Key Features
-
Supports SENT and SENT SPC
-
Decodes Frames as Nibbles or Words
-
Supports Fast and Slow Channel Decode and Analysis
-
Extract and plot embedded SENT data
-
SAE Compliance Test Support
-
Intuitive, color-coded decode overlays
-
Interactive protocol table with zoom and pattern search
Comprehensive and Powerful SENT Trigger ("T")
Capability is provided to permit triggering on any Slow or Fast channel ID/Status and Data field, as well as the Start of Message and Error Conditions (Successive Calibration Pulse Error, Pulse Period Error, Slow/Fast Channel CRC Error)
Conditional DATA Trigger Setup ("T")
The trigger permits a conditional (<. <=, =, >, >=, <>, inside a range, outside a range) setup for the DATA condition. This is especially useful in situations where abnormal events should be monitored, such as when a CAN node broadcasts a low or high engine RPM or coolant pressure.
Intuitive, color-coded Decode Overlays ("D")
A transparent overlay with color-coding for specific portions of each protocol and the entire message frame makes it easy to understand your serial data information. Unlike other solutions, with protocol decode information away from the signal, our solution correlates the waveform and the protocol decode directly on the display. As the acquisition length is expanded or shortened, the decode overlay will adjust to show you just the right amount of information.
Interactive Table Summarizes Results ("D")
Turn the oscilloscope into a protocol analyzer with a tabular display of decoded information. Customize the table to show only the data of interest and touch a message in the table to automatically zoom to it and display it on the screen. Export the table for offline analysis. Up to four different decoded signals of any type may be simultaneously displayed in the table.