-009, 010, 011, 012) keep the small probe tip centered on the IC lead and prevent it from shorting to adjacent leads. The IC Caps are supplied in a range of sizes designed for IC lead pitches from 0.5 mm through 1.27 mm.

Optional accessory kits contain 0.5 mm micro clips for attaching to the smallest IC leads, along with adapter leads to connect to the probe tip.

Rugged Probe for Everyday Use
Unlike some probes, the PP007 does not trade off physical robustness to obtain excellent high frequency performance. The probe will stand up to the rigors of everyday use.

The probe has a working voltage rating of 400VCAT I with transient surges up to 1250 V.

EN61010-31-2 Installation category I (CAT I) is for probing circuits which are isolated from the power mains through a power supply transformer—the most common circuits measured with oscilloscopes. The probe also is rated fora CAT II working voltage of 300 V.CAT II circuits are on the primary side of power converters and similar power line connected circuits which are not intended to be permanently connected to building wiring.

The probe tip is mounted in a socket, allowing user replacement should it ever break.

Ordering the Correct Model
The PP007 is supplied in two models, each optimized to give the best performance with a specific family of oscilloscope. The PP007-WR is designed to be used with the WaveRunner 6000 series, while the PP007-WS is designed for the WaveSurfer 400 series oscilloscopes. The physical design of the probes are identical. All of the connection accessories, standard and optional, will fit both models.

Electrical Characteristics

Bandwidth (Probe Only) 500 MHz
Input Resistance 10 MΩ
Input Capacitance 9.5 pF
Maximum Input Voltage 400 V
Attenuation 10:1
Coupling AC 1 MΩ, DC 1MΩ, GND
 

Environmental and Safety

Operating Temperature 0 °C to 50 °C
(32 °F to 122 °F)
Storage Temperature -40 °C to 71 °C
(-40 °F to 160 °F)
Max Altitude 2000 m
(6562 ft)
 

Physical Dimensions

Probe Diameter 2.5 mm
Cable Length 1.2 m
(3.94 ft)
 

General Characteristics

Interface BNC
Attenuation Sense Pin Yes
Recommended Oscilloscope WaveSurfer 400