Key Features
-
Automated and easy-to-use solution for IEEE802.3-2008 10GBASE-T compliance testing
-
Complete physical layer test package including the required test fixture and cables
-
Supports all PMA Transmitter Tests
-
Supports MDI Return Loss Test with Teledyne LeCroy SPARQ Network Analyzer
Complete Electrical Compliance Test
QPHY-10GBASE-T performs all PMA transmitter tests in IEEE802.3-2008 using WaveMaster 8 Zi or LabMaster series oscilloscopes, as well as the MDI return loss test using the SPARQ Network Analyzer. The TF-10GBASE-T fixture kit breaks out the signal pairs to SMAs for connection to the instrument.
Automated Compliance Testing
QPHY-10GBASE-T uses the QualiPHY automated compliance test software to operate the oscilloscope and network analyzer. The QualiPHY test script provides connection diagrams and ensures the proper setup. QualiPHY automates the instrument, and provides a comprehensive report of the results including screenshots.
Advanced Debug Capability
If a compliance failure is found, a variety of packages can help find the root cause quickly and easily. The SDA Expert serial data analysis package has the ability to perform eye, jitter and noise measurements on 4 lanes simultaneously, and is fully integrated into the oscilloscope application software.
Comprehensive and Easy-to-read Test Reports
Measurement results often need to be summarized and tabulated to quickly verify specifications. This information, together with instrument and signal acquisition/test condition setups, results in a fully documented record. QPHY-10GBase-T streamlines this process by incorporating an automatic HTML report generation engine. The created test reports contain tabulated numerical values for each individual test result, including PASS/FAIL and specification limit columns. Reports can also be saved as PDF, HTML or XML.
Complete Test Fixture
TF-NBASE-T supports both NBase-T and 10GBase-T testing. It breaks out the A, B, C and
D pairs from the Ethernet cable to SMA connectors. The kit includes power splitter (2) for adding
the disturbing signal (for 2.5GBase-T), 50 Ohm terminators (6), Ethernet cables (2), SMA/SMA
cables (2) and SMA/BNC cables (4) needed for testing.
List of Tests
QPHY-10GBASE-T includes the following tests:
-
Transmitter Max Output Droop
-
Transmitter Linearity
-
Transmitter Timing Jitter, Master and Slave
-
Transmitter Clock Frequency
-
Transmitter Power Spectral Density
-
Transmitter Power Level
-
MDI Return Loss Test
-
Part Numbers and Descriptions – Probes and Amplifiers