Key Features
- Completely configurable UART-byte structure
- Customizable Message Frame (multiple bytes in one Frame) for proprietary protocol triggering
- Supports 9-bit "address" or "wakeup" mode in byte definition (triggering and decoding)
- Supports up to 16-bit Data words for decoding
- Binary, Hexadecimal, ASCII or Decimal decoding
- Polarity either IdleLow or IdleHigh
- Use analog or digital (MSO) inputs for acquisition and triggering
- Intuitive, color-coded decode overlays
- Interactive protocol table with zoom and pattern search
9-bit "Address" or "Wakeup" Triggering ("T")
Most UART triggers assume a maximum of 8 data bits (excluding stop/start and parity bits) in a single byte. However, our solution supports 9-bit data bytes for situations in which a UART protocol is utilized for Address, Wakeup or other communication to another peripheral, preceding the normal serial data byte transmission.
Interframe Message Time Setup for Proprietary UART-based Protocols ("T" and "D")
UART byte-based serial data signals with proprietary formats are often used. Given the flexibility of the setup of our trigger and decoder, it is often possible to use the Interframe Message Time Setup to "packetize" consecutive bytes into one Message Frame, and then trigger on in serial data in a particular byte location in the complete multi-byte Frame. Then, the UART decoder may be used to decode information as a complete Frame instead of individual Bytes.
Conditional DATA Trigger Setup ("T")
The trigger permits a conditional (<. <=, =, >, >=, <>, inside a range, outside a range) setup for the DATA condition. This is especially useful in situations where abnormal events should be monitored.
Intuitive, Color-coded Decode Overlays ("D")
A transparent overlay with color-coding for specific portions of each protocol and the entire message frame makes it easy to understand your serial data information. Unlike other solutions, with protocol decode information away from the signal, our solution correlates the waveform and the protocol decode directly on the display. As the acquisition length is expanded or shortened, the decode overlay will adjust to show you just the right amount of information.
Interactive Table Summarizes Results ("D")
Turn the oscilloscope into a protocol analyzer with a tabular display of decoded information. Customize the table to show only the data of interest and touch a message in the table to automatically zoom to it and display it on the screen. Export the table for offline analysis. Up to four different decoded signals of any type may be simultaneously displayed in the table.