Vertical - Analog Channels |
Analog Bandwidth (Max) | 36 GHz |
Bandwidth | 36 GHz |
Analog Bandwidth @ 50 Ω (-3 dB) (ProAxial/2.92mm Inputs) | 36 GHz (≥5 mV/div) |
Rise Time (10-90%, 50 Ω) | 10.7 ps (test limit, flatness mode) |
Rise Time (20-80%, 50 Ω) | 8.0 ps (flatness mode) |
Input Channels | Up to 80, depending on configuration selected. (Any combination of up to 80 2.92mm input channels) |
Input Channels | Up to 80 @ 36 GHz |
Vertical Resolution | 8-bits |
Vertical Resolution | 8 bits; up to 11 bits with enhanced resolution (ERES) |
Sensitivity | 50 Ω (2.92mm): 5 mV-500mV/div, fully variable (5-9.9 mV/div via zoom) |
DC Vertical Gain Accuracy (Gain Component of DC Accuracy) | ±1% F.S. (typical), offset at 0V; ±1.5% F.S. (test limit), offset at 0V |
Channel-Channel Isolation | DC to 36 GHz: 60 dB (>1000:1) (For any two 2.92mm input channels, same or different v/div settings, typical) |
Offset Range | 50 Ω: ±500 mV @ 5-75 mV/div ±4 V @ 76 mV/div -500mV/div |
DC Vertical Offset Accuracy | ±(1.5% of offset setting + 1.5% F.S. + 1 mV) (test limit) |
Maximum Input Voltage | 2.92 mm Inputs: ±2 Vmax@<76mV/div, 5.5Vrms@≥76mV/div |
Input Coupling | 2.92 mm Inputs: 50 Ω: DC, GND |
Input Impedance | 2.92mm Inputs: 50 Ω+/-2% |
Bandwidth Limiters | 1, 3, 4, 6, 8, 13, 16, 20, 25, 30, 33 GHz |
Rescaling | Length: meters, inches, feet, yards, miles; Mass: grams, slugs; Temperature: celsius, fahrenheit, kelvin; Angle: radian, arcdegr, arcmin, arcsec, cycles, revolutions, turns; Velocity: m/s, in/s, ft/s, yd/s, miles/s; Acceleration: m/s2, in/s2, ft/s2, g0; Volume: liters, cubic meters, cubic inches, cubic feet, cubic yards; Force (Weight): newton, grain, ounce, pound; Pressure: pascal, bar, atmosphere (technical), atmosphere (standard), torr, psi; Electrical: volts, amps, watts, volt-amperes, volt-amperes reactive, farad, coulomb, ohm, siemen, volt/meter, coulomb/m2, farad/meter, siemen/meter, power factor; Magnetic: weber, tesla, henry, amp/meter, henry/meter; Energy: joule, Btu, calorie; Rotating Machine: radian/second, frequency, revolution/second, revolution/minute, N m, lb-ft, lb-in, oz-in, watt, horsepower; Other: %. |
|
Horizontal - Analog Channels |
Timebases | Internal timebase with 10 GHz clock frequency common to all input channels. Single, distributed 10 GHz clock for all channels ensures precise synchronization with timing accuracy between all channels identical to that provided within a single, conventional oscilloscope package. |
Time/Division Range | 10 ps/div-256 s/div (maximum capture time is based on minimum sample rate of 200kS/s and installed memory). |
Clock Accuracy | <0.1 ppm + (aging of 0.05 ppm/yr from last calibration) |
Sample Clock Jitter | up to 3.2ms Acquired Time Range: 50fsrms (Internal Timebase Reference) 50fsrms (External Timebase Reference) up to 6.4ms Acquired Time Range: 130fsrms (Internal Timebase Reference) 130fsrms (External Timebase Reference) |
Delta Time Measurement Accuracy | \sqrt{2}*\sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2) (RMS)+(clock accuracy*reading)(seconds) |
Jitter Measurement Floor | \sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2\; seconds\; rms\; (TIE)} |
Jitter Between Channels | <250fsrms (TIE, typical, measured at maximum bandwidth) |
Channel-Channel Deskew Range | ±9 x time/div. setting or 25 ns max. (whichever is larger), each channel |
External Timebase Reference (Input) | 10 MHz or 100MHz; 50 Ω impedance, applied at the rear input of MCM-Zi-A Master Control Module |
External Timebase Reference (Output) | 10 MHz or 100 MHz ; 50 Ω impedance, output at the rear of MCM-Zi-A Master Control Module |
|
Acquisition - Analog Channels |
Sample Rate | 80 GS/s |
Maximum Acquisition Memory | 512 Mpts/Ch |
Sample Rate (Single-shot) | 80 GS/s on each channel. |
Memory Length (4 Ch / 2 Ch / 1Ch) (Number of Segments) | 32 M / 32 M / 32M (1000) |
Memory Length Options (4 Ch / 2 Ch / 1Ch) (Number of Segments) | S-32 Option: 32M / 32M / 32M (7,500) M-64 Option: 64M / 64M / 64M (15,000) L-128 Option: 128M / 128M / 128M (15,000) VL-256 Option: 256M / 256M / 256M (15,000) XL-512 Option: 512M / 512M / 512M (15,000) |
Intersegment Time | 1 µs |
Averaging | Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps |
Enhanced Resolution (ERES) | From 8.5 to 11 bits vertical resolution |
Envelope (Extrema) | Envelope, floor, or roof for up to 1 million sweeps |
Interpolation | Linear or Sin x/x |
|
Triggering System |
Max Trigger Frequency (C1-C4, Aux In, SMART Trigger) | For Ch 1-4 only of any LabMaster 10xx-Zi-A Acquisition Module: 2.0 GHz @ ≥ 10 mV/div (minimum triggerable width 200 ps) |
Modes | Normal, Auto, Single, and Stop |
Sources | Any Ch 1-4 (Edge, Window, SMART, Cascade triggers), AUX, internal Fast Edge; or any input channel (Edge trigger only) on additional 10-xxZi-A Acquisition Modules (Channels 5 and higher). Slope and level unique to each source except line trigger. |
Coupling | DC, AC, HFRej, LFRej |
Pre-trigger Delay | 0-100% of memory size (adjustable in 1% increments of 100 ns) |
Post-trigger Delay | 0-10,000 divisions in real time mode, limited at slower time/div settings |
Hold-off | From 2 ns up to 20 s or from 1 to 99,999,999 events |
Trigger and Interpolator Jitter | <0.1 ps rms (typical, software assisted), 2 ps rms (typical, hardware), |
Internal Trigger Level Range | ±4.1 div from center |
External Trigger Level Range | For any LabMaster 10xx-Zi-A Acquisition Module: Aux (±0.4 V) (Only Ch1-4 Acquisition Module has active AUX Input) |
Maximum Trigger Rate | 1,000,000 waveforms/second (in Sequence Mode, up to 4 channels) |
Trigger Sensitivity with Edge Trigger (1.85/2.4/2.92mm Inputs) | For Ch 1-80 of a LabMaster 10 Zi-A system: 3 div @ < 12 GHz 1.5 div @ < 3 GHz 1.0 div @ < 200 MHz (for DC coupling, ≥ 10 mV/div, 50 Ω ) |
Trigger Sensitivity with Edge Trigger (Aux Input) | For Ch 1-4 only of any LabMaster 10xx-Zi-A Acquisition Module: 2 div @ < 1 GHz, 1.5 div @ < 500 MHz, 1.0 div @ < 200 MHz, (for DC coupling) |
|
Trigger Types |
Edge | Triggers when signal meets slope (positive, negative, or either) and level condition. |
Width | Triggers on positive, negative, or both widths with widths selectable as low as 200ps to 20 s, or on intermittent faults. |
Glitch | Triggers on positive or negative glitches with widths selectable as low as 200ps to 20 s, or on intermittent faults. |
Window | Triggers when signal exits a window defined by adjustable thresholds |
Pattern | Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern. |
Runt | Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns. |
Slew Rate | Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns. |
Interval | Triggers on intervals selectable between 1 ns and 20 s. |
Dropout | Triggers if signal drops out for longer than selected time between 1 ns and 20 s. |
Measurement Trigger | Select from a large number of measurement parameters trigger on a measurement value with qualified limits. Can be used as only trigger or last event in a Cascade Trigger. |
Multi-Stage: Qualified (Timeout or State/Edge Qualified) | Triggers on any input source only if a defined state or edge occurred on another input source. Holdoff between sources is selectable by time or events. |
Triggers with Exclusion Technology | Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met |
Multi-Stage: Qualified First | In Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events. |
Multi-Stage: Cascade (Sequence) Trigger, Capability | Arm on A event, then Trigger on B event. Or Arm on A event, then Qualify on B event, and Trigger on C event. |
Multi-Stage: Cascade (Sequence) Trigger, Types | Cascade A then B: Edge, Window, Pattern (Logic) Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage B only. Cascade A then B then C (Measurement): Edge, Window, Pattern (Logic), Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage C only. Cascade A then B then C: Edge, Window, Pattern (Logic) |
Multi-Stage: Cascade (Sequence) Trigger, Holdoff | Holdoff between A and B or B and C is selectable by time or number of events. Measurement trigger selection as the last stage in a Cascade precludes a holdoff setting between the prior stage and the last stage. |
|
High Speed Serial Protocol Trigger |
Data Rates | Option LM10Zi-6GBIT-80B-SYMBOL-TD: 600 Mb/s to 6.5 Gb/s, Channel 4 input only Option LM10Zi-14GBIT-80B-SYMBOL-TD: 600 Mb/s to 14.1 Gb/s, Channel 4 input only |
Pattern Length | 80 bits NRZ, eight 8b/10b symbols, 64b/66b symbol |
|
Display System |
Size | On LabMaster MCM-Zi Master Control Module: Color 15.3 flat panel TFT-Active Matrix LCD with high resolution touch screen |
Resolution | WXGA; 1280 x 768 pixels. |
Number of traces | Display a maximum of 40 traces. Simultaneously display channel, zoom, memory and math traces. |
Grid Styles | Auto, Single, Dual, Triple, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y, Twelve, Sixteen. Up to twenty grids available with some software options. |
Waveform Representation | Sample dots joined, or sample dots only |
|
Integrated Second Display |
Size | Supports touch screen integration of user-supplied second display with split-grid capability. (Note: touch screen driver for second display may not be a Fujitsu driver) |
Resolution | Determined by display chosen by user |
|
LeCroy WaveStream™ Fast Viewing Mode |
Intensity | 256 Intensity Levels, 1-100% adjustable via front panel control |
Types | Select analog or color-graded |
Number of Channels | up to 80 simultaneously |
Max Sampling Rate | 80GS/s |
Persistence Aging | Select from 500 ms to Infinity |
Waveforms/second (continuous) | up to 2500 Waveforms/second |
Operation | Front panel toggle between WaveStream ON (Analog), ON (Color) and OFF |
|
Persistence Display |
Analog and Color-Graded Persistence | Variable saturation levels; stores each trace’s persistence data in memory |
Persistence Types | Select analog, color, or three-dimensional |
Trace Selection | Activate persistence on all or any combination of traces |
Persistence Aging | Select from 500 ms to infinity |
Sweep Display Modes | All accumulated, or all accumulated with last trace highlighted |
|
High Speed Digitizer Output (Option) |
Type | Option LSIB-2. Installs in LabMaster MCM-Zi Master Control Module and uses one available PCIe slot normally used by a LabMaster 10-xxZi Acquisition Module. |
Transfer Rate | up to 325 MB/s (typical) - Maximum of 4 channels (consult Teledyne LeCroy for >4 channels) |
Output Protocol | PCI Express, Gen 1 (4 lanes utilized for data transfer) |
Control Protocol | TCP/IP |
Command Set | Via Windows Automation, or via LeCroy Remote Command Set |
|
Zoom Expansion Traces |
Zoom Expansion Traces | Display up to 12 Zoom and 12 Math/Zoom traces |
|
Internal Waveform Memory |
Internal Waveform Memory | 12 active waveform memory traces (M1-M12) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity. |
|
Setup Storage |
Front Panel and Instrument Status | Store to the internal hard drive, over the network, or to a USB-connected peripheral device. |
|
Automatic Setup |
Auto Setup | Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals |
Find Vertical Scale | Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range |
|
Calibration |
Auto Calibration | Ensures specified DC and timing accuracy is maintained for 1 year minimum. |
|
Processor/CPU |
Processor Memory | 32 GB standard. Up to 192 GB optionally available. |
Operating System | Microsoft Windows® 10 |
Oscilloscope Operating Software | Teledyne LeCroy MAUI™ with OneTouch |
Real Time Clock | Date and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks. |
|
Connectivity |
Ethernet Port | Supports 10/100/1000BaseT Ethernet interface (RJ45 port) |
USB Host Ports | LabMaster MCM-Zi -A Master Control Module: minimum 2 total USB 2.0 ports on rear of unit to support Windows compatible devices LabMaster MCM-Zi -A Master Control Module: minimum 3 total USB 2.0 ports on front of unit to support Windows compatible devices |
GPIB Port (optional) | Supports IEEE - 488.2. Installs in LabMaster MCM-Zi Master Control Module and uses one available PCIe slot normally used by a LabMaster 10-xxZi Acquisition Module. |
External Monitor Port | Dual Link DVI compatible to support internal display on MCM-Zi Master Control Module (1280 x 768 pixel resolution) and customer-supplied monitor with up to WQXGA (2560 x 1600 pixel) resolution using extended desktop mode. |
Remote Control | Via Windows Automation, or via LeCroy Remote Command Set |
Network Communication Standard | VXI-11 or VICP, LXI Class C (v1.2) Compliant |
LSIB Port (optional) | Supports PCIe Gen1 x4 protocol with LeCroy supplied API. Installs in LabMaster LabMaster MCM-Zi-A Master Control Module and uses one available PCIe slot normally used by a LabMaster 10-xxZi-A Acquisition Module. |
|
Auxiliary Input |
Signal Types | For External Trigger Input. Located on every LabMaster 10-xxZi-A Acquisition Module (front-mounted BNC, 50 Ω). 10-xxZi-A Acquisition Module that is used for Channels 1-4 contains active AUX Input. |
Coupling | 50 Ω: DC |
Max. Input Voltage | 5 Vrms |
|
Auxiliary Output |
Signal Types | Select from calibrator, control signals or Off |
Output Signal | 500 Hz-5 MHz square wave or DC level; 0.0 to 500 mV into 50 Ω (0-1 V into 1 MΩ) |
Control Signals | Trigger enabled, trigger out, pass/fail status, off |
Connector Type | BNC, located on front of every LabMaster 10-xxZi Acquisition Module. 10-xxZi Acquisition Module that is used for Channels 1-4 contains active AUX Output. |
|
Probes |
Probing System | 2.92mm interface automatically detects and supports a variety of compatible probes. Use L2.92A-PLINK or L2.92A-PBUS 2.92mm Probe Adapters to connect 50Ω ProLink or 50Ω ProBus compatible probes to 2.92mm interface. |
Probes
| No passive probes supplied |
Scale Factors | Automatically or manually selected depending on probe used |
Calibration Output | MCM-Zi-A Master Control Module: Fast Edge output, 5MHz square wave, 350mVp-p (typical), 50ps rise time, output to SMA connector, AC Coupled |
|
Power Requirements |
Voltage | LabMaster 10-xxZi Acquisition Module: 100-240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection, Installation Category II LabMaster MCM-Zi Master Control Module: 100-240 VAC ±10% at 45-66 Hz; Automatic AC Voltage Selection, Installation Category II |
Max. Power Consumption | LabMaster 10-xxZi-A Acquisition Module - 1225 W / 1225 VA. LabMaster MCM-Zi-A Master Control Module - 450 W / 450 VA. Each Module and the CPU has a separate power cord. |
|
Environmental |
Temperature (Operating) | +5 °C to +40 °C |
Temperature (Non-Operating) | -20 °C to +60 °C |
Humidity (Operating) | 5% to 80% relative humidity (non-condensing) up to +31 °C. Upper limit derates to 50% relative humidity (non-condensing) at +40 °C. |
Humidity (Non-Operating) | 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F |
Altitude (Operating) | Up to 10,000 ft. (3048 m) at or below +25 °C |
Altitude (Non-Operating) | Up to 40,000 ft. (12,192 m) |
Random Vibration (Operating) | 0.5 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes |
Random Vibration (Non-Operating) | 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes |
Functional Shock | 20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total |
|
Size and Weight |
Dimensions (HWD) | LabMaster MCM-Zi-A Master Control Module - 10.9H x 18.2W x 15.6D (277 x 462 x 396 mm), LabMaster 10-xxZi-A Acquisition Module - 8.0H x 18.2W x 26D (202 x 462 x 660 mm) |
Weight | LabMaster 10-xxZi-A Acquisition Module -53 lbs. (24.1 kg) LabMaster MCM-Zi-A Master Control Module - 47 lbs. (21.4 kg), |
Shipping Weight | LabMaster 10-xxZi-A Acquisition Module -71 lbs. (32.3 kg) LabMaster MCM-Zi-A Master Control Module - 56 lbs. (25.5 kg) |
|
Certifications |
CE Certification UL and cUL Listing | CE Compliant, UL and cUL listed; conforms to EN 61326, EN 61010-1, EN61010-2-030, UL 61010-1 3rd edition, and CSA C22.2 No. 61010-1-12 |
|
Warranty and Service |
Warranty and Service | 3-year warranty; calibration recommended annually. Optional service programs include extended warranty, upgrades, and calibration services. |
|