Products
Oscilloscopes
WaveRunner 8058HD Oscilloscope

WaveRunner 8058HD

500 MHz, 8 Ch, 12 bits, 10 GS/s, 50 Mpts/Ch High Definition Oscilloscope


  • product line tab
  • overview tab
  • specs tab
  • options tab
  • probes tab
WaveRunner 8038HD   (350 MHz Bandwidth, 8 Input Channels, 50 Mpts/ch, 10GS/s)
Quick Specs
Bandwidth350 MHz
Sample Rate10 GS/s on 8 Ch with ESR
Maximum Acquisition Memory5 Gpts (2 Ch operation)
Input Channels8
Vertical Resolution12 bits
WaveRunner 8058HD   (500 MHz Bandwidth, 8 Input Channels, 50 Mpts/ch, 10GS/s)
Quick Specs
Bandwidth500 MHz
Sample Rate10 GS/s on 8 Ch with ESR
Maximum Acquisition Memory5 Gpts (2 Ch operation)
Input Channels8
Vertical Resolution12 bits
WaveRunner 8108HD   (1 GHz Bandwidth, 8 Input Channels, 50 Mpts/ch, 10GS/s)
Quick Specs
Bandwidth1 GHz
Sample Rate10 GS/s on 8 Ch with ESR
Maximum Acquisition Memory5 Gpts (2 Ch operation)
Input Channels8
Vertical Resolution12 bits
WaveRunner 8208HD   (2 GHz Bandwidth, 8 Input Channels, 50 Mpts/ch, 10GS/s)
Quick Specs
Bandwidth2 GHz
Sample Rate10 GS/s on 8 Ch with ESR
Maximum Acquisition Memory5 Gpts (2 Ch operation)
Input Channels8
Vertical Resolution12 bits
Check up to three models.
Key Features
  • Highest resolution – 12 bits all the time
  • More channels, flexibility – 8 analog and 16 digital channels
  • Longest Memory – 5 Gpt records with simple navigation – no compromise
  • View 16 channels on one display with OscilloSYNC™
  • Powerful, deep toolbox enables and simplifies complex analysis
  • MAUI with OneTouch user interface for intuitive and efficient operation

 

HD4096 – 12 Bits All the Time, 16 x Closer to Perfect
Teledyne LeCroy HD4096 logo badge

Teledyne LeCroy high definition 12-bit oscilloscopes use unique HD4096 technology to provide superior and uncompromised measurement performance. HD4096 technology provides the highest resolution and lowest noise at full bandwidth—12 bits all the time with no compromise.

More Channels, More Flexibility
Two WaveRunner 8000HD 8 channel high definition oscilloscopes connected with OscilloSYNC  testing a small motor drive with the HVD Series high voltage differential probes and three CP series current probes acquiring signals from the drive output with twelve signals displayed on one oscilloscope display using also digital logic (MSO) inputs, a passive probe, a high voltage fiber optic probe, a ZS1000 single-ended active probe, and a current sensor connected to a CA10 current sensor adaptor

The WaveRunner 8000HD 8 channel oscilloscopes are the only oscilloscopes to offer 8 analog channels and 16 digital channels, allow synchronization of two 8-channel systems, and not penalize you for using a digital channel. Other oscilloscopes require that you trade a valuable analog channel in exchange for digital inputs.

16 Channels with OscilloSYNC
Two WaveRunner 8000HD 8 channel high definition oscilloscopes connected together using OscilloSYNC to provide 16 channels on one oscilloscope display

View and control 16 analog channels on a single display with OscilloSYNC technology – just like having a single 16-channel acquisition system. Setup is incredibly easy with four simple steps. The activation key can be downloaded at no charge from: teledynelecroy.com/redeem/OscilloSYNC

Longest Memory, Simple Navigation
WaveRunner 8000HD 8 channel high definition oscilloscope displaying a five gigapoint (Gpt) acquisition with a fault at the very end of the acquisition

With up to 5 Gpts of acquisition memory, WaveRunner 8000HD 8 channel, 12-bit oscilloscopes capture long periods of time, yet maintain high sample rate for visibility into the smallest details. WaveRunner 8000HD can acquire 500 ms of data at the full 10 GS/s sample rate - and always with 12 bits of resolution.

3-Phase Power Conversion Testing
WaveRunner 8000HD 8 channel high definition oscilloscope with the HVD Series high voltage differential probes and three current probes acquiring signals from a DC to AC inverter

WaveRunner 8000HD 8 channel, 12-bit oscilloscopes deliver 8 analog channels (16 with OscilloSYNC), 3-phase power analysis software, and high performance probes for inverter subsection, power system and control testing.

Automotive Electronics Testing
WaveRunner 8000HD 8 channel high definition oscilloscope performing an automotive ethernet test, displaying decoded data with an intuitive, color-coded overlay and a searchable protocol table while also showing an eye diagram of the PAM-3 automotive ethernet signal

WaveRunner 8000HD 8 channel, 12-bit oscilloscopes combine a high channel count, long memory, and wide range of validation and debug software to best address the specific test needs of the automotive industry.

Power Integrity and Power Sequencing Test
WaveRunner 8000HD 8 channel high definition oscilloscope screen capture of turn-on power sequence of eight different power rails during a fifty megapoint (Mpt) acquisition using coaxial cables and RP4030 solder-in leads 1 megohm (MΩ) coupled to the oscilloscope inputs

WaveRunner 8000HD 8 channel, 12-bit oscilloscopes' high resolution, long memory and high channel count let you validate and debug all aspects of power supply, delivery and consumption - for complete confidence.

Deeply Embedded Computing Systems Testing
WaveRunner 8000HD 8 channel high definition oscilloscope screen capture of low-speed (I2C, SPI, UART-RS232, etc.) serial data signals, decoding them, and presenting decoded data in an intuitive, color-coded overlay and in a searchable protocol table while also performing statistical analysis and displaying histograms, tracks, and eye diagrams

WaveRunner 8000HD 8 channel, 12-bit oscilloscopes acquire the longest records at the highest resolution for the most comprehensive deeply embedded computing system analysis (analog, digital, serial data and sensor).

 

 

Vertical - Analog Channels

Analog Bandwidth (Max) 500 MHz
Analog Bandwidth @ 50 Ω (-3 dB) (ProBus Input) 500 MHz
(≥1 mV/div)
Analog Bandwidth @ 1 MΩ (-3 dB) (ProBus Input) 500 MHz
Rise Time (10-90%, 50 Ω) 700 ps
Rise Time (20-80%, 50 Ω) 525 ps
Input Channels 8
Vertical Resolution 12 bits; up to 15 bits with enhanced resolution (ERES)
Effective Number of Bits (ENOB) 8.8 bits
Vertical Noise Floor (1 mV/div) 100 µVrms
Vertical Noise Floor (2 mV/div) 100 µVrms
Vertical Noise Floor (5 mV/div) 105 µVrms
Vertical Noise Floor (10 mV/div) 125 µVrms
Vertical Noise Floor (20 mV/div) 145 µVrms
Vertical Noise Floor (50 mV/div) 200 µVrms
Vertical Noise Floor (100 mV/div) 310 mVrms
Vertical Noise Floor (200 mV/div) 1.45 mVrms
Vertical Noise Floor (500 mV/div) 2.00 mVrms
Vertical Noise Floor (1 V/div) 3.15 mVrms
Sensitivity 50 Ω: 1 mV-1 V/div, fully variable;
1 MΩ: 1 mV-10 V/div, fully variable
DC Vertical Gain Accuracy (Gain Component of DC Accuracy) ±(0.5%) FS, offset at 0 V
Channel-Channel Isolation DC-200 MHz: 70 dB (>3000:1),
200-500 MHz: 60 dB (>1000:1)
(For any two input channels, same V/div settings, typical)
Offset Range 50 Ω
±1.6 V @ 1 mV - 4.95 mV/div
±4 V @ 5 mV - 9.9 mV/div
±8 V @ 10 mV - 19.8 mV/div
±10 V @ 20 mV - 1 V/div

1 MΩ
±1.6 V @ 1 mV - 4.95 mV/div
±4 V @ 5 mV - 9.9 mV/div
±8 V @ 10 mV - 19.8 mV/div
±16 V @ 20 mV - 100 mV/div
±80 V @ 102 mV - 198 mV/div
±160 V @ 200 mV - 1 V/div
±400 V @ 1.02 V - 10 V/div
DC Vertical Offset Accuracy ±(0.5% of offset setting + 0.5% FS + 1mV)
Maximum Input Voltage 50 Ω: 5 Vrms,
1 MΩ: 400 V max
(DC + Peak AC ≤ 10 kHz)
Input Coupling 1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Input Impedance 50 Ω+/-2% or 1 MΩ||19pF, 10 MΩ || 10 pF
Bandwidth Limiters 20MHz, 200MHz, 350 MHz
Rescaling Length: meters, inches, feet, yards, miles; Mass: grams, slugs; Temperature: celsius, fahrenheit, kelvin; Angle: radian, arcdegr, arcmin, arcsec, cycles, revolutions, turns; Velocity: m/s, in/s, ft/s, yd/s, miles/s; Acceleration: m/s2, in/s2, ft/s2, g0; Volume: liters, cubic meters, cubic inches, cubic feet, cubic yards; Force (Weight): newton, grain, ounce, pound; Pressure: pascal, bar, atmosphere (technical), atmosphere (standard), torr, psi; Electrical: volts, amps, watts, volt-amperes, volt-amperes reactive, farad, coulomb, ohm, siemen, volt/meter, coulomb/m2, farad/meter, siemen/meter, power factor; Magnetic: weber, tesla, henry, amp/meter, henry/meter; Energy: joule, Btu, calorie; Rotating Machine: radian/second, frequency, revolution/second, revolution/minute, N?m, lb-ft, lb-in, oz-in, watt, horsepower; Other: %.
 

Horizontal - Analog Channels

Timebases Internal timebase common to 8 input channels
Acquisition Modes Real-time, Roll, Sequence
Time/Division Range 100 ps/div - 5 ks/div with standard memory (up to 10 ks/div with 500MPT memory, 25 ks/div with 1000MPT memory, 50 ks/div with 2000MPT memory, 100 ks/div with 5000MPT memory);
Roll Mode available at ≥ 100 ms/div and ≤ 5 MS/s
Clock Accuracy +/-1 ppm + 1 ppm/year from calibration
Sample Clock Jitter up to 10µs Acquired Time Range:
80 fsrms (Internal Timebase Reference)

up to 10ms Acquired Time Range:
150 fsrms (Internal Timebase Reference)
Delta Time Measurement Accuracy \sqrt{2}*\sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2) (RMS)+(clock accuracy*reading)(seconds)
Jitter Measurement Floor \sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2\; seconds\; rms\; (TIE)}
Channel-Channel Deskew Range ±9 x time/div. setting, 100 ms max., each channel
External Timebase Reference (Input) 10MHz +/-25ppm at 0 to 10dBm into 50 Ohms
External Timebase Reference (Output) 10MHz, 5.0 dBm +/-2.5 dBm, sinewave synchronized to reference being used (internal or external reference)
 

Acquisition - Analog Channels

Sample Rate (Single-shot) 10 GS/s on 8 Ch with Enhanced Sample Rate
Memory Length (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
50M/100M/200M
(65,536)
Memory Length Options (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
WR8KHD-500MPT Option:
125M / 250M / 500M (65,535)
WR8KHD-1000MPT Option:
250M / 500M / 1000M (65,535)
WR8KHD-2000MPT Option:
500M / 1000M / 2000M (65,535)
WR8KHD-5000MPT Option:
1250M / 2500M / 5000M (65,535)

Maximum analysis memory: 500 Mpts per channel
Intersegment Time 1.5 µs
Averaging Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
(Waveforms of ≤500Mpts)
Enhanced Resolution (ERES) From 12.5 to 15 bits vertical resolution
Envelope (Extrema) Envelope, floor, or roof for up to 1 million sweeps
(Waveforms of ≤500Mpts)
Interpolation Linear or Sin x/x (2 pt and 5 pt)
(Waveforms of ≤500Mpts)
 

Vertical, Horizontal, Acquisition - Digital Channels

Maximum Input Frequency 500 MHz
Minimum Detectable Pulse Width 1 ns
Input Channels 16 Digital channels (with WR8KHD-MSO option)
Input Impedance (Flying Leads) 100 kΩ || 5 pF
Input Dynamic Range ± 20V
Maximum Input Voltage ±30V Peak
Maximum Input Voltage Swing 400mV
Threshold Groupings Pod 2: D15 - D8, Pod 1: D7 - D0
Threshold Selections TTL, ECL, CMOS (2.5 V, 3.3 V, 5 V), PECL, LVDS or User Defined
Threshold Accuracy ±(3% of threshold setting + 100mV)
User Defined Threshold Range ±10 V in 20 mV steps
User Defined Hysteresis Range 100 mV to 1.4 V in 100 mV steps
Sample Rate 2.5GS/s
Record Length Standard: 50 Mpts
Any memory option: 500 Mpts
Channel-to-Channel Skew 350 ps
 

Triggering System

Modes Acquisition of ≤500Mpts:
Normal, Auto, Single, and Stop

Acquisition of >500Mpts:
Single
Sources Any input channel, Ext, Ext/10, or Line; slope and level unique to each source (except line trigger)
Coupling DC, AC, HFRej, LFRej
Pre-trigger Delay 0-100% of memory size
Post-trigger Delay No limitation
Hold-off From 2 ns up to 20 s or from 1 to 99,999,999 events
Trigger and Interpolator Jitter ≤ 2.5 psrms (typical)
<0.1 ps RMS (typical, software assisted)
Internal Trigger Level Range ±4.1 div from center (typical)
External Trigger Level Range Ext (±0.4 V); Ext/10 (±4 V)
Maximum Trigger Rate 650,000 waveforms/second (in Sequence Mode, up to 8 channels)
Trigger Sensitivity with Edge Trigger ProBus Inputs 1.5 div @ < 500 MHz
1 div @ < 200 MHz
0.9 div @ < 10 MHz
(DC, AC, and LFRej coupling, ≥ 2 mV/div, 50 Ω)
Trigger Sensitivity with Edge Trigger (Aux Input) 1.5 div @ < 500 MHz
1 div @ < 200 MHz
0.9 div @ < 10 MHz
(DC, AC, and LFRej coupling)
Max. Trigger Frequency, SMART Trigger 500 MHz
 

Trigger Types

Edge Triggers when signal meets slope (positive, negative, or either) and level condition.
Width Triggers on positive or negative glitches with selectable widths.
minimum width 750ps, Maximum Width: 20s
Glitch Triggers on positive or negative glitches with selectable widths. minimum width 750ps, Maximum Width: 20s
Window Triggers when signal exits a window defined by adjustable thresholds
Pattern Logic combination (AND, NAND, OR, NOR) of up to 9 inputs (8 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern.
Runt Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew Rate Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
Interval Triggers on intervals selectable between 1 ns and 20 s.
Dropout Triggers if signal drops out for longer than selected time between 1 ns and 20 s.
Measurement Trigger Select from a large number of measurement parameters. Trigger on a measurement value with qualified limits.
Multi-Stage: Qualified (Timeout or State/Edge Qualified) Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events. (Note: event B pattern trigger cannot include analog channels).
Triggers with Exclusion Technology Glitch, Width, Interval, Runt, Slew Rate - Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
Multi-Stage: Qualified First In Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events. (Note: event B pattern trigger cannot include analog channels).
TriggerScan A Trigger Trainer analyzes the waveforms, identifies normal behavior, and then sets up a large set of rare event smart trigger setups that target abnormal behavior. The trainer ‘learns’ trigger setups based on slew rates, periods, amplitudes outside of a range and then applies them sequentially.
 

Low Speed Serial Protocol Trigger (Optional)

Supported Protocols I2C, I3C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN1.1, CAN2.0, CAN FD, LIN, FlexRay, SENT, MIL-STD-1553, AudioBus
(I2S, LJ, RJ, TDM), USB1.x/2.0, SPMI
 

Measurement Tools

Measurement Functionality Display up to 12 measurement parameters together with statistics, including mean, minimum, maximum, standard deviation, and total number. Each occurrence of each parameter is measured and added to the statistics table. Histicons provide a fast, dynamic view of parameters and waveshape characteristics. Parameter math allows addition, subtraction, multiplication, or division of two different parameters. Parameter gates define the location for measurement on the source waveform. Parameter accept criteria define allowable values based on range setting or waveform state.
Measurement Parameters - Horizontal + Jitter Cycles (number of), Delay (from trigger, 50%), Δ Delay (50%), Duty Cycle (50%, @level), Edges (number of, @level), Fall Time (90-10, @levels), Frequency (50%, @level), Half Period (@level), Hold Time (@level), N Cycle Jitter (peak-peak), Number of Points, Period (50%, @level), Δ Period (@level), Phase (@level), Rise Time (10-90, @levels), Setup (@levels), Skew (@levels), Slew Rate (@levels), Time Interval Error (@level), Time (@level), Δ Time (@level), Width (50%, @level), Δ Width (@level), X(value)@max, X(value)@min
Measurement Parameters - Vertical Amplitude, Base, Level@X, Maximum, Mean, Median, Minimum, Peak-to-Peak, RMS, Std. Deviation, Top.
Measurement Parameters - Pulse Area, Base, Fall Time (90-10, 80-20, @levels), Overshoot (positive, negative), Rise Time (10-90, 80-20, @levels), Top, Width (50%)
Measurement Parameters - Statistical (on Histograms) Full Width (@ Half Max, @ %), Amplitude, Base, Peak @ Max Population, Maximum, Mean, Median, Minimum, Mode, Range, RMS, Std. Deviation, Top, X(value)@Peak, Peaks (number of), Percentile, Population (@bin, total)
 

Math Tools

Math Functionality Display up to 12 math functions traces (F1-F12). The easy-to-use graphical interface simplifies setup of up to two operations on each function trace, and function traces can be chained together to perform math-on-math.
Math Operators - Basic Math Average (summed), Average (continuous), Difference (-), Envelope, Floor, Invert (negate), Product (x), Ratio (/), Reciprocal, Rescale (with units), Roof, Sum (+).
Math Operators - Digital (incl. with MSO models/options) Digital AND, Digital DFlipFlop, Digital NAND, Digital NOR, Digital NOT, Digital OR, Digital XOR
Math Operators - Filters Enhanced resolution (to 15 bits vertical), Interpolate (cubic, quadratic, sinx/x), (SinX)/x.
Math Operators - Frequency Analysis FFT (power spectrum, magnitude, phase, power density, real, imaginary, magnitude squared), up to full record length. Select from Rectangular, VonHann, Hamming, FlatTop and Blackman Harris windows.
Math Operators - Functions Absolute value, Correlation (two waveforms), Derivative, Deskew (resample), Exp (base e), Exp (base 10), Integral, Invert (negate), Log (base e), Log (base 10), Reciprocal, Rescale (with units), Square, Square root, Zoom (identity).
Math Operators - Other Segment, Sparse
 

Measurement and Math Integration

Measurement and Math Integration Histograms to display statistical distributions of up to 2 billion measurement parameters. Trend (datalog) of up to 1 million measurement parameters. Track (display parameter vs. time, time-correlated to acquisitions) any parameter. Persistence histogram and persistence trace (mean, range, sigma)
 

Pass/Fail Testing

Pass/Fail Testing Display up to 12 pass/fail queries using a Single or Dual Parameter Comparison (compare All values, or Any value <. ≤, =, >, ≥, within limit ±Δ value or %) or Mask Test (pre-defined or user-defined mask, waveform All In, All Out, Any In, or Any Out conditions). Combine queries into a boolean expression to Pass or Fail IF "All True", "All False", "Any True", "Any False", or groups or "All" or "Any", with following THEN Save (waveforms), Stop, Alarm, (send) Pulse, Hardcopy (send email, save screen image, save to clipboard, send to printer), or (save) LabNotebook.
 

Display System

Size Color 15.6" widescreen capacitive touch screen
Resolution 1920 x 1080 pixels
Number of traces Display a maximum of 40 traces. Simultaneously display channel, zoom, memory, and math.
Grid Styles Auto, Single, Dual, Triplex, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y, Tandem, Triad, Quattro, Twelve, Sixteen, Twenty.
Supports Normal Display Mode (1 grid style, selectable) or Q-Scape Display Mode (4 different tabs, each with individually selectable grid styles). Q-Scape tabbed displays may be viewed in Single, Dual, or Mosaic mode.
Waveform Representation Sample dots joined, or sample dots only
 

Persistence Display

Analog and Color-Graded Persistence Waveforms of ≤500Mpts:
Variable saturation levels; stores each trace’s persistence data in memory
Persistence Types Waveforms of ≤500Mpts:
Select analog, color, or three-dimensional
Trace Selection Waveforms of ≤500Mpts:
Activate persistence on all or any combination of traces
Persistence Aging Waveforms of ≤500Mpts:
Select from 500 ms to infinity
Sweep Display Modes Waveforms of ≤500Mpts:
All accumulated, or all accumulated with last trace highlighted
 

Zoom Expansion Traces

Zoom Expansion Traces Display up to 12 Zoom and 12 Math/Zoom traces
 

Internal Waveform Memory

Internal Waveform Memory 12 active waveform memory traces (M1-M12) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.
 

Setup Storage

Front Panel and Instrument Status Store to the internal hard drive, over the network, or to a USB-connected peripheral device.
 

Automatic Setup

Auto Setup Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical Scale Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range
 

Calibration

Calibration Stability Calibration ensured within +/-5°C operating temperature. Manual calibration may be invoked if outside this temperature range.
 

Processor/CPU

Type Intel® Core i5-6500 Quad Core, 3.2 GHz (or better)
Processor Memory 16 GB standard for standard memory with 32 GB optional.
32 GB standard for any memory option.
Operating System Microsoft Windows® 10
Oscilloscope Operating Software Teledyne LeCroy MAUI™ with OneTouch
Real Time Clock Date and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks.
 

Connectivity

Ethernet Port 2 x 10/100/1000BaseT Ethernet interface (RJ45 port)
USB Host Ports 4 side USB 3.1 Gen1 ports, 2 front USB 3.1 Gen1 ports
USB Device Port 1 port - USBTMC over USB 3.1 Gen1
GPIB Port (optional) Supports IEEE - 488.2 (External)
External Monitor Port 1 x DisplayPort, supports up to 4096x2304 @ 24 Hz
1 x HDMI, supports up to 4096x2304 @ 60 Hz
Remote Control Via Windows Automation, or via LeCroy Remote Command Set
Network Communication Standard VXI-11 or VICP, LXI Compatible
 

Auxiliary Input

Signal Types For external trigger input
Coupling 50 Ω: DC; 1 MΩ: AC, DC, GND
Max. Input Voltage 50 Ω
5V RMS, +/- 10V Peak

1 MΩ
400 V max (Peak DC+AC)
 

Auxiliary Output

Signal Types Select from output signal, control signals, off
Output Signal 500 Hz-5 MHz square wave or DC level; 3.3 V +/- 10% into 1 MΩ
Control Signals Trigger enabled, trigger out, pass/fail status, off
Connector Type BNC, located on rear panel
 

Probes

Probes Qty. (4) ÷10 Passive Probes
Probe System ProBus. Automatically detects and supports a variety of compatible probes
Scale Factors Automatically or manually selected depending on probe used
Calibration Output Default is 1kHz square wave, 1Vp-p (typical), output to probe hook. Settable from 500 Hz to 1 MHz square wave; 50 mV to 1.0V.
 

Power Requirements

Voltage 100 - 240 VAC ±10% at 47 - 63 Hz
100 - 120 VAC ±10% at 380 - 420 Hz
Automatic AC Voltage Selection
Nominal Power Consumption 400 W / 400 VA
Max. Power Consumption 500 W / 500 VA (with all PC peripherals and active probes connected to 8 channels)
 

Environmental

Temperature (Operating) +5 °C to +40 °C
Temperature (Non-Operating) -20 °C to +60 °C
Humidity (Operating) 5% to 90% relative humidity (non-condensing) up to +31 °C.
Upper limit derates to 50% relative humidity (non-condensing) at +40 °C.
Humidity (Non-Operating) 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating) Up to 10,000 ft. (3048 m) at or below +30 °C
Altitude (Non-Operating) Up to 40,000 ft. (12,192 m)
Random Vibration (Operating) 0.31 grms 5 Hz to 500 Hz, 20 minutes in each of three orthogonal axes
Random Vibration (Non-Operating) 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Functional Shock 30 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
 

Size and Weight

Dimensions (HWD) 13.6”H x 17.5”W x 7.7”D (345 mm x 445 mm x 196 mm)
Weight 24.4 lbs (11.1 kg)
Shipping Weight 37 lbs (16.8 kg)
 

Certifications

CE Certification
UL and cUL Listing
CE Compliant, UL and cUL listed; conforms to
UL 61010-1 (3rd Edition), UL 61010-2-030 (1st Edition)
CAN/CSA C22.2 No. 61010-1-12
 

Warranty and Service

Warranty and Service 3-year warranty; calibration recommended annually.
Optional service programs include extended warranty, upgrades, and calibration services.
 

Mixed Signal Option

WR8KHD-MSO
Mixed Signal Option for WaveRunner/MDA 8000HD (includes probe, accessories, and license)

Memory Options

WR8KHD-500MPT
500 Mpt/2Ch (250 Mpt/4Ch, 125 Mpt/8Ch) Memory Option for WaveRunner/MDA 8000HD (includes 32GB RAM)
WR8KHD-1000MPT
1 Gpt/2Ch (500 Mpt/4Ch, 250 Mpt/8Ch) Memory Option for WaveRunner/MDA 8000HD (includes 32GB RAM)
WR8KHD-2000MPT
2 Gpt/2Ch (1 Gpt/4Ch, 500 Mpt/8Ch) Memory Option for WaveRunner/MDA 8000HD (includes 32GB RAM)
WR8KHD-5000MPT
5 Gpt/2Ch (2.5 Gpt/4Ch, 1.25 Gpt/8Ch) Memory Option for WaveRunner/MDA 8000HD (includes 32GB RAM)

Synchronize Oscilloscope Options

WR8KHD-16CH-SYNCH
16 channel OscilloSYNC software option (combine 2 WaveRunner/MDA 8000HD Oscilloscopes)

Computer Upgrade

WR8KHD-RSSD-02
Additional Standard Solid State Drive for WaveRunner/MDA 8000HD
WR8KHD-UPG-32GBRAM
16GB to 32GB CPU RAM upgrade option for WaveRunner/MDA 8000HD

Remote Control/Network Options

USB2-GPIB
External USB 2.0 to GPIB IEEE 488.2 adapter

Power Analysis Software

WR8KHD-POWER-DEVICE
Power Device Analysis Option for WaveRunner/MDA 8000HD
WR8KHD-THREEPHASEVECTOR
3-phase Vector Display option for WaveRunner and MDA 8000HD
WR8KHD-THREEPHASEDQ0
3-phase dq0 Transform option for WaveRunner and MDA 8000HD
WR8KHD-PWR
Power Analysis Option for WaveRunner/MDA 8000HD
WR8KHD-DIG-PWR-MGMT
Digital Power Management Analysis Option for WaveRunner/MDA 8000HD
WR8KHD-THREEPHASEPOWER
3-phase Power Analysis Software Option for WaveRunner 8000HD
WR8KHD-THREEPHASEHARMONICS
3-phase Harmonics Calculation Option for WaveRunner/MDA 8000HD

Serial Trigger and Decode

WR8KHD-1000BASE-T1 TDMP
1000Base-T1 Trigger, Decode, Measure/Graph, and Physical Layer Opt. for WaveRunner/MDA 8000HD
WR8KHD-100BASE-T1 TDMP
100Base-T1 Trigger, Decode, Measure/Graph, and Physical Layer Opt. for WaveRunner/MDA 8000HD
WR8KHD-100Base-T1bus TD
100Base-T1 Trigger and Decode Option for WaveRunner/MDA 8000HD
WR8KHD-USBPD TDMP
USB-PD Trigger, Decode, Measure/Graph, and Physical Layer Option for WaveRunner/MDA 8000HD
WR8KHD-DPAUX DMP
DisplayPort AUX Decode, Measure/Graph, and Physical Layer Option for WaveRunner/MDA 8000HD
WR8KHD-10BASE-T1S TDME
10Base-T1S Trigger, Decode, Measure/Graph, and Eye Diagram Option for WaveRunner/MDA 8000HD
WR8KHD-USB4SB TDMP
USB4-SB Trigger, Decode, Measure/Graph, and PHY Measurement Option for WaveRunner/MDA 8000HD
WR8KHD-1553 TD
MIL-STD-1553 Trigger and Decode Option for WaveRunner/MDA 8000HD
WR8KHD-10BASE-T1S TD
10Base-T1S Trigger and Decode Option for WaveRunner/MDA 8000HD
WR8KHD-USB4SB TD
USB4-SB Trigger and Decode Option for WaveRunner/MDA 8000HD
WR8KHD-1553 TDME
MIL-STD-1553 Trigger, Decode, Measure/Graph, and Eye Diagram Option for WaveRunner/MDA 8000HD
WR8KHD-8B10B D
8b10b Decode Option for WaveRunner/MDA 8000HD
WR8KHD-DPAUX D
DisplayPort AUX Decode Option for WaveRunner/MDA 8000HD
WR8KHD-ARINC429BUS D SYMBOLIC
ARINC 429 Bus Symbolic Decode Option for WaveRunner/MDA 8000HD
WR8KHD-ARINC429BUS DME SYMBOLIC
ARINC 429 Bus Symbolic Decode, Measure/Graph, and Eye Diagram Option for WaveRunner/MDA 8000HD
WR8KHD-AUDIOBUS TD
AudioBus Trigger and Decode Option for WaveRunner/MDA 8000HD
WR8KHD-AUDIOBUS TDG
AudioBus Trigger, Decode, and Graph Option for WaveRunner/MDA 8000HD
WR8KHD-CAN FDBUS TD
CAN and CAN FD Trigger and Decode Option for WaveRunner/MDA 8000HD
WR8KHD-CAN FDBUS TDME SYMBOLIC
CAN/CAN FD Symbolic Trigger, Decode, Measure/Graph, and Eye Diagram Option for WaveRunner/MDA 8000HD
WR8KHD-CAN XL TD
CAN/ CAN FD/ CAN XL Trigger and Decode Option for WaveRunner/MDA 8000HD
WR8KHD-CAN XL TDME SYMBOLIC
CAN /CAN FD/ CAN XL Symbolic Trigger, Decode, Measure/Graph, and Eye Diagram Opt. for WR/MDA 8000HD
WR8KHD-DIGRF3GBUS D
DigRF 3G Bus Decode Option for WaveRunner/MDA 8000HD
WR8KHD-DIGRFV4BUS D
DigRF V4 Bus Decode Option for WaveRunner/MDA 8000HD
WR8KHD-EMB TD
Bundle: Includes I2C, SPI, UART-RS232 Trigger and Decode Options for WaveRunner/MDA 8000HD
WR8KHD-EMB TDME
Bundle: Incl. I2C, SPI, UART-RS232 Trig, Decode, Measure/Graph, and Eye Diagram Opt for WR/MDA 8KHD
WR8KHD-ENETBUS D
ENET Bus Decode Option for WaveRunner/MDA 8000HD
WR8KHD-FLEXRAYBUS TD
FlexRay Trigger and Decode Option for WaveRunner/MDA 8000HD
WR8KHD-FLEXRAYBUS TDMP
FlexRay Trigger, Decode, Measure/Graph and Physical Layer Option for WaveRunner/MDA 8000HD
WR8KHD-I2CBUS TD
I2C Trigger and Decode Option for WaveRunner/MDA 8000HD
WR8KHD-I2CBUS TDME
I2C Trigger, Decode, Measure/Graph, and Eye Diagram Option for WaveRunner/MDA 8000HD
WR8KHD-I3CBUS TD
I3C Trigger and Decode Option for WaveRunner/MDA 8000HD (I2C supported)
WR8KHD-I3CBUS TDME
I3C Trigger, Decode, Measure/Graph, and Eye Diagram Option for WaveRunner/MDA 8000HD (I2C supported)
WR8KHD-LINBUS TD
LIN Trigger and Decode Option for for WaveRunner/MDA 8000HD
WR8KHD-LINBUS TDME
LIN Trigger, Decode, Measure/Graph, and Eye Diagram Option for for WaveRunner/MDA 8000HD
WR8KHD-MANCHESTERBUS D
Manchester Bus Decode Option for WaveRunner/MDA 8000HD
WR8KHD-MDIOBUS D
MDIO Decode for WaveRunner/MDA 8000HD
WR8KHD-NRZBUS D
NRZ Bus Decode Option for WaveRunner/MDA 8000HD
WR8KHD-PMBus TD
PMBus Trigger and Decode Option for WaveRunner/MDA 8000HD
WR8KHD-PMBus TDME
PMBus Trigger, Decode, Measure/Graph, and Eye Diagram Option for WaveRunner/MDA 8000HD
WR8KHD-SENTbus TD
SENT Trigger and Decode Option for WaveRunner/MDA 8000HD
WR8KHD-SENTbus TDME
SENT Trigger, Decode, Measure/Graph, and Eye Diagram Option for WaveRunner/MDA 8000HD
WR8KHD-SMBus TD
SMBus Trigger and Decode Option for WaveRunner/MDA 8000HD
WR8KHD-SMBus TDME
SMBus Trigger, Decode, Measure/Graph, and Eye Diagram Option for WaveRunner/MDA 8000HD
WR8KHD-SPACEWIREBUS D
SpaceWire Decode Option for WaveRunner/MDA 8000HD
WR8KHD-SPIBUS TD
SPI Trigger and Decode Option for WaveRunner/MDA 8000HD
WR8KHD-SPIBUS TDME
SPI Trigger, Decode, Measure/Graph, and Eye Diagram Option for WaveRunner/MDA 8000HD
WR8KHD-SPMIBUS TD
SPMI Trigger and Decode Option for WaveRunner/MDA 8000HD
WR8KHD-SPMIBUS TDME
SPMI Trigger, Decode, Measure/Graph, and Eye Diagram Option for WaveRunner/MDA 8000HD
WR8KHD-UART-RS232BUS TD
UART-RS232 Trigger and Decode Option for WaveRunner/MDA 8000HD
WR8KHD-UART-RS232BUS TDME
UART-RS232 Trigger, Decode, Measure/Graph, and Eye Diagram Option for WaveRunner/MDA 8000HD
WR8KHD-USB2BUS TD
USB 2.0 Decode Option for WaveRunner/MDA 8000HD
WR8KHD-USB2BUS TDME
USB 2.0 Decode, Measure/Graph, and Eye Diagram Option for WaveRunner/MDA 8000HD
WR8KHD-USB2-HSICBUS D
USB 2.0 HSIC Decode Option for WaveRunner/MDA 8000HD
WR8KHD-USBPD TD
USB-PD Trigger and Decode Option for WaveRunner/MDA 8000HD

Jitter Analysis Software

WR8KHD-JITKIT
Clock, clock-data Jitter Analysis and views of time, statistical, spectral, and jitter overlay

Digital Filtering Software

WR8KHD-DFP2
Digital Filter Software Package for WaveRunner/MDA 8000HD

Serial Data Compliance

QPHY-NBASE-T
QualiPHY Enabled NBASE-T (2.5GBase-T & 5GBASE-T) Compliance Software Option
WR8KHD-AUTO-ENET-TOOLKIT
100Base-T1 and 1000Base-T1 Debug Toolkit for WaveRunner/MDA 8000HD
QPHY-100Base-T1
QualiPHY Enabled 100Base-T1 (Automotive Ethernet) Compliance Software Option
QPHY-10Base-T1L
QualiPHY Enabled 10Base-T1L (Industrial Ethernet) Compliance Software Option
QPHY-10Base-T1S
QualiPHY Enabled 10Base-T1S (Automotive Ethernet) Compliance Software Option
QPHY-MOST50
QualiPHY Enabled MOST50 ePHY Compliance Software Option. Requires options DFP2 and SDM or SDA3
QPHY-USB
QualiPHY Enabled USB 2.0 Compliance Software Option

Serial Data Analysis

WR8KHD-SDAX-NRZ
NRZ Serial Data Expert Analysis Framework, Eye, Jitter and Noise Measurements
WR8KHD-SDAX-PAM
PAM Serial Data Expert Analysis Framework, Eye,Jitter and Noise Measurements
WR8KHD-SDAIII
Single-Lane Serial Data Analysis, Eye and Jitter Measurements for WaveRunner/MDA 8000HD
WR8KHD-EYEDRII
Signal Integrity Toolkit - Channel & Fixture De-embedding/Emulation, Tx/Rx Equalization
WR8KHD-VIRTUALPROBE
Advanced De-embedding, Emulation and Virtual Probing Toolkit
WR8KHD-SDM
Serial Data Mask Software Package for WaveRunner/MDA 8000HD
WR8KHD-CBL-DE-EMBED
Cable De-Embedding Option for WaveRunner/MDA 8000HD

Other Software Options

MAUI Studio Pro
MAUI Studio Pro Offline Remote and PC Analysis Software License
WR8KHD-EMC
EMC Pulse Parameter Software Package for WaveRunner/MDA 8000HD
WR8KHD-SPECTRUM-1
Spectrum Analyzer for WaveRunner 8000HD - 1 trace
WR8KHD-SPECTRUM-PRO-2R
Spectrum Analyzer for WaveRunner 8000HD - 2 traces + reference
WR8KHD-VECTORLINQ
VectorLinQ Vector Signal Analysis for WaveRunner/MDA 8000HD
WR8KHD-XDEV
Advanced Customization Option for WaveRunner/MDA 8000HD

Miscellaneous

OC1024-A
Instrument Cart with additional shelf and drawer
WR8KHD-RACKMOUNT
Rackmount kit for WaveRunner/MDA 8000HD

Serial Data Test Fixtures

TF-AUTO-ENET-SMA
4 pack of SMA Connector boards for TF-AUTO-ENET
TF-AUTO-HMTD
Test Fixture HMTD-Connector (m) to SMA (f)
TF-AUTO-MATENET
Test Fixture MATEnet-Connector (m) to SMA (f)
TF-AUTO-MINI50
Test Fixture Mini-50-Connector (m) to SMA (f)
TF-NBASE-T
TF-NBASE-T supports both NBase-T and 10GBase-T compliance testing. It breaks out the A, B, C and D pairs from the Ethernet cable to SMA connectors. The kit includes power splitter (2) for adding the disturbing signal (for 2.5GBase-T), 50 Ohm terminators (6), Ethernet cables (2), SMA/SMA cables (2) and SMA/BNC cables (4) needed for testing.
TF-USB-C-SB
USB4 Sideband Test Coupon Fixture

Active Voltage Probes

ZS1500
1.5 GHz, 0.9 pF, 1 MOhm Active Voltage Probe
ZS1000
1 GHz, 0.9 pF, 1 MOhm Active Voltage Probe

Differential Probes (<= 1.5 GHz)

AP033
500 MHz Differential Probe
ZD200
200 MHz, 3.5 pF, 1 MOhm Active Differential Probe, ±20 V Limited Availability
ZD500
500 MHz, 1.0 pF Active Differential Probe, ±8 V
ZD1000
1 GHz, 1.0 pF Active Differential Probe, ±8 V
ZD1500
1.5 GHz, 1.0 pF Active Differential Probe, ±8 V

Current Probes

CP150
150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 2 meter cable Limited Availability
CP500
500 A, 2 MHz Current Probe - AC/DC, 500 A rms, 700 A Peak Pulse, 6 meter cable
CP030
30A, 50 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable Limited Availability
CP031
30A, 100 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP030A
30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable Limited Availability
CP031A
30A, 100 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CA10
Programmable Current Sensor to ProBus Adapter for use with third party current sensors
CP030-3M
30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 3 meter cable
CP150-6M
150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 meter cable
DCS025
Deskew Calibration Source for Teledyne LeCroy current probes
CP150B
150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 2 meter cable
CP030B
30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable

High Voltage Passive Probes

HVP120
6kV High Voltage Passive Probe, 400 MHz
PPE6KV-A
6kV High Voltage Passive Probe, 500 MHz

Passive Probes

PP021-1
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP025-1
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm

High Voltage Differential Probes

AP031
700 V, 25 MHz High-Voltage Differential Probe (÷10, ÷100) Limited Availability
HVD3102A
1kV, 25 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3102A-NOACC
1kV, 25 MHz High Voltage Differential Probe without tip Accessories and with Auto Zero Disconnect
HVD3106A
1kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3106A-NOACC
1kV, 120 MHz High Voltage Differential Probe without tip Accessories and with Auto Zero Disconnect
HVD3106A-6M
1kV, 80 MHz High Voltage Differential Probe with 6m cable and Auto Zero Disconnect
HVD3206A
2kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3206A-6M
2kV, 80 MHz High Voltage Differential Probe with 6m cable and Auto Zero Disconnect
HVD3605A
6kV, 100 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3220
2kV, 400 MHz High Voltage Differential Probe

Transmission Line Probes

PP066
7.5 GHz low capacitance Passive Probe, 500/1K Ohms

Probe Parts and Kits

PACC-ZD001
Y lead Adapter for ZD differential probes - Qty 1
PACC-ZD002
Solder-in lead for ZD differential probe - QTY 2
PACC-ZD003
Long spring ground for ZD differential probe - QTY 2
PACC-ZD004
Tip saver for ZD differential probe - QTY 2
PACC-ZD005
Swivel tip adapter for ZD differential probe - QTY 1
PACC-ZD006
Small IC adapter for ZD differential probe - QTY 2
PK111
Replacement Accessory kit for ZD500, ZD1000, and ZD1500

Probe Adapters

TPA10
TekProbe to ProBus Probe Adapter

Active Voltage Rail Probe

RP4030
Power/Voltage Rail Probe. 4 GHz bandwidth, 1.2x attenuation, +/-30V offset, +/-800mV Includes a complete set of solder-in leads, coaxial cables, and PCB mounts. Limited Availability
RP4000-MCX-LEAD-SI
Qty 3 MCX 4 GHz solder-in lead accessories (additional to those supplied with rail probe) 18cm long
RP4000-BROWSER
RP2060/RP4060 Browser Tip accessory. Includes 0 Ohm (1x), 450 Ohm (10x) and 950 Ohm (20x) tips.
RP4060
Power/Voltage Rail Probe. 4 GHz bandwidth, 1.2x attenuation, +/-60V offset, +/-800mV Includes a complete set of solder-in leads and coaxial cables. Browser tip sold seperately
RP2060
Power/Voltage Rail Probe. 2 GHz bandwidth, 1.2x attenuation, +/-60V offset, +/-800mV Includes a complete set of solder-in leads and coaxial cables. Browser tip sold seperately

High Voltage Optically Isolated Probes

HVFO100-1X-TIP-U
HVFO10X +/-1V (1x Attenuation) Universal Tip Accessory
HVFO100-5X-TIP-U
HVFO10X +/-5V (5x Attenuation) Universal Tip Accessory
HVFO100-10X-TIP-U
HVFO10X +/-10V (10x Attenuation) Universal Tip Accessory
HVFO100-20X-TIP-U
HVFO10X +/-20V (20x Attenuation) Universal Tip Accessory
HVFO100-40X-TIP-U
HVFO10X +/-40V (40x Attenuation) Universal Tip Accessory
HVFO108
High Voltage Fiber Optic Probe, 150 MHz Bandwidth. Includes soft-carrying case. Requires attenuating tip (ordered separately). Includes Qty. 1 1m Fiber Optic Cable.
DL10-ISO
High Voltage Optically Isolated Probe, 1 GHz Bandwidth. Includes soft-carrying case.
DL07-ISO
High Voltage Optically Isolated Probe, 700 MHz Bandwidth. Includes soft-carrying case.
DL03-ISO
High Voltage Optically Isolated Probe, 350 MHz Bandwidth. Includes soft-carrying case.
DL-ISO-2V-TIP
DL-ISO 2 Vpp MMCX Tip
DL-ISO-10V-TIP
DL-ISO 10 Vpp MMCX Tip
DL-ISO-40V-TIP
DL-ISO 40 Vpp MMCX Tip
DL-ISO-200V-TIP
DL-ISO 200 Vpp MMCX Tip
DL-ISO-1000V-TIP
DL-ISO 1000 Vpp Square Pin Tip
DL-ISO-2500V-TIP
DL-ISO 2500 Vpp Square Pin Tip
DL-ISO-ACC-KIT
DL-ISO series accessories kit Incl MMCX to Y-lead sockets/solder-ins, square pin socket/solder-ins, MMCX-sq pin adapter, grabbers

60 V Common Mode Differential Probes

DL05-HCM
500 MHz 60 V Common Mode Differential Probe. Includes standard set of leads and tips.
DL10-HCM
1 GHz 60 V Common Mode Differential Probe. Includes standard set of leads and tips.
DL-HCM-HiTemp
DL-HCM series high-temperature solder-in tip, 30 MHz bandwidth, 1 meter length.
DL-HCM-Acc-Kit
DL-HCM series accessories kit with probe holder, micro IC grabbers (Qty 2.), and Y-banana adaptor.
DL02-HCM
250 MHz 60 V Common Mode Differential Probe. Includes standard set of leads and tips.