WaveRunner 64MXI-A

600 MHz, 5 GS/s, 4ch, 12.5Mpts/Ch DSO with 10.4" Color Touch Screen Display 10 GS/s, 25 Mpts/Ch interleaved. Includes Advanced Math, Customization Package, Jitter and Timing Analysis, and HDTV Trigger (XMATH, XDEV, JTA2, HDTV-TRIG)


WaveRunner 204MXi-A   (2 GHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Limited Availability
Quick Specs
Nominal Analog Bandwidth @ Ω 50 10 mV-1 V/div2 GHz
Input Channels4
Single-Shot Sample Rate/Ch5 GS/s
Standard Memory12.5M/25M 10,000
WaveRunner 204Xi-A   (2 GHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Limited Availability
Quick Specs
Input Channels4
Single-Shot Sample Rate/Ch5 GS/s on 4 Ch
10 GS/s on 2 Ch
WaveRunner 104MXi-A   (1 GHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
Nominal Analog Bandwidth @ Ω 50 10 mV-1 V/div1 GHz
Input Channels4
Single-Shot Sample Rate/Ch5 GS/s
Standard Memory12.5M/25M 10,000
WaveRunner 104Xi-A   (1 GHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
Input Channels4
Single-Shot Sample Rate/Ch5 GS/s on 4 Ch
10 GS/s on 2 Ch
WaveRunner 64MXI-A   (600 MHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
Nominal Analog Bandwidth @ Ω 50 10 mV-1 V/div600 MHz
Input Channels4
Single-Shot Sample Rate/Ch5 GS/s
Standard Memory12.5M/25M 10,000
WaveRunner 64Xi-A   (600 MHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
Input Channels4
Single-Shot Sample Rate/Ch5 GS/s on 4 Ch
10 GS/s on 2 Ch
WaveRunner 62Xi-A   (600 MHz Bandwidth, 2 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
Input Channels2
Single-Shot Sample Rate/Ch5 GS/s on 2Ch
10 GS/s on 1 Ch
WaveRunner 44MXi-A   (400 MHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
Nominal Analog Bandwidth @ Ω 50 10 mV-1 V/div400 MHz
Input Channels4
Single-Shot Sample Rate/Ch5 GS/s
Standard Memory12.5M/25M 10,000
WaveRunner 44Xi-A   (400 MHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
Input Channels4
Single-Shot Sample Rate/Ch5 GS/s on 4 Ch
Check up to three models.
The Teledyne LeCroy WaveRunner Xi-A is the most powerful and capable scope available in its class. Basic system validation using advanced triggers, fast viewing modes, measurement parameters, or serial decodes is simple and easy. Advanced debug, multi-domain analysis, and waveshape analysis are possible with tools unique to WaveRunner Xi-A. Optional application packages help you make sense of well-defined problems.
Enhanced Understanding of Serial Data Signals

Trigger on I2C, SPI, UART, RS-232, AudioBus (I2S, LJ, RJ, TDM), LIN, CAN, or FlexRay or MIL-STD-1553 serial data patterns. Intuitively decode values on the oscilloscope grid.

Powerful Triggers Isolate Events

An extensive collection of SMART, Serial, and Digital (MS Series) triggers enables users to quickly and easily isolate events of interest (some optional).

WaveStream™ Fast Viewing Mode

Use the high sampling rate and WaveStream fast viewing mode to characterize signal shape, rise time, overshoot, etc., and verify the presence or absence of high-speed transients.

Advanced Acquisition Modes

Sequence Mode allows you to partition your acquisition memory into segments and capture specific events over long periods of time. Then, view and analyze each segment individually.

WaveScan™ Advanced

Search and Analysis WaveScan provides the ability to locate unusual events in a single capture, or scan for an event in many acquisitions over a long period of time using more than 20 different search/scan modes. Use ScanHisto or ScanOverlay to display intuitive scanned results.

Completely Customizable

Quickly create your own measurement parameters or math functions using Excel, MATLAB®, or VBScripts (some capability optional).

Advanced Application Packages

Use a variety of application packages to provide detailed, fast solutions for specific problems.

Fast Long Memory with Front Panel Zoom Controls

WaveRunner Xi-A's long memory is optimized for calculation of more information 10–100x faster than other oscilloscopes, while enabling easy access to simple zooming and positioning from the front panel.

Extensive Math and Measurement Capability

More standard and optional measurements and more powerful math capability are provided with results returned faster than in other oscilloscopes.

Beyond Time Domain Analysis

Amplify your understanding with multidomain analysis of your signals. Convert signal information into Statistical domain (Histogram), Spectral domain (long memory FFTs), Jitter, Modulation, or other Measurement Parameter domains (Tracks of measurement parameters). (Some capability is optional.)

Integrated Tool Sets

Teledyne LeCroy math, measure, and analysis tools are tightly integrated with basic scope operations. It's easy to link capabilities and expand understanding. Free yourself from constraints!

Complete Probing Solutions

A wide variety of active FET probes, current probes, differential probes, HV probes, etc. with complete tip and ground accessories make it easy to probe your signals.

Mixed Signal Oscilloscope Option

The MS Series can capture digital signals with speeds up to 500 MHz. View up to 36 digital channels with up to 50 Mpts/Ch memory and analyze analog and digital events together.

Power/Amplifier Measurements

Excellent overdrive recovery and signal integrity make WaveRunner Xi-A ideal for high-voltage switching loss, conduction loss, ripple, switching power supply, and other amplifier measurements. Use with Teledyne LeCroy Differential Amplifiers for highperformance 100,000:1 Common Mode Rejection Ratio.

Timing Characterization

Extensive triggers allow fast event isolation. Measure timing statistically and view behavior graphically using histograms. Gain real understanding of root cause.

Slow/High-speed Signal Mix

Long memory, HFREJ trigger coupling, built-in noise filtering, etc. enable fast understanding of signal behavior in circuits with a mix of slow-speed (sensor, actuator, power supply, mechanical) and high-speed signals.

Vertical System

Nominal Analog Bandwidth @ Ω 50 10 mV-1 V/div 600 MHz
Rise Time (typical) 500 ps
Input Channels 4
Bandwidth Limiters 20 MHz; 200 MHz
Input Impedance 1 MΩ || 16 pF or 50 Ω
Input Coupling 50 Ω: DC, 1 MΩ: AC, DC, GND
Maximum Input Voltage 50 Ω: 5 Vrms, 1 MΩ: 400 V max. (DC + Peak AC = 5 kHz)
Input Connector ProBus/BNC
Vertical Resolution 8 bits; up to 11 with enhanced resolution (ERES)
Sensitivity 50 Ω: 2 mV/div–1 V/div fully variable; 1 MΩ: 2 mV–10 V/div fully variable
Offset Range 50 Ω: ±1 V @ 2–98 mV/div, ±10 V @ 100 mV/div–1 V/div; 50 Ω: 1 M Ω: ±1 V @ 2–98 mV/div, ±10 V @ 100 mV/div–1 V/div, ±100 V @ 1.02 V/div–10 V/div
 

Main Specifications

Probes One PP008 per channel standard; Optional passive and active probes available.
 

Timebase System

Roll Mode User selectable at <= 500 ms/div and <= 100 kS/s
 

Horizontal System

Timebases Internal timebase common to all input channels; an external clock may be applied at the auxiliary input
Time/Division Range Real time: 200 ps/div–10 s/div, RIS mode: 200 ps/div to 10 ns/div, Roll mode: up to 1,000 s/div
Clock Accuracy <= 5 ppm @ 25 °C (typical) (<= 10 ppm @ 5–40 °C)
Trigger and Interpolator Jitter Jitter <=3 ps rms (typical)
Sample Rate and Delay Time Accuracy Equal to Clock Accuracy
Channel-Channel Deskew Range ±9 x time/div setting, 100 ms max., each channel
External Clock DC to 600 MHz; (DC to 1 GHz for 104Xi and 204Xi) 50 Ω, (limited BW in 1 MΩ), BNC input, limited to 2 Ch operation (1 Ch in 62Xi-A), (minimum rise time and amplitude requirements apply at low frequencies)
 

Acquisition System

Single-Shot Sample Rate/Ch 5 GS/s
Interleaved Sample Rate (2 Ch) 10 GS/s
Random Interleaved Sampling (RIS) 200 GS/s
RIS Mode User selectable from 200 ps/div to 10 ns/div
Maximum Trigger Rate 1,250,000 waveforms/second
Acquisition Memory Options Max. Acquisition Points (4 Ch/2 Ch, 2 Ch/1 Ch in 62Xi-A) Segments (Sequence Mode)
Sequence Time Stamp Resolution 1 ns
Standard Memory 12.5M/25M 10,000
 

Acquisition Processing

Averaging Summed and continuous averaging to 1 million sweeps
Enhanced Resolution (ERES) From 8.5 to 11 bits vertical resolution
Envelope (Extrema) Envelope, floor, or roof for up to 1 million sweeps
Interpolation Linear or (Sinx)/x
Time Resolution (min, Single-shot) 100 ps (10 GS/s)
 

Triggering System

Trigger Modes Normal, Auto, Single, Stop
Sources Any input channel, External, Ext/10, or Line; slope and level unique to each source, except Line
Coupling DC, AC (typically 7.5 Hz), HF Reject, LF Reject
Pre-trigger Delay 0–100% of memory size (adjustable in 1% increments, or 100 ns)
Post-trigger Delay Up to 10,000 divisions in real time mode, limited at slower time/div settings in roll mode
Hold-off by Time or Events 1 ns to 20 s or 1 to 1,000,000,000 events
Internal Trigger Range ±4.1 div from center (typical)
Trigger Sensitivity with Edge Trigger (Ch 1–4) 2 div @ < 600 MHz 1 div @ < 200 MHz
External Trigger Input Range EXT/10 ±4 V; EXT ±400 mV
Max. Trigger Frequency, SMART Trigger 600 MHz @ = 10 mV
Minimum Time Between Sequential Segments Sequential Segments 800 ns
 

Basic Triggers

Edge Triggers when signal meets slope (positive, negative, or Window) and level condition.
TV-Composite Video Triggers selectable fields (1, 2, 4, or 8), Positive or Negative slope, or Line (up to 1500), for NTSC, PAL, SECAM, or non-standard video (up to 1500 lines).
 

SMART Triggers

State or Edge Qualified Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events.
Dropout Triggers if signal drops out for longer than selected time between 1 ns and 20 s.
Pattern Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input – 2 Ch+EXT on WaveRunner 62Xi-A). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pa
 

SMART Triggers with Exclusion Technology

Glitch and Pulse Width Triggers on positive or negative glitches with widths selectable from 500 ps to 20 s or on intermittent faults (subject to bandwidth limit of oscilloscope).
Signal or Pattern Interval Triggers on intervals selectable between 1 ns and 20 s.
Timeout (State/Edge Qualified) Triggers on any source if a given state (or transition edge) has occurred on another source. Delay between sources is 1 ns to 20 s, or 1 to 99,999,999 events.
Runt Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 s.
Slew Rate Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 s.
Exclusion Triggering Trigger on intermittent faults by specifying the normal width or period.
 

Color Waveform Display

Type Color 10.4" flat-panel TFT-LCD with high resolution touch screen
Resolution SVGA; 800 x 600 pixels; maximum external monitor output resolution of 2048 x 1536 pixels
Number of traces Display a maximum of 8 traces. Simultaneously display channel, zoom, memory, and math traces.
Grid Styles Auto, Single, Dual, Quad, Octal, XY, Single + XY, Dual + XY
Waveform Representation Sample dots joined or dots only in real-time mode
 

Internal Waveform Memory

Internal Waveform Memory M1, M2, M3, M4 Internal Waveform Memory (store full-length waveform with 16 bits/data point) or store to any number of files limited only by data storage media.
 

LeCroy WaveStream™ Fast Viewing Mode

Intensity 256 Intensity Levels, 1–100% adjustable via front panel control
Number of Channels up to 4 simultaneously
Max Sampling Rate 5 GS/s (10 GS/s for WaveRunner 62Xi-A, 64Xi-A, 104Xi-A, 204Xi-A in interleaved mode)
Waveforms up to 8000 waveforms/second
Operation Front panel toggle between normal real-time mode and LeCroy WaveStream Fast Viewing mode
 

Automatic Setup

Auto Setup Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals.
Vertical Find Scale Automatically sets the vertical sensitivity and offset for the selected channels to display a waveform with maximum dynamic range.
 

Probes

Probe System: ProBus Automatically detects and supports a variety of compatible probes.
Scale Factors Automatically or manually selected, depending on probe used
 

Setup and Waveform Storage

Front Panel and Instrument Status Store to the internal hard drive, over the network, or to a USB-connected peripheral device.
 

Zoom Expansion Traces

Zoom Expansion Traces Display up to 4 Zoom/Math traces with 16 bits/data point
 

Interface

Remote Control Via Windows Automation, or via LeCroy Remote Command Set
GPIB Port (optional) Supports IEEE – 488.2
Ethernet Port 10/100/1000Base-T Ethernet interface (RJ-45 connector)
USB (Host) 5 USB 2.0 ports (one on front of instrument) supports Windows-compatible devices.
External Monitor Port Standard 15-pin D-Type SVGA-compatible DB-15; connect a second monitor to use extended desktop display mode with XGA resolution.
Serial Port DB-9 RS-232 port (not for remote oscilloscope control)
 

Auxiliary Input

Signal Types Selected from External Trigger or External Clock input on front panel
Coupling 50 Ω: DC, 1 MΩ: AC, DC, GND
Maximum Input Voltage 50 Ω: 5 Vrms, 1 MΩ: 400 V max. (DC + Peak AC = 5 kHz)
 

Auxiliary Output

Signal Types Trigger Enabled, Trigger Output. Pass/Fail, or Off
Output Signal TTL, ˜3.3 V
Calibrator Signal Output available on front panel connector provides a variety of signals for probe calibration and compensation.
 

General

Auto Calibration Ensures specified DC and timing accuracy is maintained for 1 year minimum.
Power Requirements 90–264 Vrms at 50/60 Hz; 115 Vrms (±10%) at 400 Hz, Automatic AC Voltage Selection Installation Category: 300V CAT II; Max. Power Consumption: 340 VA/340 W; 290 VA/290 W for WaveRunner 62Xi-A
 

Environmental and Safety

Temperature (Operating) +5 °C to +40 °C
Temperature (Non-Operating) -20 °C to +60 °C
Humidity (Operating) Maximum relative humidity 80% for temperatures up to 31 °C decreasing linearly to 50% relative humidity at 40 °C
Humidity (Non-Operating) 5% to 95% RH (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating) Operating Up to 2,000 m
Altitude (Non-Operating) Non-Operating 12,190 m
 

Physical Dimensions

Dimensions (HWD) 260 mm x 340 mm x 152 mm Excluding accessories and projections (10.25" x 13.4" x 6")
Net Weight 6.95 kg. (15.5 lbs.)
 

Certifications

Certifications CE Compliant, UL and cUL listed; Conforms to EN 61326, EN 61010-1, UL 61010-1 2nd Edition, and CSA C22.2 No. 61010-1-04.
 

Warranty and Service

Warranty and Service 3-year warranty; calibration recommended annually. Optional service programs include extended warranty, upgrades, calibration, and customization services.
 

Serial Data Compliance

QPHY-MOST50e
QualiPHY Enabled MOST50 ePHY Compliance Software Option. Requires options DFP2 and SDM or SDA2
QPHY-BroadR-Reach
QualiPHY Enabled BroadR-Reach Compliance Software Option. Requires either SDA2 or JTA2
QPHY-ENET
QualiPHY Enabled Ethernet 10/100/1000BT Compliance Software Option
QPHY-USB
QualiPHY Enabled USB 2.0 Compliance Software Option
ENET-2ADA-BNCSMA
Adapter Set- 2 BNC/M to SMA/F
ENET-2CAB-SMA018
Cable Set- 2 SMA-SMA 18 inches
ENET-2CAB-SMA036
Cable Set- 2 SMA-SMA 36 inches
ET-PMT
Electrical Telecom Pulse Mask Software;
WRXi-SDM
Serial Data Mask Software Package for WaveRunner Xi Series

Serial Trigger and Decode

WRXi-USB2-HSICbus D
USB 2.0 HSIC Decode Option
CANbus TD
CANbus TD Trigger and Decode Option
CANbus TDM
CAN Bus Trigger, Decode, and Measure/Graph option
WRXi-DigRFV4bus D
DigRF V4 Bus Decode option for WaveRunner Xi series
CANbus TD 5LIC
CAN Bus Trigger and Decoding Package with License to work on 5 oscilloscopes
WRXi-NRZbus D
NRZ Bus Decode Option for WaveRunner Xi
WRXi-Manchesterbus D
Manchester Bus Decode Option for WaveRunner Xi
WRXi-ENETbus D
ENET Bus Decode Option for WaveRunner Xi
CANbus TDM-5LIC
CAN Bus Trigger, Decode, and Measure/Graph option with 1 Hardware Kit and 5 SW Licenses
TC1041-OPTO
CAN 1041 Opto-isolated High-speed Trigger Coupler
TC1050-OPTO
CAN 1050 Opto-isolated High-speed Trigger Coupler
TC1054-OPTO
CAN 1054 Opto-isolated Low-speed Trigger Coupler
TC251-OPTO
CAN 251 Opto-isolated High-speed Trigger Coupler (one is included with CANbus TD)
TC5790c-OPTO
CAN 5790c Opto-isolated Single-wire Trigger Coupler
TC10011-OPTO
CAN B10011S Opto-isolated Truck and Bus Trigger Coupler
WRXi-MSO-EMB
Embedded bundle, Includes MS-500-36 with I2C TD, SPI TD, UART TD
WRXI-EMB
Embedded bundle, Includes I2C TD, SPI TD, UART TD
WRXi-1553 TD
MIL-STD-1553 Trigger and decode option for WaveRunner Xi
WRXi-ARINC429bus DSymbolic
ARINC 429 Bus Symbolic Decode option for WaveRunner Xi/Xi-A
WRXi-AudioBus TD
AudioBus trigger and decode for WaveRunner Xi
WRXi-AudioBus TDG
AudioBus trigger, decode, and graph for WaveRunner Xi
WRXi-CANbus TD
CAN Bus Trigger and Decode Option
WRXi-CANbus TDM
CAN Bus Trigger Decode and Measure/Graph Option
WRXi-DigRF3Gbus D
DigRF 3G Bus Decode option for WaveRunner Xi/Xi-A
WRXi-DPHYbus D
D-PHY Bus Decode option for WaveRuner Xi/Xi-A
WRXI-FLEXRAYBUS TD
FlexRay Trigger and Decode Option
WRXi-FlexRaybus TDP
FlexRay Trigger, Decode and Physical Layer Test Option
WRXI-I2CBUS TD
I2C Bus Trigger & Decode Option for WaveRunner Xi Oscilloscopes
WRXI-LINBUS TD
LIN Bus Trigger & Decode Option for WaveRunner Xi Series Oscilloscopes
WRXi-PROTObus MAG
Serial Debug Toolkit - Measure Analyze Graph for WaveRunner Xi/Xi-ACompatible with I2C, SPI, UART, CAN, LIN, FLX, D-PHY, DigRF 3G, DigRF v4, ARINC 429, MIL-STD-1553
WRXi-ProtoSync
Decode Annotation and Protocol Analyzer Software Synchronization Option for WaveRunner Xi/Xi-ACompatible with USB2bus D, SATAbus D, SASbus D, FCbus D
WRXi-SATAbus D
SATA Decode option for WaveRunner Xi/Xi-ASupports SATA Gen 1, 2, and 3.
WRXI-SPIBUS TD
SPI Bus Trigger & Decode Option for WaveRunner Xi Oscilloscopes
WRXi-UART-RS232BUS TD
UART and RS232 Bus Trigger and Decode Option for WaveRunner Xi Oscilloscopes
WRXi-USB2bus D
USB 2.0 Bus Decode option for WaveRunner Xi/Xi-A
WRXI-SENTbus D
SENT Bus Decode Option for WaveRunner Xi

Jitter Analysis Software

WRXi-JITKIT
Clock, clock-data Jitter Analysis and views of time, statistical, spectral, and jitter overlay

Miscellaneous

WRXi-SOFTCASE
WRXi Soft Carrying Case
WRXi-HARDCASE
WRXi Hard Carrying Case
WRXi-KYBD
WRXi Keyboard Accessory
WRXi-RACK
WRXi Rack Mount Accessory Kit
WRXi-MS-CLAMP
WRXi Clamp Mounting Stand
WRXi-A-FP-GERMAN
WRXi-A German Front Panel Overlay
WRXi-A-FP-FRENCH
WRXi-A French Front Panel Overlay
WRXi-A-FP-ITALIAN
WRXi-A Italian Front Panel Overlay
WRXi-A-FP-SPANISH
WRXi-A Spanish Front Panel Overlay
WRXi-A-FP-JAPANESE
WRXi-A Japanese Front Panel Overlay
WRXi-A-FP-KOREAN
WRXi-A Korean Front Panel Overlay
WRXi-A-FP-CHNES-TR
WRXi-A Chinese (Traditional) Front Panel Overlay
WRXi-A-FP-CHNES-SI
WRXi-A Chinese (Simplified) Front Panel Overlay
WRXi-A-FP-RUSSIAN
WRXi-A Russian Front Panel Overlay

Other Software Options

WRXi-SPECTRUM
Spectrum Analyzer and Advanced FFT Option for WaveRunner Xi Series
WRXi-EMC
EMC Pulse Parameter Package
WRXi-STAT
Histogram and Statistical Analysis Pkg.
WRXi-XDEV
Advanced Customization Software Package for WaveRunner Xi Series

Data Storage Software

WRXi-AORM
Advanced Options Record Measurement Package
WRXi-DDM2
Disk Drive Measurement Software Package for WaveRunner Xi Series

Remote Control/Network Options

USB2-GPIB
External USB 2.0 to GPIB IEEE 488.2 adapter

Power Analysis Software

WRXi-PWR
Power Analysis Option for WR Xi

Digital Filtering Software

WRXi-DFP2
Digital Filter Software Package for WaveRunner Xi Series

Mixed Signal Solutions

MS-500
500 MHz, 18 Channels, 2 GS/s, 50 Mpts/ch Mixed Signal Oscilloscope Option
MS-500-36
250 MHz,36 Ch,1 GS/s,25 Mpts/ch (500MHz,18 Ch,2 GS/s,50 Mpts/ch Interleaved) Mixed Signal Option
MS-250
250 MHz, 18 Channels, 1 GS/s, 10 Mpts/ch Mixed Signal Oscilloscope Option

Mixed Signal Accessories

PK400-1
Large Gripper Probe Set for 0.10 inch (2.54mm) pin pitch. Includes 10 probes with color coded leads
PK400-2
Medium Gripper Probe Set for 0.04 inch (1.0mm) pin pitch. Includes 10 probes with color coded leads
PK400-3
Small Gripper Probe Set for 0.008 inch (0.2 mm) pin pitch. Includes 10 probes with color coded leads
MSO-MICTOR
36 Channel Mictor Connector for MS Series (Includes 1 MSO-MICTOR-SHROUD)
MSO-3M
18 Pin 3M Interface cable MSO-3M (Mates with 3M part number 2520-6002)
MSO-DLS-36
16" Digital Lead Set, D18-D35
MSO-MICTOR-SHROUD
Shroud for MSO-MICTOR connector, Kit of 3

Serial Data Test Fixtures

TF-ENET-B
10/100/1000BaseT Ethernet Test Fixture
TF-USB-B
USB 2.0 Compliance Test Fixture

Differential Probes (3-6 GHz)

D300A-AT
WaveLink D300 3 GHz/4.8Vp-p Differential Amplifier Module with Adjustable Tips.

Active Voltage Probes

HFP1000
1 GHz, 0.7pF Active Voltage Probe(10:1), Small Form Factor
HFP1500
1.5 GHz, 0.7pF Active Voltage Probe(10:1), Small Form Factor
HFP2500
2.5 GHz, 0.7pF Active Voltage Probe(10:1), Small Form Factor
ZS1500-QUADPAK
Set of 4 ZS1500, 1.5 GHz High Impedance Active Probes
ZS1000-QUADPAK
Set of 4 ZS1000, 1 GHz High Impedance Active Probes
ZS1500
1.5 GHz, .9 pF, 1 MOhm Active Voltage Probe
ZS1000
1 GHz, .9 pF, 1 MOhm Active Voltage Probe
ZS2500
2.5 GHz, .9 pF, 1 MOhm Active Voltage Probe
ZS2500-QUADPAK
Set of 4 ZS2500, 2.5 GHz High Impedance Active Probes

Differential Probes (<= 1.5 GHz)

AP033
500 MHz Differential Probe
AP034
1 GHz, Active Differential Probe (÷1, ÷10, ÷20)
ZD200
200 MHz, 3.5 pF, 1 MOhm Active Differential Probe, ±20 V
ZD500
500 MHz, 1.0 pF Active Differential Probe, ±8 V
ZD1000
1 GHz, 1.0 pF Active Differential Probe, ±8 V
ZD1500
1.5 GHz, 1.0 pF Active Differential Probe, ±8 V

Current Probes

AP015
30 A, 50 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse
DCS015
Deskew Calibration Source for AP015
CP150
150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse
CP500
500 A, 2 MHz Current Probe - AC/DC, 500 A rms, 700 A Peak Pulse
CP030
30A, 50MHz Current Probe
CP031
30A, 100MHz Current Probe

High Voltage Probes

PPE1.2KV
10:1/100:1 200/300 MHz 50 MOhms High-Voltage Probe 600V/1.2kV Max. Volt. DC
PPE20KV
1000:1 100 MHz 100 MOhms High-Voltage Probe 20kV Max. Volt. DC + 40kVPeak AC
PPE2KV
100:1 400 MHz 50 MOhms High-Voltage Probe
PPE4KV
100:1 400 MHz 50 MOhms High-Voltage Probe
PPE5KV
100:1 400 MHz 50 MOhms High-Voltage Probe
PPE6KV
1000:1 400 MHz 5 MOhms/50 MOhms High-Voltage Probe

High Voltage Differential Probes

AP031
700 V, 15 MHz High-Voltage Differential Probe (÷10, ÷100)
ADP300
1,400 V, 20 MHz High-Voltage Differential Probe
ADP305
1,400 V, 100 MHz High-Voltage Differential Probe

Transmission Line Probes

PP065
100:1 1 GHz 5 KOhms Passive Probe

Optical Probes

OE425
Optical-to-Electrical Converter, 500-870 nm ProBus BNC Connector
OE455
Optical-to-Electrical Converter, 950-1630 nm ProBus BNC Connector

Differential Amplifiers

DA1855A
1 Ch, 100 MHz Differential Amplifier with Precision Voltage Source
DXC100A
÷100 or ÷10 Selectable, 250 MHz Passive Differential Probe Pair
DXC200
÷1, 50 MHz, Passive Differential Probe Pair
DXC-5100
100:1 250 MHz 10 Mohm 2.75pf Differential Probe Pair;
DA101
10:1 1 MOhm Passive Attenuator
DA1855A-PR2
2 Ch, 100 MHz, Differential Amplifier with Precision Voltage Source
DA1855A-PR2-RM
2 Ch, DA1855A with Rackmount (must be ordered at time of purchase, no retrofit)
DA1855A-RM
DA1855A with rackmount;

Probe Parts and Kits

Dxx0-Cable-HiTemp
Replacement 30" matched cable set for use with HiTemp Solder tip leadset
PACC-ZD001
Y lead Adapter for ZD differential probesQty 1
PACC-ZD002
Solder-in lead for ZD differential probeQty 2
PACC-ZD003
Long spring ground for ZD differential probeQty 2
PACC-ZD004
Tip saver for ZD differential probeQty 2
PACC-ZD005
Swivel tip adapter for ZD differential probeQty 1
PACC-ZD006
Small IC adapter for ZD differential probeQty 2
PK111