ABSOLUTE MAXIMUM RATINGS (above which useful life may be impaired)

Positive Supply Voltage

7 V

Negative Supply Voltage

-4 V

Current at Amplifier Input

±10 mA

Differential Input Current

±10 mA

Maximum Continuous Power Dissipation (at 50°C still air)

0.75 W

Storage Temperature

-65 to +150°C
RECOMMENDED OPERATING CONDITIONS
Symbol Minimum Maximum Unit

Positive Supply Voltage

VCC 3 5 V

Negative Supply Voltage

VEE -2 -3.5 V

Operating Temperature (still air)

TA - 50 °C

Operating Temperature (Air Flow 500 LFM)

TFA - 75 °C

Output Signal Current

Imax - 20 mA
ELECTRICAL CHARACTERISTICS
Measured at T = 25°C, VCC = +5.0 V, VEE = -2.5 V with AC coupled outputs and a load of 50 paralleled by 5 pF unless otherwise specified, for a package thermal resistance of 90°C/W. See test setup (Figure 1).

PARAMETERS

Symbol Minimum Typical Maximum Unit

Positive Supply Current

ICC - 40 50 mA

Negative Supply Current

IEE - -25 30 mA

Quiescent Input Voltage

VQI -0.85 -0.65 -0.55 V

Input Noise (Note 1)

IN - 65 100 nA

Input Resistance

RI 65 85 100

Input Resistance Stability

DRI - 0.3 0.45 %/°C

Input Capacitance

CI - 4 6 pF

Input Protection (50 pF, 2 kV)

E 1 x 10­4 - - J

Gain (Note 2)

G 20 25 30 mV/µA

Gain Stability

DG - 0.08 0.15 mV/µA

Quiescent Output Voltage

VQO 0 0.5 1 V

Maximum Positive Output Swing

Vmax+ 1 1.5 - V

Maximum Negative Output Swing (Note 3)

Vmax- 75 150 - mV

Integral Non Linearity (Note 4)

L - 0.5 1.5 %

Output Resistance

RO 20 30 40

Propagation Delay

tPD 3 5 7 nsec

Rise Time

tR - 3 7 nsec

Fall Time

tF - 5 7 nsec
Notes
1. Noise with no external capacitance at input and with the typical noise bandwidth of 100 MHz.
2. Gain measured with a 10 µA input signal.
3. Without external pull-down resistor. Can be extended by the use of a pull-down resistor.
4. For positive output voltage swing of 1 V with a load of > 50 .