1kV, 25 MHz High Voltage Differential Probe without tip Accessories


    High Voltage Differential Probes


HVD3102 - 1kV, 25 MHz High Voltage Differential Probe
HVD3102-NOACC - 1kV, 25 MHz High Voltage Differential Probe without tip Accessories
HVD3106 - 1kV, 120 MHz High Voltage Differential Probe
HVD3106-NOACC - 1kV, 120 MHz High Voltage Differential Probe without tip Accessories
HVD3106-6M - 1kV, 80 MHz High Voltage Differential Probe with 6m cable
HVD3206 - 2kV, 120 MHz High Voltage Differential Probe
HVD3206-6M - 2kV, 80 MHz High Voltage Differential Probe with 6m cable
HVD3605 - 6kV, 100 MHz High Voltage Differential Probe
AP031 - 700 V, 25 MHz High-Voltage Differential Probe (÷10, ÷100)
ADP300 - 1kV, 20 MHz High-Voltage Differential Probe
ADP305 - 1kV, 100 MHz High-Voltage Differential Probe

Teledyne LeCroy high voltage differential probes provide high CMRR over a broad frequency range to simplify the measurement challenges found in noisy, high common-mode power electronics environments.The probe’s design is easy-to-use and enables safe, precise high voltage floating measurements.

The HVD3000 series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV class electricalapparatus. The table below provides a list of recommended probe models based on specific device under test applications.

Device Under TestRecommended ModelSafety ClassBandwidthCable LengthTip Accessories Included
120 V/240 V Half-Bridge Circuit TopologiesHVD31021 kV25 MHz2 mYes
HVD3102-NOACC1 kV25 MHz2 mNo
HVD31061 kV120 MHz2 mYes
HVD3106-NOACC1 kV120 MHz2 mNo
380 V - 600 V Class Electrical ApparatusHVD31061 kV120 MHz2 mYes
HVD3106-NOACC1 kV120 MHz2 mNo
HVD3106-6M1 kV80 MHz6 mYes
Solar PV InverterHVD31061 kV120 MHz2 mYes
HVD32062 kV120 MHz2 mYes
HVD3206-6M2 kV80 MHz6 mYes
5 kV Electrical ApparatusHVD36058.485 kV100 MHz6 mYes
Key Features
  • 1 kV CAT safety rated
  • Exceptional common-mode rejection ratio (CMRR) across a broad frequency range
  • 1% gain accuracy
  • High offset capability at both high and low attenuation
  • AC or DC coupling
  • ProBus active probe interface with automatic scaling
  • Auto-zero capabilities
  • Wide oscilloscope compatibility
Widest Application Coverage

The HVD310x high voltage differential probe covers a wide range of applications, from 120/240 V switch-mode power supplies through 600 V class electrical apparatus. It is the only 1 kV safety rated probe that serves the full 600 V class requirement.

Exceptional Common-Mode Rejection Ratio

The CMRR for the probes is exceptional out to very high frequencies, greatly improving measurement capability in noisy, high common-mode environments found in power electronics. The high CMRR combined with low probe noise and high offset capability makes the probes capable of measuring very small control signals floating on high common-mode voltages.

High Precision Measurements

HVD probes provide 1% gain accuracy enabling precise voltage measurements. AutoZero capability ensures further measurement precision by allowing small offset drifts to be calibrated out of the measurement.

Complete Probe Integration

The ProBus interface provides power and communication to the probe eliminating the need for a separate power supply or batteries. Attenuation is automatically selected based on oscilloscope gain range (V/div) setting.

Main Specifications

Bandwidth 25 MHz
Input Coupling DC only
Input Impedance 10 MΩ || 2.5 pF (between inputs)
5 MΩ || 5.0 pF (either input to ground)
Attenuation 100x / 1000x
Rise Time
(10-90%)
14 ns
Differential Voltage Range (High Attenuation) 1500 V (DC + peak AC) from 7 to 500 V/div with up to 1500V offset.
2000 V maximum typical measurable differential voltage before saturation
Differential Voltage Range (Low Attenuation) 27.6 V (DC + peak AC) from 100 mV/div to 6.9 V/div with up to 150V offset.
Common Mode Voltage Range ±1500 V (DC + peak AC), 1000 Vrms (CAT III) (either input to ground)
Maximum Input Voltage to Earth ±2000 Vpk (nominal, either input to ground)
Max Safe Input 1000 Vrms CAT III
per IEC/EN 61010-031/A1:2008
Sensitivity 100 mV/div to 6.9V/div (100X)
7V/div to 500V/div (1000X)
Gain Accuracy 1% (LF, guaranteed)
Slew Rate 100 V/ns (maximum)
Output Coupling AC or DC coupling
Output Termination 1 MΩ
Interface ProBus
Input Lead Length 40 cm input lead length
Cable Length (input lead to oscilloscope connection) 2.25 m
 

Noise and Rejection

CMRR (Typical) DC - 60 Hz: 85 dB
1 MHz: 65 dB
5 MHz: 40 dB
20 MHz: 30 dB
Noise (Probe) 100X: <15 mVrms
1000X: <85mVrms
(referred to input)
 

Environmental and Safety

Temperature (Operating) 0°C to 50°C
Temperature (Non-Operating) -40°C to 70°C
Humidity (Operating) 5% to 80% RH (Non-Condensing) up to 30°C, decreasing linearly to 45% RH at 50°C
Humidity (Non-Operating) 5% to 95% RH (Non-Condensing), 75% RH above 30°C, 45% RH above 40°C
Altitude (Operating) 3,000 m maximum
When used with clip accessories, 2000 m maximum
Altitude (Non-Operating) 10,000 m
Pollution Degree 2, Indoor use only
 
WaveSurfer 10 Oscilloscope

WaveSurfer 10
  Learn More
WaveSurfer 510 Oscilloscope

WaveSurfer 510
  Learn More
HDO4000A High Definition Oscilloscopes


  Learn More
WaveRunner 8000 Oscilloscopes


  Learn More
HDO6000A High Definition Oscilloscopes


  Learn More
HDO8000A High Definition Oscilloscopes


  Learn More
MDA800A Motor Drive Analyzers


  Learn More
WaveMaster / SDA / DDA 8 Zi-B Oscilloscopes


  Learn More