Products
Oscilloscopes

HDO6034A

350 MHz,4 Ch, 12-bit,10 GS/s, 50 Mpts/Ch High Definition Oscilloscope with 12.1" WXGA Color Display


HDO6034A   (350 MHz Bandwidth, 4 Input Channels, 10 GS/s)
Quick Specs
Bandwidth350 MHz
Sample Rate10 GS/s on 4 Ch with ESR
Maximum Acquisition Memory250 Mpts (4 Ch operation)
Input Channels4
Vertical Resolution12-bits
HDO6054A   (500 MHz Bandwidth, 4 Input Channels, 10 GS/s)
Quick Specs
Bandwidth500 MHz
Sample Rate10 GS/s on 4 Ch with ESR
Maximum Acquisition Memory250 Mpts (4 Ch operation)
Input Channels4
Vertical Resolution12-bits
HDO6104A   (1 GHz Bandwidth, 4 Input Channels, 10 GS/s)
Quick Specs
Bandwidth1 GHz
Sample Rate10 GS/s on 4 Ch with ESR
Maximum Acquisition Memory250 Mpts (4 Ch operation)
Input Channels4
Vertical Resolution12-bits
HDO6034A-MS   (350 MHz Bandwidth, 4+16 Input Channels, 10 GS/s)
Quick Specs
Bandwidth350 MHz
Sample Rate10 GS/s on 4 Ch with ESR
Maximum Acquisition Memory250 Mpts (4 Ch operation)
Input Channels4
Vertical Resolution12-bits
HDO6054A-MS   (500 MHz Bandwidth, 4+16 Input Channels, 10 GS/s)
Quick Specs
Bandwidth500 MHz
Sample Rate10 GS/s on 4 Ch with ESR
Maximum Acquisition Memory250 Mpts (4 Ch operation)
Input Channels4
Vertical Resolution12-bits
HDO6104A-MS   (1 GHz Bandwidth, 4+16 Input Channels, 10 GS/s)
Quick Specs
Bandwidth1 GHz
Sample Rate10 GS/s on 4 Ch with ESR
Maximum Acquisition Memory250 Mpts (4 Ch operation)
Input Channels4
Vertical Resolution12-bits
Check up to three models.
Key Features
  • 4 input channels
  • 16 digital channels (with –MS models)
  • 12-bit ADC resolution, up to 15 bits with enhanced resolution
  • Up to 10 GS/s with Enhanced Sample Rate
  • 350 MHz, 500 MHz, and 1 GHz bandwidths
  • ±10 V applied offset with high gain settings
  • Long Memory - up to 250 Mpts/Ch
  • MAUI with OneTouch user interface
  • Exceptional Serial Data Tools
  • Powerful, Deep Toolbox

 

HD4096 High Definition Technology

Enables capture and display of signals with 16 times more resolution than other oscilloscopes. Waveforms captured and displayed are cleaner and crisper. Signal details often lost in the noise on other oscilloscopes are clearly visible and easy to distinguish with HD4096. HD4096 enables oscilloscopes to deliver unmatched measurement precision for improved debug and analysis.

Huge Applied Offset Range

A 16-bit offset DAC permits ±10 V offset at 20 mV/div, ±4 V at 5 mV/div, and an amazing ±1.6 V offset at the highest sensitivity (1 mV/div). Such large applied offsets (combined with 12 bits) make it easy to acquire and view small signal variations (e.g. ripple, noise, transient interference) on DC or sensor signals. They also provide extended offset ranges for many of Teledyne LeCroy’s high voltage probes

.
MAUI with OneTouch

MAUI – Most Advanced User Interface puts all the power and capabilities of the oscilloscope right at your fingertips. Designed for touch, built for simplicity, and made to solve. MAUI with OneTouch incorporates drag, drop and flick to provide unsurpassed efficiency in oscilloscope operation. Learn more about MAUI

Exceptional Serial Data Tools

Up to 23 standards supported – all with the industry’s best serial decoder. Many are provided with high performance triggers, unique measure and graph tools for validation efficiency (including a software serial DAC), and eye diagrams and physical layer testing tools. Learn more at teledynelecroy.com/tdme

Powerful, Deep Toolbox

Our waveshape analysis tools and application packages provide unparalleled insight. Learn more at Periodic Table of Oscilloscope Tools. Combine our powerful, deep toolbox with up to 250 Mpts/ch of acquisition memory and the most powerful motherboard in its class – an Intel® Core™ i7-2710QE Quad (core), 3.0 GHz (per core, in turbo mode), with 16 GB of RAM standard.

Vertical - Analog Channels

Analog Bandwidth (Max) 350 MHz
Analog Bandwidth @ 50 Ω (-3 dB) (ProBus Input) 350 MHz
(≥1 mV/div)
Analog Bandwidth @ 1 MΩ (-3 dB) (ProBus Input) 350 MHz (typical)
Rise Time (10-90%, 50 Ω) 1 ns (typical)
Rise Time (20-80%, 50 Ω) 750 ps (typical)
Input Channels 4
Vertical Resolution 12 bits; up to 15 bits with enhanced resolution (ERES)
Effective Number of Bits (ENOB) 8.7 bits
Vertical Noise Floor (1 mV/div) 85 uVrms
Vertical Noise Floor (2 mV/div) 85 uVrms
Vertical Noise Floor (5 mV/div) 90 uVrms
Vertical Noise Floor (10 mV/div) 95 uVrms
Vertical Noise Floor (20 mV/div) 110 uVrms
Vertical Noise Floor (50 mV/div) 210 uVrms
Vertical Noise Floor (100 mV/div) 360 uVrms
Vertical Noise Floor (200 mV/div) 1.10 mVrms
Vertical Noise Floor (500 mV/div) 2.10 mVrms
Vertical Noise Floor (1 V/div) 3.70 mVrms
Sensitivity 50 Ω: 1 mV-1 V/div, fully variable;
1 MΩ: 1 mV-10 V/div, fully variable
DC Vertical Gain Accuracy (Gain Component of DC Accuracy) ±(0.5%) F.S, offset at 0 V
Channel-Channel Isolation DC-200 MHz: 60 dB (>1000:1),
200 MHz up to rated BW: 50 dB (>300:1),
(For any two input channels, same v/div settings, typical)
Offset Range 50 Ω
±1.6 V @ 1 mV - 4.95 mV/div
±4 V @ 5 mV - 9.9 mV/div
±8 V @ 10 mV - 19.8 mV/div
±10 V @ 20 mV - 1 V/div

1 MΩ
±1.6 V @ 1 mV - 4.95 mV/div
±4 V @ 5 mV - 9.9 mV/div
±8 V @ 10 mV - 19.8 mV/div
±16 V @ 20 mV - 100 mV/div
±80 V @ 102 mV - 198 mV/div
±160 V @ 200 mV - 1 V/div
±400 V @ 1.02 V - 10 V/div
DC Vertical Offset Accuracy ±(1.0% of offset setting + 0.5%FS + 0.02% of max offset + 1mV)
Maximum Input Voltage 50 Ω: 5 Vrms,
1 MΩ: 400 V max
(DC + Peak AC ≤ 10 kHz)
Input Coupling 1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Input Impedance 1 MΩ ± 2.0% || 15 pF,
50 Ω ± 2.0%
Bandwidth Limiters 20MHz, 200MHz
Rescaling Length: meters, inches, feet, yards, miles; Mass: grams, slugs; Temperature: celsius, fahrenheit, kelvin; Angle: radian, arcdegr, arcmin, arcsec, cycles, revolutions, turns; Velocity: m/s, in/s, ft/s, yd/s, miles/s; Acceleration: m/s2, in/s2, ft/s2, g0; Volume: liters, cubic meters, cubic inches, cubic feet, cubic yards; Force (Weight): newton, grain, ounce, pound; Pressure: pascal, bar, atmosphere (technical), atmosphere (standard), torr, psi; Electrical: volts, amps, watts, volt-amperes, volt-amperes reactive, farad, coulomb, ohm, siemen, volt/meter, coulomb/m2, farad/meter, siemen/meter, power factor; Magnetic: weber, tesla, henry, amp/meter, henry/meter; Energy: joule, Btu, calorie; Rotating Machine: radian/second, frequency, revolution/second, revolution/minute, N·m, lb-ft, lb-in, oz-in, watt, horsepower; Other: %.
 

Horizontal - Analog Channels

Timebases Internal timebase common to 4 input channels; an external clock may be applied at the auxiliary input
Acquisition Modes Real-time, Roll, Random Interleaved Sampling (RIS), Sequence
Time/Division Range 20 ps/div - 5 ks/div with standard memory (up to 10 ks/div with -L memory, 25 ks/div with -XL memory);
RIS available at ≤ 10 ns/div; Roll Mode available at ≥ 100 ms/div and ≤ 5 MS/s
Clock Accuracy +/-2.5ppm + 1.0ppm/year from calibration
Sample Clock Jitter up to 10ms Acquired Time Range:
280fsrms (Internal Timebase Reference)
Delta Time Measurement Accuracy \sqrt{2}*\sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2) (RMS)+(clock accuracy*reading)(seconds)
Jitter Measurement Floor \sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2\; seconds\; rms\; (TIE)}
Jitter Between Channels 2psrms (TIE, typical)
Channel-Channel Deskew Range ±9 x time/div. setting, 100 ms max., each channel
External Timebase Reference (Input) 10MHz +/-25ppm at 0 to 10dBm into 50 Ohms
External Timebase Reference (Output) 10MHz, 2.0 dBm +/-1.5 dBm, sinewave synchronized to reference being used (internal or external reference)
External Clock DC to 100 MHz; (50 Ω/1 MΩ), EXT BNC input, Minimum rise time and amplitude requirements apply at low frequencies.
 

Acquisition - Analog Channels

Sample Rate (Single-shot) 10 GS/s on 4 Ch with Enhanced Sample Rate
Sample Rate (Repetitive) 125 GS/s for repetitive signals (20 ps/div to 10 ns/div)
Memory Length (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
50M / 50M / 50M
(30,000)
Memory Length Options (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
L- Option:
100M / 100M / 100M
(60,000)
XL - Option:
250M / 250M / 250M
(65,000)
Intersegment Time 1 µs
Averaging Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
Enhanced Resolution (ERES) From 12.5 to 15 bits vertical resolution
Envelope (Extrema) Envelope, floor, or roof for up to 1 million sweeps
Interpolation Linear or Sin x/x (2 pt and 4 pt); 5 or 10 GS/s Enhanced Sample Rate defaults to 2pt or 4pt Sin x/x respectively
 

Triggering System

Modes Normal, Auto, Single, and Stop
Sources Any input channel, Ext, Ext/10, or line; slope and level unique to each source (except line trigger)
Coupling DC, AC, HFRej, LFRej
Pre-trigger Delay 0-100% of memory size (adjustable in 1% increments of 100 ns)
Post-trigger Delay 0-10,000 Divisions in real time mode, limited at slower time/div settings or in roll mode
Hold-off From 2 ns up to 20 s or from 1 to 99,999,999 events
Trigger and Interpolator Jitter ≤ 4 psrms (typical)
<0.1 ps RMS (typical, software assisted)
Internal Trigger Level Range ±4.1 div from center (typical)
External Trigger Level Range Ext (±0.4 V); Ext/10 (±4 V)
Maximum Trigger Rate 1,000,000 waveforms/second (in Sequence Mode, up to 4 channels)
Trigger Sensitivity with Edge Trigger ProBus Inputs 2 div @ < 350 MHz
1 div @ < 200 MHz
0.9 div @ < 10 MHz
(DC, AC, and LFRej coupling, ≥ 2 mV/div, 50 Ω)
Trigger Sensitivity with Edge Trigger (Aux Input) 2 div @ < 350 MHz
1 div @ < 200 MHz
0.9 div @ < 10 MHz
(DC, AC, and LFRej coupling)
Max. Trigger Frequency, SMART Trigger 350MHz
 

Trigger Types

Edge Triggers when signal meets slope (positive, negative, or either) and level condition.
Width Triggers on positive or negative glitches with selectable widths.
minimum width 1.5ns, Maximum Width: 20s
Glitch Triggers on positive or negative glitches with selectable widths. minimum width 1.5ns, Maximum Width: 20s
Window Triggers when signal exits a window defined by adjustable thresholds
Pattern Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern.
TV-Composite Video Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative).
Runt Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew Rate Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
Interval Triggers on intervals selectable between 1 ns and 20 s.
Dropout Triggers if signal drops out for longer than selected time between 1 ns and 20 s.
Measurement Trigger Select from a large number of measurement parameters trigger on a measurement value with qualified limits. Can be used as only trigger or last event in a Cascade Trigger.
Multi-Stage: Qualified (Timeout or State/Edge Qualified) Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events.
Triggers with Exclusion Technology Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
Multi-Stage: Qualified First In Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events.
Multi-Stage: Cascade (Sequence) Trigger, Capability Arm on "A" event, then Trigger on "B" event. Or Arm on "A" event, then Qualify on "B" event, and Trigger on "C" event.
Multi-Stage: Cascade (Sequence) Trigger, Types Cascade A then B: Edge, Window, Pattern (Logic) Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage B only.
Cascade A then B then C (Measurement): Edge, Window, Pattern (Logic), Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage C only.
Cascade A then B then C: Edge, Window, Pattern (Logic)
Multi-Stage: Cascade (Sequence) Trigger, Holdoff Holdoff between A and B or B and C is selectable by time or number of events.
Measurement trigger selection as the last stage in a Cascade precludes a holdoff setting between the prior stage and the last stage.
TriggerScan A Trigger Trainer analyzes the waveforms, identifies normal behavior, and then sets up a large set of rare event smart trigger setups that target abnormal behavior. The trainer ‘learns’ trigger setups based on slew rates, periods, amplitudes outside of a range and then applies them sequentially.
 

Low Speed Serial Protocol Trigger (Optional)

Supported Protocols I2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN1.1, CAN2.0, CAN FD, LIN, FlexRay, MIL-STD-1553, AudioBus (I2S, LJ, RJ, TDM), USB1.x/2.0
 

Measurement Tools

Measurement Functionality Display up to 8 measurement parameters together with statistics, including mean, minimum, maximum, standard deviation, and total number. Each occurrence of each parameter is measured and added to the statistics table. Histicons provide a fast, dynamic view of parameters and waveshape characteristics. Parameter math allows addition, subtraction, multiplication, or division of two different parameters. Parameter gates define the location for measurement on the source waveform. Parameter accept criteria define allowable values based on range setting or waveform state.
Measurement Parameters - Horizontal + Jitter Cycles (number of), Delay (from trigger, 50%), Δ Delay (50%), Duty Cycle (50%, @level), Edges (number of, @level), Fall Time (90-10, @levels), Frequency (50%, @level), Half Period (@level), Hold Time (@level), N Cycle Jitter (peak-peak), Number of Points, Period (50%, @level), Δ Period (@level), Phase (@level), Rise Time (10-90, @levels), Setup (@levels), Skew (@levels), Slew Rate (@levels), Time Interval Error (@level), Time (@level), Δ Time (@level), Width (50%, @level), Δ Width (@level), X(value)@max, X(value)@min
Measurement Parameters - Vertical Amplitude, Base, Level@X, Maximum, Mean, Median, Minimum, Peak-to-Peak, RMS, Std. Deviation, Top.
Measurement Parameters - Pulse Area, Base, Fall Time (90-10, 80-20, @levels), Overshoot (positive, negative), Rise Time (10-90, 80-20, @levels), Top, Width (50%)
Measurement Parameters - Statistical (on Histograms) Full Width (@ Half Max, @ %), Amplitude, Base, Peak @ Max Population, Maximum, Mean, Median, Minimum, Mode, Range, RMS, Std. Deviation, Top, X(value)@Peak, Peaks (number of), Percentile, Population (@bin, total)
 

Math Tools

Math Functionality Display up to 8 math functions traces (F1-F8). The easy-to-use graphical interface simplifies setup of up to two operations on each function trace, and function traces can be chained together to perform math-on-math.
Math Operators - Basic Math Average (summed), Average (continuous), Difference (-), Envelope, Floor, Invert (negate), Product (x), Ratio (/), Reciprocal, Rescale (with units), Roof, Sum (+).
Math Operators - Filters Enhanced resolution (to 15 bits vertical), Interpolate (cubic, quadratic, sinx/x), (SinX)/x.
Math Operators - Frequency Analysis FFT (power spectrum, magnitude, phase, power density, real, imaginary, magnitude squared), up to full record length. Select from Rectangular, VonHann, Hamming, FlatTop and Blackman Harris windows.
Math Operators - Functions Absolute value, Correlation (two waveforms), Derivative, Deskew (resample), Exp (base e), Exp (base 10), Integral, Invert (negate), Log (base e), Log (base 10), Reciprocal, Rescale (with units), Square, Square root, Zoom (identity).
Math Operators - Other Segment, Sparse
 

Measurement and Math Integration

Measurement and Math Integration Histograms to display statistical distributions of up to 2 billion measurement parameters. Trend (datalog) of up to 1 million measurement parameters. Track (display parameter vs. time, time-correlated to acquisitions) any parameter. Persistence histogram and persistence trace (mean, range, sigma)
 

Pass/Fail Testing

Pass/Fail Testing Display up to 8 pass/fail queries using a Single or Dual Parameter Comparison (compare All values, or Any value <. ≤, =, >, ≥, within limit ±Δ value or %) or Mask Test (pre-defined or user-defined mask, waveform All In, All Out, Any In, or Any Out conditions). Combine queries into a boolean expression to Pass or Fail IF "All True", "All False", "Any True", "Any False", or groups or "All" or "Any", with following THEN Save (waveforms), Stop, Alarm, (send) Pulse, Hardcopy (send email, save screen image, save to clipboard, send to printer), or (save) LabNotebook.
 

Display System

Size Color 12.1" widescreen flat panel TFT-Active Matrix with high resolution touch screen
Resolution WXGA; 1280 x 800 pixels.
Number of traces Display a maximum of 16 traces. Simultaneously display channel, zoom, memory and math traces.
Grid Styles Auto, Single, Dual, Quad, Octal, Tandem, Quattro, Twelve, Sixteen, X-Y, Single+X-Y, Dual+X-Y
Waveform Representation Sample dots joined, or sample dots only
 

Persistence Display

Analog and Color-Graded Persistence Variable saturation levels; stores each trace’s persistence data in memory
Persistence Types Select analog, color, or three-dimensional
Trace Selection Activate persistence on all or any combination of traces
Persistence Aging Select from 500 ms to infinity
Sweep Display Modes All accumulated, or all accumulated with last trace highlighted
 

Zoom Expansion Traces

Zoom Expansion Traces Display up to 8 Zoom and 8 Math/Zoom traces
 

Internal Waveform Memory

Internal Waveform Memory 4 active waveform memory traces (M1-M4) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.
 

Setup Storage

Front Panel and Instrument Status Store to the internal hard drive, over the network, or to a USB-connected peripheral device.
 

Automatic Setup

Auto Setup Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical Scale Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range
 

Calibration

Calibration Stability Calibration ensured within +/-5°C operating temperature. Manual calibration may be invoked if outside this temperature range.
 

Processor/CPU

Type Intel® CoreTM i7-2710QE Quad, 2.1 GHz (3.0 GHz in turbo mode) (or better)
Processor Memory 16 GB standard
Operating System Microsoft Windows® 7 Pro 64 bit Embedded
Oscilloscope Operating Software Teledyne LeCroy MAUI™ with OneTouch
Real Time Clock Date and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks.
 

Connectivity

Ethernet Port Supports 2 10/100/1000BaseT Ethernet interface (RJ45 ports)
USB Host Ports Minimum 6 total (incl. 2 front panel) USB 2.0 ports support Windows compatible devices
USB Device Port 1 USBTMC port
GPIB Port (optional) Supports IEEE - 488.2 (External)
External Monitor Port 15 pin D-Type WXGA compatible DB-15 to support customer-supplied external monitor.
Includes support for extended desktop operation with WXGA resolution on second monitor.
Supports touch screen integration of external monitor (Note: external display can not use a Fujitsu touch-screen driver).
Remote Control Via Windows Automation, or via LeCroy Remote Command Set
 

Auxiliary Input

Signal Types Select External Trigger or External Clock Input on the front panel
Coupling 50 Ω: DC; 1 MΩ: AC, DC, GND
Max. Input Voltage 50 Ω: 5 Vrms; 1 MΩ: 400 Vmax (DC + Peak AC ≤ 5 kHz)
 

Auxiliary Output

Signal Types Select from control signals or Off
Output Signal 500 Hz-1 MHz square wave or DC level; 50 mV-1 V into 1 MΩ
Control Signals Trigger enabled, trigger out, pass/fail status, off
Connector Type BNC, located on rear panel
 

Probes

Probes Qty. (4) ÷10 Passive Probes
Probe System ProBus. Automatically detects and supports a variety of compatible probes
Scale Factors Automatically or manually selected depending on probe used
Calibration Output Default is 1kHz square wave, 1Vp-p (typical), output to probe hook. Settable from 250 Hz to 1 MHz square wave; 50 mV to 1.0V.
 

Power Requirements

Voltage 100-240 VAC ±10% at 45-66 Hz; 110-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection; Installation Category 300 V CAT II
Nominal Power Consumption 200 W / 200 VA
Max. Power Consumption 320 W / 320 VA (with all PC peripherals and active probes connected to 4 channels)
 

Environmental

Temperature (Operating) +5 °C to +40 °C
Temperature (Non-Operating) -20 °C to +60 °C
Humidity (Operating) 5% to 80% relative humidity (non-condensing) up to +31 °C.
Upper limit derates to 50% relative humidity (non-condensing) at +40 °C.
Humidity (Non-Operating) 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating) Up to 10,000 ft. (3048 m) at or below +30 °C
Altitude (Non-Operating) Up to 40,000 ft. (12,192 m)
Random Vibration (Operating) 0.31 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Random Vibration (Non-Operating) 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Functional Shock 30 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
 

Size and Weight

Dimensions (HWD) 11.48"H x 15.72"W x 5.17"D (291.7 mm x 399.4 mm x 131.31 mm)
Weight 12.9 lbs. (5.86 kg)
Shipping Weight 20.2 lbs. (9.2 kg)
 

Certifications

CE Certification
UL and cUL Listing
CE Compliant, UL and cUL listed; conforms to
UL 61010-1 (3rd Edition), UL 61010-2-030 (1st Edition)
CAN/CSA C22.2 No. 61010-1-12,
 

Warranty and Service

Warranty and Service 3-year warranty; calibration recommended annually.
Optional service programs include extended warranty, upgrades, and calibration services.
 

SAM40

SAM40-8
Sensor Acquisition Module, 8 input channels, 40 kHz bandwidth. Must be used with 12-bit HDO.
SAM40-16
Sensor Acquisition Module, 16 input channels, 40 kHz bandwidth. Must be used with 12-bit HDO.
SAM40-24
Sensor Acquisition Module, 24 input channels, 40 kHz bandwidth. Must be used with 12-bit HDO.

Memory Options

HDO6KA-L
100 Mpt/Ch Memory Option for HDO6000A
HDO6KA-XL
250 Mpt/Ch Memory Option for HDO6000A

Computer Upgrade

HDO6kA-RSSD
Removable Solid State Drive Package for HDO6000A (includes removable solid state drive kit and two solid state drives)
HDO6kA-SSD-02
Replacement Removable Solid State Drive for HDO6000A

Remote Control/Network Options

USB2-GPIB
External USB 2.0 to GPIB IEEE 488.2 adapter

Power Analysis Software

HDO6k-DIG-PWR-MGMT
Digital Power Management Analysis Software Option
HDO6K-PWR
Power Analysis Option for HDO6000

Serial Trigger and Decode

HDO6K-1553 TD
MIL-STD-1553 Trigger and Decode Option for HDO6000
HDO6K-1553 TDME
MIL-STD-1553 Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6k-SPMIbus D
SPMI Decode for HDO6000 Series
HDO6K-MDIObus D
MDIO Decode for HDO6000 Series
HDO6k-ARINC429BUS DME SYMBOLIC
ARINC 429 Bus Symbolic Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-ARINC429BUS Dsymbolic
ARINC 429 Bus Symbolic Decode option for HDO6000
HDO6K-Audiobus TD
AudioBus trigger and decode option for HDO6000
HDO6K-Audiobus TDG
AudioBus trigger, decode, and graph option for HDO6000
HDO6K-CAN FDbus TD
CAN and CAN FD Trigger and Decode Option for HDO6000
HDO6K-CAN FDBUS TDME
CAN and CAN FD Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-CAN FDBUS TDME SYMBOLIC
CAN and CAN FD Symbolic Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-CANbus TD
CAN Trigger and Decode Option for HDO6000
HDO6K-CANBUS TDME
CAN Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-CANBUS TDME SYMBOLIC
CAN Symbolic Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-DigRF3Gbus D
DigRF 3G Bus Decode option for HDO6000
HDO6K-DigRFv4bus D
DigRF V4 Bus Decode option for HDO6000
HDO6K-DPHYbus D
D-PHY Bus Decode option for HDO6000
HDO6K-EMB TD
Bundle: Includes I2C, SPI, UART-RS232 Trigger and Decode Options for HDO6000
HDO6K-EMB TDME
Bundle: Incl. I2C, SPI, UART-RS232 Trigger, Decode, Measure/Graph, and Eye Diagram Opt. for HDO6000
HDO6K-EMB TDME
Bundle: Incl. I2C, SPI, UART-RS232 Trigger, Decode, Measure/Graph, and Eye Diagram Opt. for HDO6000
HDO6K-ENETbus D
ENET Bus Decode Option for HDO6000
HDO6K-FlexRaybus TD
FlexRay Trigger and Decode Option for HDO6000
HDO6K-FLEXRAYBUS TDMP
FlexRay Trigger, Decode, Measure/Graph and Physical Layer Option for HDO6000
HDO6K-I2Cbus TD
I2C Trigger and Decode Option for HDO6000
HDO6K-I2CBUS TDME
I2C Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-LINbus TD
LIN Trigger and Decode Option for HDO6000
HDO6K-LINBUS TDME
LIN Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-Manchesterbus D
Manchester Bus Decode Option for HDO6000
HDO6K-NRZbus D
NRZ Bus Decode Option for HDO6000
HDO6K-PROTOBUS MAG
Serial Debug Toolkit - Measure Analyze Graph for HDO6000
HDO6K-SENTbus D
SENT Bus Decode Option for HDO6000
HDO6K-SpaceWirebus D
SpaceWire Decode Option for HDO6K series
HDO6K-SPIbus TD
SPI Trigger and Decode Option for HDO6000
HDO6K-SPIBUS TDME
SPI Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-UART-RS232bus TD
UART-RS232 Trigger and Decode Option for HDO6000
HDO6K-UART-RS232BUS TDME
UART-RS232 Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-USB2-HSICbus D
USB 2.0 HSIC Decode Option for HDO6000
HDO6K-USB2bus TD
USB 2.0 Trigger and Decode Option for HDO6000
HDO6k-USB2BUS TDME
USB 2.0 Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000

Jitter Analysis Software

HDO6K-JITKIT
Clock, clock-data Jitter Analysis and views of time, statistical, spectral, and jitter overlay

Digital Filtering Software

HDO6K-DFP2
Digital Filter Software Package for HDO6000

Serial Data Compliance

GRL-USB-PD
GRL USB Power Delivery Compliance Test Software
GRL-USB-PD-C1
GRL USB Type-C Test Controller
HDO6K-ET-PMT
Electrical Telecom Mask Test Package

Serial Data Analysis

HDO6K-SDM
Serial Data Mask Software Package for HDO6000

Other Software Options

HDO6K-VECTORLINQ
VectorLinQ Vector Signal Analysis
HDO6K-EMC
EMC Pulse Parameter Software Package for HDO6000
HDO6K-XDEV
Advanced Customization Option for HDO6000

Miscellaneous

OC1021-A
Instrument Cart
HDO6K-POUCH
HDO6000 Accessory Pouch
HDO6K-SOFTCASE
HDO6000 Soft Carrying Case
HDO6K-RACK
HDO6000 Rack Mount Accessory
HDO6K-FP-CHNES-SI
HDO6000 Simplified Chinese Front Panel Overlay
HDO6K-FP-CHNES-TR
HDO6000 Traditional Chinese Front Panel Overlay
HDO6K-FP-FRENCH
HDO6000 French Front Panel Overlay
HDO6K-FP-GERMAN
HDO6000 German Front Panel Overlay
HDO6K-FP-ITALIAN
HDO6000 Italian Front Panel Overlay
HDO6K-FP-JAPANESE
HDO6000 Japanese Front Panel Overlay
HDO6K-FP-KOREAN
HDO6000 Korean Front Panel Overlay
HDO6K-FP-RUSSIAN
HDO6000 Russian Front Panel Overlay
HDO6K-FP-SPANISH
HDO6000 Spanish Front Panel Overlay

Mixed Signal Accessories

PK400-0
Extra Large Gripper Probe Set . Includes 22 probes
PK400-1
Large Gripper Probe Set for 0.10 inch (2.54mm) pin pitch. Includes 10 probes with color coded leads
PK400-2
Medium Gripper Probe Set for 0.04 inch (1.0mm) pin pitch. Includes 10 probes with color coded leads
PK400-3
Small Gripper Probe Set for 0.008 inch (0.2 mm) pin pitch. Includes 10 probes with color coded leads

Active Voltage Probes

ZS1500-QUADPAK
Set of 4 ZS1500, 1.5 GHz High Impedance Active Probes
ZS1000-QUADPAK
Set of 4 ZS1000, 1 GHz High Impedance Active Probes
ZS1500
1.5 GHz, 0.9 pF, 1 MOhm Active Voltage Probe
ZS1000
1 GHz, 0.9 pF, 1 MOhm Active Voltage Probe

Differential Probes (<= 1.5 GHz)

AP033
500 MHz Differential Probe
ZD200
200 MHz, 3.5 pF, 1 MOhm Active Differential Probe, ±20 V
ZD500
500 MHz, 1.0 pF Active Differential Probe, ±8 V
ZD1000
1 GHz, 1.0 pF Active Differential Probe, ±8 V
ZD1500
1.5 GHz, 1.0 pF Active Differential Probe, ±8 V

Current Probes

DCS015
Deskew Calibration Source for CP031,CP031A, CP030, CP030A and AP015 Limited Availability
CP150
150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 2 meter cable
CP500
500 A, 2 MHz Current Probe - AC/DC, 500 A rms, 700 A Peak Pulse, 6 meter cable
CP030
30A, 50 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP031
30A, 100 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP030A
30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP031A
30A, 100 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CA10
Programmable Current Sensor to ProBus Adapter for use with third party current sensors
CA10-QUADPAK
Set of 4 CA10 Programmable Current Sensor to ProBus Adapters for third-party current sensors
CP030-3M
30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 3 meter cable
CP150-6M
150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 meter cable
DCS025
Deskew Calibration Source for CP030, CP030A, CP031, CP031A, AP015, CP150, CP500

High Voltage Passive Probes

PPE4KV
100:1 400 MHz 50 MOhms High-Voltage Probe
PPE5KV
100:1 400 MHz 50 MOhms High-Voltage Probe
PPE6KV
1000:1 400 MHz 50 MOhms High-Voltage Probe
HVP120
400 MHz, 1kV Vrms High-Voltage Passive Probe

Passive Probes

PP018-1
500 MHz Passive Probe for HDO, 10:1, 10 MOhm
PP023-1
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP026-1
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm

High Voltage Differential Probes

AP031
700 V, 25 MHz High-Voltage Differential Probe (÷10, ÷100)
ADP300
1kV, 20 MHz High-Voltage Differential Probe
ADP305
1kV, 100 MHz High-Voltage Differential Probe
HVD3102
1kV, 25 MHz High Voltage Differential Probe
HVD3106
1kV, 120 MHz High Voltage Differential Probe
HVD3106-6M
1kV, 80 MHz High Voltage Differential Probe with 6m cable
HVD3605
6kV, 100 MHz High Voltage Differential Probe
HVD3102-NOACC
1kV, 25 MHz High Voltage Differential Probe without tip Accessories
HVD3106-NOACC
1kV, 120 MHz High Voltage Differential Probe without tip Accessories
HVD3206
2kV, 120 MHz High Voltage Differential Probe
HVD3206-6M
2kV, 80 MHz High Voltage Differential Probe with 6m cable

Differential Amplifiers

DA1855A
1 Ch, 100 MHz Differential Amplifier with Precision Voltage Source
DXC100A
÷100 or ÷10 Selectable, 250 MHz Passive Differential Probe Pair
DXC200
÷1, 50 MHz, Passive Differential Probe Pair
DXC-5100
100:1 250 MHz 40 Mohm 2.75pf Differential Probe Pair;
DA101
10:1 1 MOhm Passive Attenuator
DA1855A-PR2
2 Ch, 100 MHz, Differential Amplifier with Precision Voltage Source
DA1855A-PR2-RM
2 Ch, DA1855A with Rackmount (must be ordered at time of purchase, no retrofit)
DA1855A-RM
DA1855A with rackmount;

Probe Parts and Kits

PACC-ZD008
Y-Lead Adapter
PACC-ZD001
Y lead Adapter for ZD differential probes - Qty 1
PACC-ZD002
Solder-in lead for ZD differential probe - QTY 2
PACC-ZD003
Long spring ground for ZD differential probe - QTY 2
PACC-ZD004
Tip saver for ZD differential probe - QTY 2
PACC-ZD005
Swivel tip adapter for ZD differential probe - QTY 1
PACC-ZD006
Small IC adapter for ZD differential probe - QTY 2
PACC-ZD007
Replacement Accessory kit for ZD200
PK111
Replacement Accessory kit for ZD500, ZD1000, and ZD1500
PKIT4-5MM-101
Standard Accessory Replacement Kit for PP017/PP018

Probe Adapters

CA10
Programmable Current Sensor to ProBus Adapter for use with third party current sensors
TPA10
TekProbe to ProBus Probe Adapter
TPA10-QUADPAK
Set of 4 TPA10 TekProbe to ProBus Probe Adapters. Includes soft carrying case.

Active Voltage Rail Probe

RP4030
Power/Voltage Rail Probe. 4 GHz bandwidth, 1.2x attenuation, +/-30V offset, +/-800mV Includes a complete set of solder-in leads, coaxial cables, and PCB mounts.
RP4000-MCX-LEAD-SI
Qty. 3 MCX 4 GHz solder-in lead accessories (additional to those supplied with RP4030), 18cm long
RP4000-MCX-PCBMOUNT
Qty. 10 MCX 6mm x 6mm PCB mounts (additional to those supplied with RP4030)
RP4000-MCX-CABLE-UFL
Qty. 3 3 GHz MCX to U.FL ultra-miniature coax cable, 8cm long (add'l to those supplied with RP4030)
RP4000-UFL-PCBMOUNT
Qty. 10 U.FL 3mm x 3mm PCB mounts (additional to those supplied with RP4030)
RP4000-BROWSER
RP4030 350 MHz Browser Tip accessory. Includes 0 Ohm (1x), 450 Ohm (10x) and 950 Ohm (20x) tips.

High Voltage Fiber Optically-isolated Probes

HVFO103
High Voltage Fiber Optic Probe, 60 MHz Bandwidth. Includes soft-carrying case. Requires attenuating tip (ordered separately). Includes Qty. 1 1m Fiber Optic Cable.
HVFO100-1X-TIP
HVFO103 +/-1V (1x Attenuation) Tip Accessory
HVFO100-5X-TIP
HVFO103 +/-5V (5x Attenuation) Tip Accessory
HVFO100-20X-TIP
HVFO103 +/-20V (20x Attenuation) Tip Accessory
HVFO100-40X-TIP
HVFO103 +/-40V (40x Attenuation) Tip Accessory
HVFO103-XMITTER
HVFO103 Spare Amplifier/Modulating Transmitter
HVFO-1M-FIBER
HVFO 1m Fiber Optic Cable Accessory
HVFO-2M-FIBER
HVFO 2m Fiber Optic Cable Accessory
HVFO-6M-FIBER
HVFO 6m Fiber Optic Cable Accessory