SPARQ Series Signal Integrity Network Analyzers - Time Domain Analysis

Problem:

What is the "Rise" selector that becomes visible when selecting to view a time domain response result types? (step, impulse, Z or Rho)

Solution:

The "Rise" selector contains the rise time value to use for the raised-cosine step used to simulate the time domain result. (For more information, see the FAQ "How does the SPARQ measure time domain responses?")