Products
Oscilloscopes

WaveSurfer 510

1 GHz, 10 GS/s, 4 Ch, 16 Mpts/Ch DSO with 12.1" Touch Screen Display. 10 GS/s, 32 Mpts Interleaved


WaveSurfer 510   (1 GHz Bandwidth, 4 Input Channels, 10 GS/s)
Quick Specs
Bandwidth1 GHz
Sample Rate10 GS/s on 4Ch
Maximum Acquisition Memory32 Mpts (2 Ch operation)
Input Channels4
Vertical Resolution8-bits
Check up to three models.
Key Features
  • 1 GHz, 10 GS/s, up to 16 Mpts/ch
  • MAUI with OneTouch
    • Designed for touch
    • Built for simplicity
    • Made to solve
  • WaveScan - Advanced Search and Find
  • LabNotebook Documentation and Report
  • Generation
  • History Mode - Waveform Playback
  • Sequence Mode Segmented Memory
  • Spectrum Analyzer Mode
  • Power Analysis Software
  • Serial Trigger and Decode
    • I2C, SPI, UART
    • CAN, LIN, FlexRay, SENT
    • Ethernet 10/100BaseT, USB 1.0/1.1/2.0, USB2.0-HSIC
    • Audio (I2S, LJ, RJ, TDM)
    • MIL-STD-1553, ARINC 429
    • MIPI D-PHY, DigRF 3G, DigRF v4
    • Manchester, NRZ

 

MAUI - A New Wave of Thinking

MAUI is the most advanced oscilloscope user interface. MAUI is designed for touch; all important oscilloscope controls are accessed through the intuitive touch screen. MAUI is built for simplicity; time saving shortcuts and intuitive dialogs simplify setup. MAUI is made to solve; deep set of debug and analysis tools help identify problems and find solutions quickly.

Uncompromised Performance

Many 1 GHz oscilloscopes are available at attractive entry-point prices, however, they are often limited in sample rate, memory or features. The WaveSurfer 10 provides uncompromised 1 GHz performance with up to 10 GS/s per channel and 32 Mpts of memory.

Mixed Signal - No Compromises

Debug complex embedded designs with integrated 18 channel mixed signal capability

Identify and Isolate Problems Fast

Quickly locate analog or digital waveforms for runts, glitches or other anomolies with WaveScan

History Mode Waveform Playback

Scroll back in time to isolate anomalies and quickly find the source of the problem.

Touch Screen Simplicity

Easily control channels, trigger, math and measurements with the large multi-touch display and intuitive interface.

Sequence Mode

Capture many fast pulses in quick succession or events separated by long periods of time.

Serial Bus Trigger and Decode

View decoded protocol information on top of physical layer waveforms and trigger on protocol specific messages

Save, Document, Report

Save all results and data with a single button press and create custom reports with LabNotebook

Simple Power Measurements

Measure and analyze operating characteristics of power conversion devices and circuits

Spectrum Analyzer Interface

View signal details in the frequency domain with a spectrum analyzer style user interface

Advanced Math and Measure

Use automatic measurement parameters and math functions to understand every waveform detail

Vertical - Analog Channels

Analog Bandwidth (Max) 1 GHz
Analog Bandwidth @ 50 Ω (-3 dB) (ProBus Input) 1 GHz
(≥2 mV/div)
Analog Bandwidth @ 1 MΩ (-3 dB) (ProBus Input) 500 MHz (typical)
Rise Time (10-90%, 50 Ω) 415 ps (typical)
Rise Time (20-80%, 50 Ω) 290 ps (typical)
Input Channels 4
Vertical Resolution 8 bits; up to 11 bits with enhanced resolution (ERES)
Sensitivity 50 Ω: 1 mV-1 V/div, fully variable;
1 MΩ: 1 mV-10 V/div, fully variable
DC Vertical Gain Accuracy (Gain Component of DC Accuracy) ±(1%) F.S, offset at 0 V
Channel-Channel Isolation DC up to rated BW: 40 dB (>100:1),
(For any two ProBus input channels, same v/div settings, typical)
Offset Range 50 Ω
±1.6 V @ 1 mV - 4.95 mV/div
±4 V @ 5 mV - 9.9 mV/div
±8 V @ 10 mV - 19.8 mV/div
±10 V @ 20 mV - 1 V/div

1 MΩ
±1.6 V @ 1 mV - 4.95 mV/div
±4 V @ 5 mV - 9.9 mV/div
±8 V @ 10 mV - 19.8 mV/div
±16 V @ 20 mV - 100 mV/div
±80 V @ 102 mV - 1.0 V/div
±160 V @ 1.02 V - 10 V/div
DC Vertical Offset Accuracy ±(1.5% of offset setting +1% of full scale + 1 mV) (test limit)
Maximum Input Voltage 50 Ω: 5V RMS ± 10V peak
1 MΩ: 400 V max. (DC + peak AC < 10 kHz)
Input Coupling 1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Input Impedance 50 Ω+/-2% or 1 MΩ||17pF, 10 MΩ || 9.5 pF with supplied Probe
Bandwidth Limiters 20MHz, 200MHz
 

Horizontal - Analog Channels

Timebases Internal timebase common to 4 input channels; an external clock may be applied at the EXT input
Acquisition Modes Real-time, Roll, Random Interleaved Sampling (RIS), Sequence
Time/Division Range 200 ps/div - 1000 s/div
RIS available at ≤ 10 ns/div;
Roll Mode available at ≥ 100 ms/div and ≤ 5 MS/s
Clock Accuracy <=1.5 ppm +(aging of 0.5 ppm/yr from last calibration)
Sample Clock Jitter up to 10µs Acquired Time Range:
100fsrms (Internal Timebase Reference)

up to 10ms Acquired Time Range:
360fsrms (Internal Timebase Reference)
Delta Time Measurement Accuracy \sqrt{2}*\sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2) (RMS)+(clock accuracy*reading)(seconds)
Jitter Measurement Floor \sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2\; seconds\; rms\; (TIE)}
Channel-Channel Deskew Range ±9 x time/div. setting, 100 ms max., each channel
 

Acquisition - Analog Channels

Sample Rate (Single-shot) 10 GS/s on 4Ch
Sample Rate (Repetitive) 50 GS/s for repetitive signals (20 ps/div to 10 ns/div)
Memory Length (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
16M / 32M / 32M
(5,000)
Intersegment Time 1 µs
Averaging Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
Enhanced Resolution (ERES) From 8.5 to 11 bits vertical resolution
Envelope (Extrema) Envelope, floor, or roof for up to 1 million sweeps
Interpolation Linear or Sin x/x
 

Triggering System

Modes Normal, Auto, Single, and Stop
Sources Any input channel, Ext, Ext/10, Line or Fast Edge; slope and level unique to each source (except line trigger)
Coupling DC, AC, HFRej, LFRej
Pre-trigger Delay 0-100% of memory size (adjustable in 1% increments of 100 ns)
Post-trigger Delay 0-10,000 divisions in real time mode, limited at slower time/div settings or in roll mode
Hold-off From 2 ns up to 20 s or from 1 to 99,999,999 events
Trigger and Interpolator Jitter ≤ 3.5 ps RMS (typical)
Internal Trigger Level Range ±4.1 div from center (typical)
External Trigger Level Range Ext (±0.4 V); Ext/10 (±4 V)
Maximum Trigger Rate 1,000,000 waveforms/second (in Sequence Mode, up to 4 channels)
Trigger Sensitivity with Edge Trigger ProBus Inputs 2 div @ < 1 GHz
1.5 div @ < 500 MHz
1 div @ < 200 MHz
0.9 div @ < 10 MHz
(DC, AC, and LFRej coupling, ≥ 10 mV/div, 50 Ω)
Trigger Sensitivity with Edge Trigger (Aux Input) 2 div @ <1 GHz
1.5 div @ < 500 MHz
1 div @ < 200 MHz
0.9 div @ < 10 MHz
(DC, AC, and LFRej coupling)
Max. Trigger Frequency, SMART Trigger 1.0 GHz @ ≥ 10 mV/div
(minimum triggerable width 750 ps)
 

Trigger Types

Edge Triggers when signal meets slope (positive, negative, or either) and level condition.
Width Triggers on positive or negative glitches with selectable widths.
Minimum width 500 ps, maximum width: 20 s
Glitch Triggers on positive or negative glitches with selectable widths. Minimum width 200 ps, maximum width: 20 s
Window Triggers when signal exits a window defined by adjustable thresholds
Pattern Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern.
TV-Composite Video Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative).
Runt Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew Rate Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
Interval Triggers on intervals selectable between 1 ns and 20 s.
Dropout Triggers if signal drops out for longer than selected time between 1 ns and 20 s.
Multi-Stage: Qualified (Timeout or State/Edge Qualified) Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events.
Triggers with Exclusion Technology Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
 

Low Speed Serial Protocol Trigger (Optional)

Supported Protocols I2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN1.1, CAN2.0, CAN FD, LIN, FlexRay, MIL-STD-1553, AudioBus (I2S, LJ, RJ, TDM), USB1.x/2.0, SATA
 

Measurement Tools

Measurement Functionality Display up to 6 measurement parameters together with statistics, including mean, minimum, maximum, standard deviation, and total number. Each occurrence of each parameter is measured and added to the statistics table. Histicons provide a fast, dynamic view of parameters and waveshape characteristics. Parameter gates define the location for measurement on the source waveform.
Measurement Parameters - Horizontal + Jitter Delay (from trigger, 50%), Duty Cycle, Edges , Fall Time (90-10, 80-20), Frequency, Period, Δ Period, Phase, Rise Time (10-90, 20-80), Skew, Width+, Width-
Measurement Parameters - Vertical Amplitude, Base, Maximum, Mean, Minimum, Peak-to-Peak, RMS, Std. Deviation, Top.
Measurement Parameters - Pulse Area, Base, Fall Time (90-10, 80-20), Overshoot (positive, negative), Rise Time (10-90, 80-20), Top, Width+, Width-
 

Math Tools

Math Functionality Display up to 2 math functions traces (F1-F2). The easy-to-use graphical interface simplifies setup of up to two operations on each function trace, and function traces can be chained together to perform math-on-math.
Math Operators - Basic Math Average (summed), Average (continuous), Difference (-), Envelope, Floor, Invert (negate), Product (x), Ratio (/), Reciprocal, Rescale (with units), Roof, Sum (+).
Math Operators - Filters Enhanced resolution (to 11 bits vertical)
Math Operators - Frequency Analysis FFT (power spectrum, magnitude), up to full record length. Select from Rectangular, VonHann, Hamming, FlatTop and Blackman Harris windows.
Math Operators - Functions Absolute value, Derivative, Integral, Invert (negate), Reciprocal, Rescale (with units), Square, Square root, Zoom (identity).
 

Measurement and Math Integration

Measurement and Math Integration Trend (datalog) of up to 1 million measurement parameters.
 

Pass/Fail Testing

Pass/Fail Testing Mask Test (pre-defined or user-defined mask, waveform All In, All Out, Any In, or Any Out conditions) with following THEN Save (waveforms), Stop, Alarm, (send) Pulse, Hardcopy (send email, save screen image, save to clipboard, send to printer), or (save) LabNotebook.
 

Display System

Size Color 12.1" widescreen flat panel TFT-Active Matrix with high resolution touch screen
Resolution WXGA; 1280 x 800 pixels.
Number of traces Display a maximum of 16 traces. Simultaneously display channel, zoom, memory and math traces.
Grid Styles Auto, Single,X-Y, Single+X-Y
Waveform Representation Sample dots joined, or sample dots only
 

Persistence Display

Analog and Color-Graded Persistence Variable saturation levels; stores each trace’s persistence data in memory
Persistence Types Select analog, color, or three-dimensional
Trace Selection Activate persistence on all or any combination of traces
Persistence Aging Select from 500 ms to infinity
Sweep Display Modes All accumulated, or all accumulated with last trace highlighted
 

Zoom Expansion Traces

Zoom Expansion Traces Display up to 4 Zoom and 2 Math/Zoom traces
 

Internal Waveform Memory

Internal Waveform Memory 4 active waveform memory traces (M1-M4) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.
 

Setup Storage

Front Panel and Instrument Status Store to the internal hard drive, over the network, or to a USB-connected peripheral device.
 

Automatic Setup

Auto Setup Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical Scale Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range
 

Calibration

Auto Calibration Ensures specified DC and timing accuracy is maintained for 1 year minimum.
 

Processor/CPU

Type Intel® CoreTM i3-6100 Dual, 3.7 GHz (or better)
Processor Memory 8 GB standard
Operating System Microsoft Windows® 7 For Embedded Systems 64Bits
Oscilloscope Operating Software Teledyne LeCroy MAUI™
Real Time Clock Date and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks.
 

Connectivity

Ethernet Port Supports 2 10/100/1000BaseT Ethernet interface (RJ45 ports)
USB Host Ports 4 side USB 3.1 Gen1 ports, and 1 front USB 3.1 port support Windows compatible devices
GPIB Port (optional) Supports IEEE - 488.2 (External)
External Monitor Port DisplayPort 1.1 and HDMI to support customer-supplied external monitor.
Includes support for extended desktop operation with UHD (3840 x 2160) pixel resolution and split-grid capability on external monitor.
Supports touch screen integration of external monitor (Note: external display can not use a Fujitsu touch-screen driver).
Remote Control Via Windows Automation, or via LeCroy Remote Command Set
Network Communication Standard VXI-11 or VICP, LXI Class C (v1.2) Compliant
 

Auxiliary Input

Signal Types Select External Trigger or External Clock Input on the front panel
Coupling 50 Ω: DC; 1 MΩ: AC, DC, GND
Max. Input Voltage 50 Ω: 5 Vrms; 1 MΩ: 250 Vmax (DC + Peak AC ≤ 10 kHz)
 

Auxiliary Output

Signal Types Select from control signals or Off
Output Signal 500 Hz-1 MHz square wave or DC level; 50 mV-1 V into 1 MΩ
Control Signals Trigger enabled, trigger out, pass/fail status, fast edge, off
Connector Type BNC, located on front
 

Probes

Probes Qty. (4) ÷10 Passive Probes
Probe System ProBus. Automatically detects and supports a variety of compatible probes
Scale Factors Automatically or manually selected depending on probe used
Calibration Output Default is 1kHz square wave, 1Vp-p (typical), output to probe hook. Settable from 500 Hz to 1 MHz square wave; 50 mV to 1.0V.
 

Power Requirements

Voltage 100-240 VAC ±10% at 50/60 Hz ±5%; 110-120 VAC ±10% at 400 Hz ±5%; Automatic AC Voltage Selection
Nominal Power Consumption 285 W / 285 VA
Max. Power Consumption 375 W / 375 VA (with all PC peripherals and active probes connected to 4 channels)
 

Environmental

Temperature (Operating) +5 °C to +40 °C
Temperature (Non-Operating) -20 °C to +60 °C
Humidity (Operating) 5% to 90% relative humidity (non-condensing) up to +31 °C.
Upper limit derates to 50% relative humidity (non-condensing) at +40 °C.
Humidity (Non-Operating) 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating) Up to 10,000 ft. (3048 m) at or below +30 °C
Altitude (Non-Operating) Up to 40,000 ft. (12,192 m)
Random Vibration (Operating) 0.31 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Random Vibration (Non-Operating) 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Functional Shock 30 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
 

Size and Weight

Dimensions (HWD) 12.44"H x 16.42"W x 9.37"D (316 x 417 x 238 mm)
Weight 22.8 lbs. (10.3 kg)
Shipping Weight 37.5 lbs. (17.0 kg)
 

Certifications

CE Certification
UL and cUL Listing
CE Compliant, UL and cUL listed; conforms to
UL 61010-1 (3rd Edition), UL 61010-2-030 (1st Edition)
CAN/CSA C22.2 No. 61010-1-12
 

Warranty and Service

Warranty and Service 3-year warranty; calibration recommended annually.
Optional service programs include extended warranty, upgrades, and calibration services.
 

Mixed Signal Solutions

MS-500
500 MHz, 18 Channels, 2 GS/s, 50 Mpts/ch Mixed Signal Oscilloscope Option
MS-500-36
250 MHz,36 Ch,1 GS/s,25 Mpts/ch (500MHz,18 Ch,2 GS/s,50 Mpts/ch Interleaved) Mixed Signal Option
MS-250
250 MHz, 18 Channels, 1 GS/s, 10 Mpts/ch Mixed Signal Oscilloscope Option

Remote Control/Network Options

USB2-GPIB
External USB 2.0 to GPIB IEEE 488.2 adapter

Power Analysis Software

WS510-PWR
Power Analysis Option for WaveSurfer 510

Serial Trigger and Decode

WS510-1553 TD
MIL-STD-1553 Trigger and decode option for WaveSurfer 510
WS510-ARINC429bus Dsymbolic
ARINC 429 Bus Symbolic Decode option for WaveSurfer 510
WS510-AudioBus TD
AudioBus trigger and decode option for WaveSurfer 510
WS510-AudioBus TD
AudioBus trigger and decode option for WaveSurfer 510
WS510-CAN FDbus TD
CAN and CAN FD Trigger and Decode Option for WaveSurfer 510
WS510-CANbus TD
CAN Trigger and Decode Option for WaveSurfer 510
WS510-DigRF3Gbus D
DigRF 3G Bus Decode option for WaveSurfer 510
WS510-DigRFV4bus D
DigRF V4 Bus Decode option for WaveSurfer 510
WS510-DPHYbus D
D-PHY Bus Decode option for WaveSurfer 510
WS510-EMB
I2C, SPI, UART and RS-232 Trigger and Decode Package
WS510-ENETbus D
ENET Bus Decode Option for WaveSurfer 510
WS510-FlexRaybus TD
FlexRay Trigger and Decode Option for WaveSurfer 510
WS510-I2Cbus TD
I2C Bus Trigger and Decode Option for WaveSurfer 510
WS510-LINbus TD
LIN Bus Trigger & Decode Option for WaveSurfer 510
WS510-Manchesterbus D
Manchester Bus Decode Option for WaveSurfer 510
WS510-NRZbus D
NRZ Bus Decode Option for WaveSurfer 510
WS510-SENTbus D
SENT Bus Decode Option for WaveSurfer 510
WS510-SPIbus TD
SPI Bus Trigger & Decode Option for WaveSurfer 510
WS510-UART-RS232bus TD
UART and RS232 Bus Trigger and Decode Option for WaveSurfer 510
WS510-USB2bus D
USB 2.0 Bus Decode option for WaveSurfer 510
WS510-USB2-HSICbus D
USB 2.0 HSIC Decode Option for WaveSurfer 510
WS510-SpaceWirebus D
SpaceWire Decode Option for WaveSurfer 510
WS510-SPMIbus D
SPMI Decode Option for WaveSurfer 510
WS510-MDIObus D
MDIO Decode Option for WaveSurfer 510

Other Software Options

WS510-Spectrum
Spectrum Analysis Option for WaveSurfer 510

Miscellaneous

OC1021-A
Instrument Cart
WS510-FP-CHNES-SI
WS510 Chinese (Simplified) Front Panel Overlay
WS510-HARDCASE
WS510 Hard Carrying Case
WS510-FP-CHNES-TR
WS510 Chinese (Traditional) Front Panel Overlay
WS510-RACK
WS510 Rack Mount Accessory
WS510-FP-FRENCH
WS510 French Front Panel Overlay
WS510-FP-GERMAN
WS510 German Front Panel Overlay
WS510-FP-ITALIAN
WS510 Italian Front Panel Overlay
WS510-FP-JAPANESE
WS510 Japanese Front Panel Overlay
WS510-FP-KOREAN
WS510 Korean Front Panel Overlay
WS510-FP-RUSSIAN
WS510 Russian Front Panel Overlay
WS510-FP-SPANISH
WS510 Spanish Front Panel Overlay

Mixed Signal Accessories

PK400-0
Extra Large Gripper Probe Set . Includes 22 probes
PK400-1
Large Gripper Probe Set for 0.10 inch (2.54mm) pin pitch. Includes 10 probes with color coded leads
PK400-2
Medium Gripper Probe Set for 0.04 inch (1.0mm) pin pitch. Includes 10 probes with color coded leads
PK400-3
Small Gripper Probe Set for 0.008 inch (0.2 mm) pin pitch. Includes 10 probes with color coded leads
MSO-MICTOR
36 Channel Mictor Connector for MS Series (Includes 1 MSO-MICTOR-SHROUD)
MSO-3M
18 Pin 3M Interface cable MSO-3M (Mates with 3M part number 2520-6002)
MSO-DLS-18
16" Digital Lead Set, D0-D17
MSO-DLS-36
16" Digital Lead Set, D18-D35

Active Voltage Probes

ZS1500-QUADPAK
Set of 4 ZS1500, 1.5 GHz High Impedance Active Probes
ZS1000-QUADPAK
Set of 4 ZS1000, 1 GHz High Impedance Active Probes
ZS1500
1.5 GHz, 0.9 pF, 1 MOhm Active Voltage Probe
ZS1000
1 GHz, 0.9 pF, 1 MOhm Active Voltage Probe

Differential Probes (<= 1.5 GHz)

AP033
500 MHz Differential Probe
ZD200
200 MHz, 3.5 pF, 1 MOhm Active Differential Probe, ±20 V
ZD1000
1 GHz, 1.0 pF Active Differential Probe, ±8 V
ZD1500
1.5 GHz, 1.0 pF Active Differential Probe, ±8 V

Current Probes

DCS015
Deskew Calibration Source for CP031,CP031A, CP030, CP030A and AP015 Limited Availability
CP150
150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 2 meter cable
CP500
500 A, 2 MHz Current Probe - AC/DC, 500 A rms, 700 A Peak Pulse, 6 meter cable
CP030
30A, 50 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP031
30A, 100 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP030A
30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP031A
30A, 100 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP030-3M
30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 3 meter cable
CP150-6M
150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 meter cable
DCS025
Deskew Calibration Source for CP030, CP030A, CP031, CP031A, AP015, CP150, CP500

High Voltage Passive Probes

PPE4KV
100:1 400 MHz 50 MOhms High-Voltage Probe
PPE6KV
1000:1 400 MHz 50 MOhms High-Voltage Probe
HVP120
400 MHz, 1kV Vrms High-Voltage Passive Probe

Passive Probes

PP008-1
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP009-1
500 MHz passive probe, 10: 1 (for WaveSurfer Xs), mechanically identical to PP005A
PP022-1
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP024-1
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm

High Voltage Differential Probes

AP031
700 V, 25 MHz High-Voltage Differential Probe (÷10, ÷100)
ADP300
1kV, 20 MHz High-Voltage Differential Probe
ADP305
1kV, 100 MHz High-Voltage Differential Probe
HVD3102
1kV, 25 MHz High Voltage Differential Probe
HVD3106
1kV, 120 MHz High Voltage Differential Probe
HVD3106-6M
1kV, 80 MHz High Voltage Differential Probe with 6m cable
HVD3605
6kV, 100 MHz High Voltage Differential Probe
HVD3102-NOACC
1kV, 25 MHz High Voltage Differential Probe without tip Accessories
HVD3106-NOACC
1kV, 120 MHz High Voltage Differential Probe without tip Accessories
HVD3206
2kV, 120 MHz High Voltage Differential Probe
HVD3206-6M
2kV, 80 MHz High Voltage Differential Probe with 6m cable

Differential Amplifiers

DA1855A
1 Ch, 100 MHz Differential Amplifier with Precision Voltage Source
DXC100A
÷100 or ÷10 Selectable, 250 MHz Passive Differential Probe Pair
DXC200
÷1, 50 MHz, Passive Differential Probe Pair
DXC-5100
100:1 250 MHz 40 Mohm 2.75pf Differential Probe Pair;
DA101
10:1 1 MOhm Passive Attenuator
DA1855A-PR2
2 Ch, 100 MHz, Differential Amplifier with Precision Voltage Source
DA1855A-PR2-RM
2 Ch, DA1855A with Rackmount (must be ordered at time of purchase, no retrofit)
DA1855A-RM
DA1855A with rackmount;

Probe Parts and Kits

PACC-ZD008
Y-Lead Adapter
PACC-ZD001
Y lead Adapter for ZD differential probes - Qty 1
PACC-ZD002
Solder-in lead for ZD differential probe - QTY 2
PACC-ZD003
Long spring ground for ZD differential probe - QTY 2
PACC-ZD004
Tip saver for ZD differential probe - QTY 2
PACC-ZD005
Swivel tip adapter for ZD differential probe - QTY 1
PACC-ZD006
Small IC adapter for ZD differential probe - QTY 2
PACC-ZD007
Replacement Accessory kit for ZD200
PK111
Replacement Accessory kit for ZD500, ZD1000, and ZD1500

Probe Adapters

TPA10
TekProbe to ProBus Probe Adapter
TPA10-QUADPAK
Set of 4 TPA10 TekProbe to ProBus Probe Adapters. Includes soft carrying case.

High Voltage Fiber Optically-isolated Probes

HVFO103
High Voltage Fiber Optic Probe, 60 MHz Bandwidth. Includes soft-carrying case. Requires attenuating tip (ordered separately). Includes Qty. 1 1m Fiber Optic Cable.
HVFO100-1X-TIP
HVFO103 +/-1V (1x Attenuation) Tip Accessory
HVFO100-5X-TIP
HVFO103 +/-5V (5x Attenuation) Tip Accessory
HVFO100-20X-TIP
HVFO103 +/-20V (20x Attenuation) Tip Accessory
HVFO100-40X-TIP
HVFO103 +/-40V (40x Attenuation) Tip Accessory
HVFO-1M-FIBER
HVFO 1m Fiber Optic Cable Accessory
HVFO-2M-FIBER
HVFO 2m Fiber Optic Cable Accessory
HVFO-6M-FIBER
HVFO 6m Fiber Optic Cable Accessory
ProductPrice*Description 
WaveSurfer 510$10,000.001 GHz, 10 GS/s, 4 Ch, 16 Mpts/Ch DSO with 12.1" Touch Screen Display. 10 GS/s, 32 Mpts InterleavedRequest Quote

* Prices Shown Are US Domestic Prices, MSRP, and are exclusive of local and state taxes, shipping, levies, fees, duties, exportation/importation costs, service and warranties outside the United States, and assume standard 30 day payment terms.

Information and/or pricing may be changed or updated without notice. Teledyne LeCroy may also make improvements and/or changes in the products and/or the programs, as well as associated pricing, described in this information at any time without notice.

Because international information is provided at this Web Site, not all products, programs or pricing mentioned will be available in your country. Please contact your local sales representative for information as to products and services available in your country.