WaveSurfer 4024HD Oscilloscope

WaveSurfer 4024HD

200 MHz, 5 GS/s, 4 Ch, 12.5 Mpts/ch DSO with 12.1" Capacitive Touch Screen Display


  • product line tab
  • overview tab
  • specs tab
  • options tab
  • probes tab
WaveSurfer 4024HD   (200 MHz Bandwidth, 4 Input Channels, 12.5 Mpts/ch, 5 GS/s)
Quick Specs
Sample Rate2.5 GS/s on 4Ch
Maximum Acquisition Memory25 Mpts (2 Ch operation)
Input Channels4
Vertical Resolution12-bits
WaveSurfer 4034HD   (350 MHz Bandwidth, 4 Input Channels, 12.5 Mpts/ch, 5 GS/s)
Quick Specs
Sample Rate2.5 GS/s on 4Ch
Maximum Acquisition Memory25 Mpts (2 Ch operation)
Input Channels4
Vertical Resolution12-bits
WaveSurfer 4054HD   (500 MHz Bandwidth, 4 Input Channels, 12.5 Mpts/ch, 5 GS/s)
Quick Specs
Sample Rate2.5 GS/s on 4Ch
Maximum Acquisition Memory25 Mpts (2 Ch operation)
Input Channels4
Vertical Resolution12-bits
WaveSurfer 4104HD   (1 GHz Bandwidth, 4 Input Channels, 12.5 Mpts/ch, 5 GS/s)
Quick Specs
Sample Rate2.5 GS/s on 4Ch
Maximum Acquisition Memory25 Mpts (2 Ch operation)
Input Channels4
Vertical Resolution12-bits
Check up to three models.
Key Features
  • Highest resolution – 12 bits all the time
  • More capability – integrates multiple instruments into one
  • Comprehensive probe support – supports over 30 probes in 9 categories
  • MAUI with OneTouch user interface for intuitive and efficient operation

 

HD4096 – 12 Bits All the Time, 16 x Closer to Perfect

Teledyne LeCroy high definition 12-bit oscilloscopes use unique HD4096 technology to provide superior and uncompromised measurement performance. HD4096 technology provides the highest resolution and lowest noise at full bandwidth—12 bits all the time with no compromise.

 

More Capability Than You Imagined

A suite of options for power, serial bus and embedded systems debug

  • Multi-instrument options
  • Serial trigger and decode software
  • Spectrum & power analysis software

 

Comprehensive Probe Support

Over 30 probes in 9 categories

  • Active power rail probes
  • Current probes
  • High-Voltage differential and fiber optic probes
  • TekProbe adapters

 

MAUI with OneTouch
  • Most unique touch screen features on any oscilloscope
  • Drag-and-drop to dramatically reduce setup time
  • All common operations can be performed with one touch

 

Vertical - Analog Channels

Analog Bandwidth (Max) 200 MHz
Bandwidth 200 MHz
Analog Bandwidth @ 50 Ω (-3 dB) (ProBus Input) 200 MHz
Analog Bandwidth @ 1 MΩ (-3 dB) (ProBus Input) 200 MHz
Rise Time (10-90%, 50 Ω) 1.75 ns
Input Channels 4
Vertical Resolution 12 bits; up to 15 bits with enhanced resolution (ERES)
Effective Number of Bits (ENOB) 8.6
Vertical Noise Floor (1 mV/div) 65 uVrms
Vertical Noise Floor (2 mV/div) 65 uVrms
Vertical Noise Floor (5 mV/div) 65 uVrms
Vertical Noise Floor (10 mV/div) 69 uVrms
Vertical Noise Floor (20 mV/div) 94 uVrms
Vertical Noise Floor (50 mV/div) 162 uVrms
Vertical Noise Floor (100 mV/div) 270 uVrms
Vertical Noise Floor (200 mV/div) 963 uVrms
Vertical Noise Floor (500 mV/div) 1.63 mVrms
Vertical Noise Floor (1 V/div) 2.70 mVrms
Sensitivity 1 MΩ: 1 mV/div - 10 V/div, fully variable;
50 Ω: 1 mV/div - 1 V/div, fully variable
DC Vertical Gain Accuracy (Gain Component of DC Accuracy) ±(0.5%) FS, offset at 0 V
Channel-Channel Isolation 60 dB
(For any two ProBus input channels, same v/div settings, typical)
Offset Range 50 Ω
±1.6 V @ 1 mV - 4.95 mV/div
±4 V @ 5 mV - 9.9 mV/div
±8 V @ 10 mV - 19.8 mV/div
±10 V @ 20 mV - 1 V/div

1 MΩ
±1.6 V @ 1 mV - 4.95 mV/div
±4 V @ 5 mV - 9.9 mV/div
±8 V @ 10 mV - 19.8 mV/div
±16 V @ 20 mV - 100 mV/div
±80 V @ 102 mV - 198 mV/div
±160 V @ 200 mV - 1 V/div
±400 V @ 1.02 V - 10 V/div
DC Vertical Offset Accuracy ±(1.0% of offset setting + 0.5% FS + 0.02% of max offset + 1mV)
Maximum Input Voltage 50 Ω: 5 Vrms,
1 MΩ: 400 V max
(DC + Peak AC ≤ 10 kHz)
Input Coupling 1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Input Impedance 50 Ω ± 2.0% or 1 MΩ || 15 pF
Bandwidth Limiters 20 MHz
Rescaling Electrical: volts, amps
 

Horizontal - Analog Channels

Timebases Internal timebase common to 4 input channels
Acquisition Modes Real-time, Roll, Average, Sequence
Time/Division Range 500 ps/div - 100 s/div
Roll Mode available at ≥ 50 ms/div
Clock Accuracy +/-2.5ppm + 1.0ppm/year from calibration
Channel-Channel Deskew Range < 5us/div, ± 100 ns, each channel
≥ 5us/div, ± (Tdiv x 0.04), each channel
 

Acquisition - Analog Channels

Sample Rate (Single-shot) 5 GS/s on 2 Ch
2.5 GS/s on 4 Ch
Memory Length (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
12.5M / 25M
(1,000)
Intersegment Time 1 µs
Enhanced Resolution (ERES) From 12.5 to 15 bits vertical resolution
Envelope (Extrema) Envelope, floor, or roof for up to 1 million sweeps
 

Vertical, Horizontal, Acquisition - Digital Channels

Maximum Input Frequency 125 MHz
Minimum Detectable Pulse Width 4 ns
Input Channels 16 Digital channels (with WS4KHD-MSO option)
Input Impedance (Flying Leads) 100 kΩ || 5 pF
Input Dynamic Range ±20V
Maximum Input Voltage ±30V Peak
Minimum Input Voltage Swing 500mVpp
Threshold Groupings Pod 2: D15 - D8, Pod 1: D7 - D0
Threshold Selections TTL (+1.4V), 5V CMOS (+2.5V), ECL (-1.3V), or User Defined
Threshold Accuracy ±(3% of threshold setting + 100mV)
User Defined Threshold Range ±10V in 20 mV steps
Sample Rate 500 MS/s
Record Length 12.5 MS - 16 Channels
Channel-to-Channel Skew ±(1 digital sample)
 

Triggering System

Max Trigger Frequency (C1-C4, Aux In, SMART Trigger) 200MHz
Modes Normal, Auto, Single, Stop
Sources Ch 1 - Ch 4, EXT, EXT/5, AC Line
Coupling DC, AC, HFRej, LFRej
Pre-trigger Delay 0-100% of memory size
Post-trigger Delay 0 - 10,000 Divisions
Hold-off 10 ns up to 20s or from 1 to 100,000,000
Trigger and Interpolator Jitter ≤ 8 psrms (typical)
Internal Trigger Level Range ±4.1 Divisions
External Trigger Level Range Ext: ±0.61 V, EXT/5: ±3.05 V
Maximum Trigger Rate ≤ 175,000 waveforms/second
Trigger Sensitivity with Edge Trigger ProBus Inputs 0.9 division: DC - 10 MHz
1 division: 10 MHz - 200 MHz
Trigger Sensitivity with Edge Trigger (Aux Input) Ext: 200 mV from DC to 10 MHz
300 mV from 10 MHz to 200 MHz
Ext/5: 1 V from DC to 10 MHz
1.5 V from 10 MHz to 200 MHz
 

Trigger Types

Edge Triggers when signal meets slope (positive, negative, or either) and level condition.
Width Triggers on positive or negative glitches with selectable widths.
minimum width 2 ns, Maximum Width: 20 s
Window Triggers when signal exits a window defined by adjustable thresholds
Pattern Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern.
TV-Composite Video Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative).
Runt Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew Rate Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
Interval Triggers on intervals selectable between 1 ns and 20 s.
Dropout Triggers if signal drops out for longer than selected time between 1 ns and 20 s.
Multi-Stage: Qualified (Timeout or State/Edge Qualified) Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time.
Triggers with Exclusion Technology Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
 

Low Speed Serial Protocol Trigger (Optional)

Supported Protocols I2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN1.1, CAN2.0, CAN FD, LIN, FlexRay, AudioBus (I2S, LJ, RJ, TDM)
 

Measurement Tools

Measurement Functionality Display up to 6 measurement parameters together with statistics, including mean, minimum, maximum, standard deviation, and total number. Each occurrence of each parameter is measured and added to the statistics table. Histicons provide a fast, dynamic view of parameters and waveshape characteristics. Parameter gates define the location for measurement on the source waveform.
Measurement Parameters - Horizontal + Jitter Delay (from trigger, 50%), Duty Cycle, Fall Time (90-10, 80-20), Frequency, Period, Δ Period, Phase, Rise Time (10-90, 20-80), Skew, Width+, Width-
Measurement Parameters - Vertical Amplitude, Base, Maximum, Mean, Minimum, Peak-to-Peak, RMS, Std. Deviation, Top.
Measurement Parameters - Pulse Area, Base, Fall Time (90-10, 80-20), Overshoot (positive, negative), Rise Time (10-90, 80-20), Top, Width+, Width-
 

Math Tools

Math Functionality Display up to 2 math functions traces (F1-F2). The easy-to-use graphical interface simplifies setup of up to two operations on each function trace, and function traces can be chained together to perform math-on-math.
Math Operators - Basic Math Average (summed), Average (continuous), Difference (-), Envelope, Floor, Invert (negate), Product (x), Ratio (/), Reciprocal, Rescale (with units), Roof, Sum (+).
Math Operators - Filters Enhanced resolution (to 15 bits vertical)
Math Operators - Frequency Analysis FFT (power spectrum, magnitude), up to 500 kpts record length. Select from Rectangular, VonHann, Hamming, FlatTop and Blackman Harris windows.
Math Operators - Functions Derivative, Integral, Invert (negate), Rescale (with units), Square, Square root, Zoom (identity).
 

Measurement and Math Integration

Measurement and Math Integration Trend (datalog) of up to 1000 measurement parameters
 

Pass/Fail Testing

Pass/Fail Testing Mask Test (pre-defined or user-defined mask, waveform All In, All Out, Any In, or Any Out conditions) with following THEN Save (waveforms), Stop, Alarm, (send) Pulse, Hardcopy (send email, save screen image, save to clipboard, send to printer), or (save) LabNotebook.
 

Display System

Size Color 12.1 widescreen capacitive touch screen
Resolution 1200 x 800
Number of traces Display a maximum of 8 traces. Simultaneously display channel, zoom, memory and math traces.
Grid Styles Auto, Single,X-Y, Single+X-Y
Waveform Representation Sample dots joined, or sample dots only
 

Persistence Display

Analog and Color-Graded Persistence Variable saturation levels; stores each trace’s persistence data in memory
Persistence Types Select analog or color
Trace Selection Activate persistence on all traces
Persistence Aging Select from 1.00 s to infinity
 

Zoom Expansion Traces

Zoom Expansion Traces Display up to 8 Zooms
 

Internal Waveform Memory

Internal Waveform Memory 4 active waveform memory traces (M1-M4) store 16 bit/point full length waveforms. Waveforms can be stored on the internal microSD card or external USB device, limited only by the data storage media capacity
 

Setup Storage

Front Panel and Instrument Status Store to the internal microSD, over the network, or to a USB-connected peripheral device.
 

Automatic Setup

Auto Setup Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical Scale Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range
 

Calibration

Auto Calibration Ensures specified DC and timing accuracy is maintained for 1 year minimum.
Calibration Stability Calibration ensured within +/-5°C operating temperature. Manual calibration may be invoked if outside this temperature range.
 

Processor/CPU

Type TI AM5728 Sitara Processor
Processor Memory 2 GB
Operating System Microsoft Windows CE
Oscilloscope Operating Software Teledyne LeCroy MAUI™
Real Time Clock Date and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks.
 

Connectivity

Ethernet Port Supports 10/100BaseT Ethernet interface (RJ45 port)
USB Host Ports 2 side USB 2.0 ports, 2 front USB 3.1 Gen 1 ports
USB Device Port 1 port - USBTMC over USB 2.0
GPIB Port (optional) Supports IEEE - 488.2 (External)
External Monitor Port 1 x HDMI, supports up to 1280x800
Remote Control Via Windows Automation, or via LeCroy Remote Command Set
Network Communication Standard VXI-11 or VICP, LXI Compatible
 

Auxiliary Input

Signal Types Select External Trigger on the rear panel
Coupling 50 Ω: DC; 1 MΩ: DC
Max. Input Voltage 50 Ω: 5 Vrms; 1 MΩ: 250 Vmax (DC + Peak AC ≤ 10 kHz)
 

Auxiliary Output

Signal Types Always Trig Out
Output Signal 3.3 V into 1 MΩ pulse > 1.3 ms
Control Signals Trigger out
Connector Type BNC, located on back
 

Probes

Probing System ProBus. Automatically detects and supports a variety of compatible probes
Probes Qty. (4) ÷10 Passive Probes
Scale Factors Automatically or manually selected depending on probe used
Calibration Output Default is 1kHz square wave, 3.3Vp-p (typical), output to probe hook. Settable from 500 Hz to 1 MHz square wave
 

Power Requirements

Voltage 100-240 VAC ±10% at 50-60 ±10% Hz; 110-120 VAC ±10% at 400 ±5% Hz; Automatic AC Voltage Selection
Max. Power Consumption 150 VA
 

Environmental

Temperature (Operating) 0 °C to 50 °C
Temperature (Non-Operating) -30 °C to 70 °C
Humidity (Operating) 5% to 90% relative humidity (non-condensing) up to ≤ +31 °C.
Upper limit derates to 50% relative humidity (non-condensing) at +50 °C.
Humidity (Non-Operating) 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating) Up to 10,000 ft. (3048 m) at or below +30 °C
Altitude (Non-Operating) Up to 40,000 ft. (12,192 m)
 

Size and Weight

Dimensions (HWD) 10.74H x 14.96W x 6.30D (273 mm x 380 mm x 160 mm)
Weight 11.7 lbs (5.3 kg)
Shipping Weight 20.06 lbs (9.1 kg)
 

Certifications

CE Certification
UL and cUL Listing
CE Compliant, UL and cUL listed; conforms to
UL 61010-1 (3rd Edition), UL 61010-2-030 (1st Edition)
CAN/CSA C22.2 No. 61010-1-12
 

Warranty and Service

Warranty and Service 3-year warranty; calibration recommended annually.
Optional service programs include extended warranty, upgrades, and calibration services.
 

Mixed Signal Option

WS4KHD-MSO
Mixed Signal Option for WaveSurfer 4000HD (includes probe, accessories, and license)

Remote Control/Network Options

USB2-GPIB
External USB 2.0 to GPIB IEEE 488.2 adapter

Power Analysis Software

WS4KHD-PWR
Power Analysis Option for WaveSurfer 4000HD

Serial Trigger and Decode

WS4KHD-AUDIO TD
AudioBus trigger and decode option for WaveSurfer 4000HD
WS4KHD-AUTO TD
Automotive SW bundle (CAN, CAN FD, LIN & FlexRay) for WaveSurfer 4000HD
WS4KHD-EMB TD
Embedded SW bundle (I2C, SPI, UART/RS232) for WaveSurfer 4000HD

Other Software Options

WS4kHD-SPECTRUM-1
Spectrum Analyzer for WaveSurfer 4000HD - 1 trace
WS4KHD-FG
Function Generator for WaveSurfer 4000HD

Miscellaneous

WS4KHD-SOFTCASE
WaveSurfer 4000HD Softcase
WS4KHD-RACK
WaveSurfer 4000HD Rackmount kit

Active Voltage Probes

ZS1500
1.5 GHz, 0.9 pF, 1 MOhm Active Voltage Probe
ZS1000
1 GHz, 0.9 pF, 1 MOhm Active Voltage Probe

Differential Probes (<= 1.5 GHz)

AP033
500 MHz Differential Probe
ZD200
200 MHz, 3.5 pF, 1 MOhm Active Differential Probe, ±20 V Limited Availability
ZD500
500 MHz, 1.0 pF Active Differential Probe, ±8 V
ZD1000
1 GHz, 1.0 pF Active Differential Probe, ±8 V
ZD1500
1.5 GHz, 1.0 pF Active Differential Probe, ±8 V

Current Probes

CP150
150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 2 meter cable Limited Availability
CP500
500 A, 2 MHz Current Probe - AC/DC, 500 A rms, 700 A Peak Pulse, 6 meter cable
CP030
30A, 50 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable Limited Availability
CP031
30A, 100 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP030A
30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable Limited Availability
CP031A
30A, 100 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP030-3M
30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 3 meter cable Limited Availability
CP150-6M
150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 meter cable Limited Availability
DCS025
Deskew Calibration Source for Teledyne LeCroy current probes
CP150B
150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 2 meter cable
CP030B
30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable

High Voltage Passive Probes

HVP120
6kV High Voltage Passive Probe, 400 MHz
PPE6KV-A
6kV High Voltage Passive Probe, 500 MHz

Passive Probes

PP019-1
250 MHz Passive Probe for WaveSurfer 3000, 10:1, 10 MOhm
PP026-1
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm

High Voltage Differential Probes

AP031
700 V, 25 MHz High-Voltage Differential Probe (÷10, ÷100) Limited Availability
HVD3102A
1kV, 25 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3102A-NOACC
1kV, 25 MHz High Voltage Differential Probe without tip Accessories and with Auto Zero Disconnect
HVD3106A
1kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3106A-NOACC
1kV, 120 MHz High Voltage Differential Probe without tip Accessories and with Auto Zero Disconnect
HVD3106A-6M
1kV, 80 MHz High Voltage Differential Probe with 6m cable and Auto Zero Disconnect
HVD3206A
2kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3206A-6M
2kV, 80 MHz High Voltage Differential Probe with 6m cable and Auto Zero Disconnect
HVD3605A
6kV, 100 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3220
2kV, 400 MHz High Voltage Differential Probe

Probe Adapters

TPA10
TekProbe to ProBus Probe Adapter

Active Voltage Rail Probe

RP4030
Power/Voltage Rail Probe. 4 GHz bandwidth, 1.2x attenuation, +/-30V offset, +/-800mV Includes a complete set of solder-in leads, coaxial cables, and PCB mounts. Limited Availability
RP4000-BROWSER
RP2060/RP4060 Browser Tip accessory. Includes 0 Ohm (1x), 450 Ohm (10x) and 950 Ohm (20x) tips.
RP4060
Power/Voltage Rail Probe. 4 GHz bandwidth, 1.2x attenuation, +/-60V offset, +/-800mV Includes a complete set of solder-in leads and coaxial cables. Browser tip sold seperately
RP2060
Power/Voltage Rail Probe. 2 GHz bandwidth, 1.2x attenuation, +/-60V offset, +/-800mV Includes a complete set of solder-in leads and coaxial cables. Browser tip sold seperately

High Voltage Optically Isolated Probes

HVFO100-1X-TIP-U
HVFO10X +/-1V (1x Attenuation) Universal Tip Accessory
HVFO100-5X-TIP-U
HVFO10X +/-5V (5x Attenuation) Universal Tip Accessory
HVFO100-10X-TIP-U
HVFO10X +/-10V (10x Attenuation) Universal Tip Accessory
HVFO100-20X-TIP-U
HVFO10X +/-20V (20x Attenuation) Universal Tip Accessory
HVFO100-40X-TIP-U
HVFO10X +/-40V (40x Attenuation) Universal Tip Accessory
HVFO108
High Voltage Fiber Optic Probe, 150 MHz Bandwidth. Includes soft-carrying case. Requires attenuating tip (ordered separately). Includes Qty. 1 1m Fiber Optic Cable.

60 V Common Mode Differential Probes

DL05-HCM
500 MHz 60 V Common Mode Differential Probe. Includes standard set of leads and tips.
DL10-HCM
1 GHz 60 V Common Mode Differential Probe. Includes standard set of leads and tips.
DL-HCM-HiTemp
DL-HCM series high-temperature solder-in tip, 30 MHz bandwidth, 1 meter length.
DL-HCM-Acc-Kit
DL-HCM series accessories kit with probe holder, micro IC grabbers (Qty 2.), and Y-banana adaptor.
DL02-HCM
250 MHz 60 V Common Mode Differential Probe. Includes standard set of leads and tips.