Products
Oscilloscope Probes
product series title image

T3RC Rogowski Coil Current Probes

Teledyne Test Tools Rogowski Current probes offer a broad range of products covering a wide frequency span and current measurement ranges for maximum application coverage whilst being easy to use in difficult to reach parts of the circuit.

Explore T3RC Rogowski Coil Current Probes arrow down icon
  • product line tab
  • overview tab

   T3RC Rogowski Coil Current Probes


T3RC0060-LF - AC Current Probe 100 mV/A, 60A, 11 Hz LF Bandwidth, 5MHz HF Bandwidth, 1m cable.
T3RC0120-UM - AC Current Probe 50 mV/A, 120A, 34 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable.
T3RC0300-UM - AC Current Probe 20 mV/A, 300A, 9.2 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable.
T3RC0600-HF - AC Current Probe 10 mV/A, 600A, 12 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable.
T3RC3000-HF - AC Current Probe 2 mV/A, 3,000A, 3 Hz LF Bandwidth, 23MHz HF Bandwidth, 4m cable, 200mm coil.
T3RC3000-LF - AC Current Probe 2 mV/A, 3,000A, 0.11 Hz LF Bandwidth, 6.5MHz HF Bandwidth, 4m cable, 300mm coil.
T3RC6000-LF - AC Current Probe 1 mV/A, 6,000A, 0.055 Hz LF Bandwidth, 6.5MHz HF Bandwidth, 4m cable, 300mm coil.
T3RC Rogowski Coil Current Probes

Teledyne Test Tools Rogowski Current probes offer a broad range of products covering a wide frequency span and current measurement ranges for maximum application coverage whilst being easy to use in difficult to reach parts of the circuit.

The flexibility of the probe sense coil means that measurements can often be made without modification to the circuit under test, giving more accurate results, whilst remaining isolated, with very low insertion load of only a few pH.

The inclusion of both battery power and wall plug operation means that the Teledyne Test Tools Rogowski Current Probes are as happy working out in the field as they are working on the bench.

The T3RC0300-UM and T3RC0120-UM features our smallest cross section sense coil at only 1.7mm. This ideally lends itself to embedded power applications where it’s necessary to probe around the leg of power components such as inductors, capacitors or small switching devices as small as a TO220 MOSFET.

The T3RC0600-HF and T3RC3000-HF are general purpose Rogowski probes covering applications up to 600 Amps and 3000 Amps respectively. With extended high frequency coverage, 5 kV peak insulation and wide operating temperature range from -40C to +125C, makes them ideally suited to both general purpose as well as wide temperature environments.

The T3RC3000-LF and T3RC6000-LF Rogowski probes offer an extended low frequency performance down to less than 1 Hz. The low frequency performance means that the maximum droop on low frequency pulses is typically 0.1% / ms or less, whilst offering our highest level of peak insulation of 10 kV and wide operating temperature range of -20C to +100C.

The T3RC0060-LF is our highest sensitivity Rogowski probe with an maximum measurement range of 60 Amps with a 2 kV insulation and a wide operating temperature of -20C to +100C.

Main Features
  • 7 different probes covering a wide range of applications.
  • Maximum current measurement coverage up to 6000 Amps.
  • Maximum voltage insulation up to 10 kV peak.
  • Connect to a wall plug or use with batteries.
  • Low loading of the circuit under test.
  • Wide coil operating temperature from -40 C to +125 C on UM and HF probes
    -20 C to +100 C for LF probes.
  • Use without modification to the DUT.
 
Oscilloscope Compatibility

The Teledyne Test Tools Rogowski probes are compatible with all of the Teledyne Test Tools Oscilloscopes as well as the Teledyne LeCroy Oscilloscopes.

The Teledyne Test Tools Rogowski probes have a simple connection requirement of a BNC input with 1 MOhm impedance. These probes will therefore work with the majority of oscilloscopes in the market.

The probes can be made even more useful by using your Oscilloscope's Attenuation function to re-scale the Channel vertical range.

Application Fields
  • Component level design and development such as semiconductor switching waveforms in MOSFET or IGBT, also capacitor and inductor devices.
  • System level development such as motor drives in hybrid and fully electric transportation systems (automotive, rail, sea, etc)
  • Power converter design and development for wind farms and other renewable energy.
  • Research and Development.
  • Long term system monitoring and maintenance.
 
Physical Specifications
Model Coil Circumference Cable Length (coil to electronics) Peak Coil Insulation Voltage Coil Thickness
T3RC0060-LF 100 mm 1 m 2 kV 3.5mm
T3RC0120-UM 80 mm 1 m 1.2 kV 1.7mm
T3RC0300-UM 80 mm 1 m 1.2 kV 1.7 mm
T3RC0600-HF 100 mm 1 m 5 kV 4.5mm
T3RC3000-HF 200 mm 4 m 5 kV 4.5mm
T3RC3000-LF 300 mm 4 m 10 kV 8.5mm
T3RC6000-LF 300 mm 4 m 10 kV 8.5mm
 
Electrical Specifications
Model Sensitivity Peak Current Max Noise Droop (%/ms) LF (-3dB) Bandwidth HF (-3dB) Bandwidth Peak di/dt Division Ratio
T3RC0060-LF 100 mV/A 60 A 2.6 mV rms 11 11 Hz 5 MHz 14 kA/us 10
T3RC0120-UM 50 mV/A 120 A 2.5 mV rms 35 34 Hz 30 MHz 8 kA/us 20
T3RC0300-UM 20 mV/A 300 A 2.5 mV rms 9 9.2 Hz 30 MHz 20 kA/us 50
T3RC0600-HF 10 mV/A 600 A 1.7 mV rms 11 12 Hz 30 MHz 40 kA/us 100
T3RC3000-HF 2 mV/A 3000 A 1.4 mV rms 2.8 3 Hz 23 MHz 80 kA/us 500
T3RC3000-LF 2 mV/A 3000 A 2.5 mV rms 0.1 0.11 Hz 6.5 MHz 11 kA/us 500
T3RC6000-LF 1 mV/A 6000 A 2.5 mV rms 0.05 0.055 Hz 6.5 MHz 11 kA/us 1000