USB Compliance Is Only The Start – Teledyne LeCroy Helps You Find Why Real USB-C Links Fail

USB-C has become the universal converged interface for data, display, power, and sideband control. Higher speeds in USB4 require more testing on more lanes, and the convergence makes compliance and interoperability failures harder to find, reproduce, and fix. Engineers need:

  • Faster automated pre-compliance and compliance testing
  • Offline compliance test analysis to reduce lab bottlenecks
  • Synchronized PHY, protocol, and sideband visibility to find the root cause of interoperability failures on real links that have passed compliance

USB and USB-C Test Challenges, Market Needs and Solutions

USB-C product teams must prove standards compliance and real-world interoperability across a multi-layer, multi-technology interface, but traditional test workflows are too slow, too fragmented, and often do not reveal the true root cause of failures.

USB-C compliance testing to the USB-IF CTS  using a Teledyne LeCroy oscilloscope and an Anritsu MP1900A BERT
Typical USB-C host system block diagram
USB-C link testing with cross-layer analysis and PHY-logic debug using Teledyne LeCroy oscilloscope, protocol analyzer, CrossSync PHY software, and USB test coupon fixtures for cross-layer analysis
Image of USB4 compliance test report (per the USB-IF CTS) and a USB-C interoperability debug setup using a Teledyne LeCroy oscilloscope, protocol analyzer, test coupon fixture and CrossSync PHY software

Engineers need to complete an extensive range of compliance tests quickly, accurately, and repeatedly.

  • USB compliance test to USB-IF standards requires a comprehensive range of transmitter, receiver, sideband, power delivery, repeater, cable/connector and return loss tests.
  • Newer, higher-speed USB standards (e.g., USB4) add more lanes at higher speeds and more tests to the compliance test specification (CTS), creating test bottlenecks
  • Setup complexity and human error impact test efficiency and test quality, especially when test procedures change.
  • PHY compliance test alone is not sufficient to understand real-world USB system performance

Products may pass compliance but still fail in a real USB ecosystem due to poor synchronization between electrical (high-speed PHY), sideband and protocol behaviors during link negotiation and active operation. This results in end-user dissatisfaction with real-world performance.

  • Formal USB-IF CTS success can still result in compliance tested products failing in real-world links.
  • Higher-speed USB links and long channels require the use of linear redrivers, retimers and LTTPRs, increasing design complexity and the likelihood of link training failures.
  • Cross-layer failure ambiguity results in difficult to debug failures because failures could be electrical/PHY-related, protocol/logic-related, or a combination of both PHY and logic (common during sideband negotiations).
  • Interoperability failures are economically painful because they impact the end-user and are organizationally difficult to source and resolve.

Testing converged USB-C links and/or higher-speed USB4 links is fundamentally different than testing USB 3.2 and previous USB interfaces. Products can pass formal PHY compliance and still fail during link training, sideband negotiation, or real-world interoperability.

  • Tx, Rx and Return Loss compliance needs to be better integrated and completely automated to reduce the increased knowledge burden on the test engineers.
  • Pre-compliance and compliance testing needs to be faster and more efficient due to the increased test requirements - compliance test data processing needs to be moved from the acquisition engine (oscilloscope) to a separate PC.
  • The oscilloscope needs to be focused on debugging Interoperability failures that result in end-user dissatisfaction – a compliance “pass” does not guarantee proper interoperability with today’s high-speed USB4 links and long channels

Teledyne LeCroy is uniquely positioned to provide fast, efficient compliance testing, the most capable high-speed serial link debug when compliance failures occur, and unique cross-layer debug tools to debug PHY-logic interoperability problems on live links.

  • The WaveMaster® 8000HD oscilloscope is the best oscilloscope for low and high-speed USB-C testing. It combines high-speed and sideband testing into a single test oscilloscope – the only oscilloscope with these capabilities.
  • QualiPHY 2 automated compliance test framework provides validation and compliance in a fraction of the time and QPHY2-PC permits more efficient offline testing and completes compliance testing faster.
  • Unmatched USB-C link testing with cross-layer analysis on live links for better interoperability debug

All-In-One Solution For USB and USB-C® Electrical Compliance and Debug

Teledyne LeCroy provides the best electrical, protocol and cross-layer (PHY-logic) solutions for USB-C Testing, including USB4®, Thunderbolt™, USB 3.2, USB 2.0, DisplayPort® 2.1, and USB Power Delivery, all over the USB Type-C Connector.

The WaveMaster 8000HD oscilloscope with callouts supporting its application in USB Type-C high-speed testing and USB-C sideband testingThe WaveMaster 8000HD oscilloscope with callouts supporting its application in USB Type-C high-speed testing and USB-C sideband testing

An All-In-One Oscilloscope for All USB-C Compliance and Debug Testing

The WaveMaster 8000HD oscilloscope combines high-speed and sideband testing into a single instrument.
  • Four 25 GHz, 80 GS/s inputs with 12-bit resolution for multi-lane compliance testing.
  • Four 2 GHz, 1 MΩ-compatible input channels for sideband signal probing.
  • Up to 8 Gpts of acquisition memory for detailed viewing of link training.

Read More about the WaveMaster 8000HD capabilities for USB testing.

Explore More about Teledyne LeCroy USB and Thunderbolt Protocol Analyzers and Exercisers.

QualiPHY 2 automated compliance software for USB4 transmitter (Tx), receiver (Rx) and return loss testing

Best USB Compliance Test Integration and Automation

QualiPHY 2 automated test framework provides validation and compliance in a fraction of the time.
  • Unified Tx, Rx, and Return Loss test framework for all compliance testing
  • Simplified test interface that is easy to understand and operate.
  • Compliance on time from anywhere with offline data processing using QPHY2-PC

Explore More about serial data validation and compliance software.

USB-C link testing with cross-layer analysis and PHY-logic debug using Teledyne LeCroy oscilloscope, protocol analyzer, CrossSync PHY software, and USB test coupon fixtures for cross-layer analysis

Unmatched USB-C Link Testing with Cross-Layer Analysis and PHY-logic Interoperability Debug

Seamlessly merge a protocol analyzer and an oscilloscope and view live link PHY-Logic operation.
  • Validate and debug Thunderbolt and USB Type-C active link operation
  • Quickly resolve interoperability issues by capturing the entire protocol stack
  • Analyze link training with integrated physical and protocol views

Read More about Cross-Layer Analysis.

Read More about PHY-Logic Debug.

An All-In-One Oscilloscope for All USB-C Compliance and Debug Testing

The WaveMaster 8000HD oscilloscope combines high-speed and sideband testing into a single test oscilloscope, making it the only oscilloscope that performs both PHY compliance and interoperability debug. It gives you the power to go beyond USB Type-C compliance to and achieve zero interoperability failures.

The WaveMaster 8000HD oscilloscope with callouts supporting its application in USB Type-C high-speed testing and USB-C sideband  testing

Best USB-C Electrical Compliance Test Integration and Automation

Teledyne LeCroy’s QualiPHY 2 automated test framework is a single unified test framwork for all Tx, Rx and Return Loss testing and permits off-line analysis for more efficiency – validation and compliance in a fraction of the time.

USB electrical compliance testing performed in a lab using QualiPHY 2 automated compliance test software and a WaveMaster 8250HD oscilloscope

Unified Tx, Rx and Return Loss Compliance Test Framework

QualiPHY 2 is a single automation test framework for all Tx, Rx and Return Loss testing.
  • Tx and Rx testing in one test interface.
  • Oscilloscope can run all tests without using an external server.
  • Oscilloscope can perform both Tx and Rx calibration.

Explore More about QualiPHY 2.

QualiPHY 2 automated test framework showing simplied test interface for USB electrical compliance testing.

Simplified USB Compliance Test Interface

  • Single test tree view for all settings, test selections and pass/fail test results.
  • Pop-up connection diagrams always accessible in test tree.
  • Easily retest or remove tests from database.
  • Test automation using powerful Python-enabled program control

Explore More about QualiPHY 2.

USB-C electrical and return loss compliance testing performed offline in an office using QPHY2-PC

Compliance On Time From Anywhere With Offline USB Test Analysis

Be more efficient and complete testing faster using QPHY2-PC
  • QPHY2-PC processes waveform data offline and frees the oscilloscope for other testing
  • More efficient use of lab resources – optimize oscilloscope usage
  • Complete testing faster – share test session across multiple labs and locations

Explore More about QPHY2-PC.

Unmatched USB-C Link Testing: CrossSync™ PHY Cross-Layer Analysis

CrossSync PHY seamlessly merges a protocol analyzer and oscilloscope. CrossSync PHY for USB enables USB4 and Thunderbolt waveforms from Teledyne LeCroy oscilloscopes to be viewed alongside Teledyne LeCroy M4x Protocol Analyzer traces, with complete time correlation of electrical and protocol information for easy and powerful validation and root-cause analysis.

USB-C interoperability testing showing cross-layer analysis using a Teledyne LeCroy oscilloscope, protocol analyzer, CrossSync PHY software, and USB test coupon fixtures
Block diagram of USB-C interoperability testing using a Teledyne LeCroy oscilloscope, protocol analyzer, CrossSync PHY software, and USB test coupon fixtures for cross-layer analysis
Block diagram of USB-C interoperability testing using a Teledyne LeCroy oscilloscope, protocol analyzer, CrossSync PHY software, and USB test coupon fixtures for cross-layer analysis
Screen image with callouts showing USB high-speed main link signals simultaneously analyzed using an oscilloscope and a protocol analyzer
Typical USB-C host system block diagram
Protocol trigger on USB4 CL1/CL2 low power state entry and exit with simultaneous protocol and electrical views using Teledyne LeCroy CrossSync PHY
White paper download image for “Your USB4 and DisplayPort Designs Will Fail Unless You Understand Link Training”

All certified USB and DisplayPort hardware is tested for standards compliance. However, compliance testing by itself cannot discover or eliminate all interoperability failure modes. Field interoperability issues lead to field failures and customer dissatisfaction. The figure above shows an interoperability test setup:

  • USB protocol analyzer (Teledyne LeCroy Voyager M4x shown)
  • High-bandwidth oscilloscope (Teledyne LeCroy WaveMaster®/SDA 8000HD Series shown)
  • Cross-layer analysis software (Teledyne LeCroy CrossSync™ PHY shown, running on the oscilloscope’s internal PC)
  • USB-C test coupon fixture (Teledyne LeCroy TF-USB-C-HS shown)
  • Low-speed (sideband) serial data triggers and decoders (running on the Teledyne LeCroy WaveMaster/SDA 8000HD Series Oscilloscope)

The TF-USB-C-HS Test Coupon Fixture permits simultaneous and transparent probing of both the electrical physical layer signals (going to the oscilloscope) and the protocol data traffic (going to the protocol analyzer) without disrupting the link, making live system debug possible.

  • The plug-to-receptacle design of the fixture simply extends the USB-C receptacle of the DUT with very low insertion loss and high return loss to maintain electrical signal transparency in a live system.
  • A short Low Loss eMarked C-C cable is used to connect to the link partner. The combined cable and fixture assembly provides equivalent insertion loss as a Thunderbolt 5 certified cable in the system for testing.
  • High-speed Tx/Rx electrical signals are acquired using Teledyne LeCroy’s DH Series Differential Probes connected to the oscilloscope.
  • Low-speed signals are accessed via 2.5 mm square pins that can be connected to the oscilloscope using either passive or active probes.
  • VBUS load current is measured using a current probe.
  • Data signals are input to the protocol analyzer with a user-provided USB4 cable.

Teledyne LeCroy provides both the oscilloscope for all high-speed PHY and low-speed sideband electrical signal capture and the protocol analyzer for protocol information capture.

  • Teledyne LeCroy WaveMaster 8000HD Series oscilloscope is a single test oscilloscope for all USB-C electrical signal capture.
  • Teledyne LeCroy USB protocol analyzers are the leading protocol analyzers for USB-C, Thunderbolt, and Power Delivery.

The CrossSync PHY software option for your Teledyne LeCroy oscilloscope enables precise, intuitive navigation between time-correlated USB protocol analyzer and oscilloscope traces.

  1. CrossSync PHY navigation bar makes clear the timing relationship between linked protocol analyzer and oscilloscope captures
  2. One or many oscilloscope acquisition segments are represented in the navigation bar
  3. Protocol analyzer trace represented in the navigation bar
  4. Common trigger point ensures precise timing alignment between protocol trace, oscilloscope acquisitions, and navigation bar view
  5. Oscilloscope timebase and protocol analyzer acquisition window remain synchronized while navigating through the combined acquisition, for total confidence in timing behavior
  6. Selecting a packet on the protocol trace enables zoom traces on the oscilloscope to the same time window, enabling sub-packet-level measurement precision

Explore More

USB’s host-device architecture and host designs often contain multiple receptacles and attach to almost every type of peripheral while supplying power in both directions. Retimers and long channels further complicate the design and interoperability debug.

  • Validate and debug Thunderbolt and USB Type-C active link operation by observing both high-speed electrical and protocol behaviors simultaneously without disturbing the link.
  • Quickly resolve interoperability issues by capturing the entire protocol stack, high-speed and low-speed sideband, electrical and protocol. Measure timing relationships between electrical and protocol domains.
  • Analyze link training by observing electrical-level results of protocol-level commands
  • Faster root-cause analysis gets products to market faster with advertised interoperability performance, leading to higher end-user customer satisfaction.

Coordinating device, host retimer and host SoC exits from USB4, USB 3.2 or system low power states is complex, especially for legacy devices designed before retimers were in common use. There is significant potential for the three link state machines to become misaligned, especially with USB 3.2 devices expecting to handshake directly with the host.

  • Protocol Analyzer is set to trigger on low power entry (e.g., CL1_ACK) — a complex trigger condition commonly supported by protocol analyzers but not by oscilloscopes, and the protocol analyzer cross-triggers the oscilloscope.
  • Oscilloscope then captures the electrical (physical layer) signals, including Low Frequency Periodic Signaling (LFPS) timings and the relative timings of device and host transmitter wake up.
  • CrossSync PHY software time-correlates and links the two information displays.

Download White Paper: Your USB4 and DisplayPort Designs Will Fail Unless You Understand Link Training

USB and DisplayPort product and test experts from Kandou and Teledyne LeCroy collaborated on this technical white paper. It explains in detail why your designs could fail interoperability and how you can debug the problem. Six common failures and debug scenarios are described in detail:

  • USB4
    • Entering and Exiting Low Power States
    • Legacy USB 3.2 Link Initialization Interoperability
    • Incorrect Flip Programming
    • Sideband Use (SBU) Glitch Issues
  • DisplayPort
    • Retimed Clock Frequency Variation
    • Compliance Pattern Issues

Download White Paper: Your USB4 and DisplayPort Designs Will Fail Unless You Understand Link Training

Unmatched USB-C Link Testing: PHY-Logic and Sideband Debug

Link training and sideband negotiation failures account for many compliance and interoperability failures found on USB Type-C connected devices. These failures can be quickly identified as either physical or link layer issues by using Teledyne LeCroy's Physical Layer Logical Sub-Block and Sideband debug solutions.

USB4 PHY-logic layer debug using Teledyne LeCroy equipment to simultaneously probe both USB4 high-speed and side-band signals
USB4 PHY-logic layer debug using Teledyne LeCroy equipment to simultaneously probe both USB4 high-speed and side-band signals
USB-C Test Coupon Fixtures provide connections to all USB Type-C High-speed PHY, Power Delivery and Sideband signals, including USB 2.0, USB-PD (Power Delivery), DP-AUX (DisplayPort AUX Channel) and USB4-SB (USB4 Sidebands).
The WaveMaster 8000HD triggers on the USB4 Preset change and captures the high-speed data lanes for further analysis
The WaveMaster 8000HD triggers on the USB4 Preset change and captures the high-speed data lanes for further analysis
USB 3.2 link initialization failure debugging using Teledyne LeCroy oscilloscope, test fixtures and software.
Simultaneous I2C, USB Power Delivery and USB4 SB decoding to debug and incorrect USB-C connector flip programming issue
White paper download image for “Your USB4 and DisplayPort Designs Will Fail Unless You Understand Link Training”

Teledyne LeCroy’s WaveMaster 8000HD oscilloscope can directly connect to low-cost probes (no adapter required) to support sideband signal probing. Test coupon fixtures provide ability to simultaneously probe high-speed and low-speed signals on live links. Triggers and decoders complete the solution.

An all-in-one oscilloscope and innovative test coupon fixtures provide ability to simultaneously probe, trigger, and analyze the high-speed and low-speed sideband signals on live links – something no other supplier can provide.

Teledyne LeCroy test coupon fixtures (shown in the diagram above) permit live link probing of all signals at the USB Type-C connector.

  • The TF-USB-C-SB USB4 Sideband Test Coupon Fixture provides sideband signal access (USB 2.0 D+/D-, CC1/CC2, VBUS, ILOAD, SBU1/SBU2 for USB4-SB and DisplayPort AUX, various ground signals).
  • The TF-USB-C-HS adds access to high-speed Tx/Rx signals (Tx1, Tx2, Rx1, Rx2) using DH Series Differential Probes.
  • A short low loss eMarked Cable is included, which when combined with the test coupon provides the equivalent loss as a certified Thunderbolt 5 cable, ensuring interoperability during debug.

The WaveMaster 8000HD oscilloscope triggers on a USB4 Preset change or other sideband message and then captures and decodes the sideband messages and other high-speed data lane traffic for further analysis.

See the whole link using USB CrossSync PHY.

ProtoSync is a software option for WaveMaster 8000HD oscilloscopes. It exports captured physical layer signals from the oscilloscope to (freely available) Teledyne LeCroy protocol analysis software. It allows the same protocol analysis views as a Teledyne LeCroy protocol analyzer but using the oscilloscope captured data, synchronized with the oscilloscope capture. It differs from CrossSync PHY in that protocol analyzer hardware is not required (and therefore there is no protocol signal triggering).

  • The USB 3.2 link is analyzed while data is transferred from the Host to the Link Partner.
  • An ACK occurs on Ch1 as data is transferred on Ch2.
  • Simply click on a decoded packet in the protocol view to zoom in on the corresponding electrical signal details.

USB 3.2 debugging can be more challenging than USB4 and DisplayPort because there is no low-speed sideband channel. Instead, link initialization is coordinated using LFPS transmitted on the high-speed lanes. Debugging such USB 3.2 initialization requires a time-aligned simultaneous capture of several hundred milliseconds of retimer power rails, reset pin and I2C communications, and USB 3.2 LFPS signals.

  • USB 3.2 initialization from an independently powered dock device has started transmitting LFPS (top yellow traces, full capture on the left, zoom on the right) before the retimer has been programmed (bottom magenta traces, full capture on the left, zoom on the right).
  • Zoomed traces (right) show that the retimer reset pin (driven by the USB PD controller GPIO) was low when the device started transmitting LFPS, which is unexpected behavior.
  • A complete view of the timing relationships between these signals is required to determine the PD firmware adjustments needed to solve USB 3.2 interoperability issues.

USB-C is a reversible connector. One engineering consequence of this is that the mapping of PCB traces and retimer pins to high-speed differential pairs depends on the connector orientation.

  • The traces carrying TX1 in the normal orientation carry TX2 when the connector is flipped. Retimers need to know the mapping in order to transport signals correctly between the host SoC and the USB-C receptacle.
  • Debugging a live USB link with the Teledyne LeCroy WaveMaster/SDA 8000HD Oscilloscope and the TF-USB-C-HS Test Coupon Fixture allows an engineer to monitor USB PD controller programming (I2C signals), CC signals, Sideband Use (SBU), and high-speed lanes simultaneously.

USB and DisplayPort product and test experts from Kandou and Teledyne LeCroy collaborated on this technical white paper. It explains in detail why your designs could fail interoperability and how you can debug the problem. Six common failures and debug scenarios are described in detail:

  • USB4
    • Entering and Exiting Low Power States
    • Legacy USB 3.2 Link Initialization Interoperability
    • Incorrect Flip Programming
    • Sideband Use (SBU) Glitch Issues
  • DisplayPort
    • Retimed Clock Frequency Variation
    • Compliance Pattern Issues

Download White Paper: Your USB4 and DisplayPort Designs Will Fail Unless You Understand Link Training

Best Integrated and Most Efficient USB4 and Thunderbolt Electrical Test with Unmatched Debug

Teledyne LeCroy provides one unified test framework (QualiPHY 2) that integrates and automates all equipment (oscilloscope, BERT, and network analyzer) for all Tx, Rx and Return Loss tests per the USB-IF USB4 Compliance Test Specification (CTS). When products don’t quickly pass compliance testing, Teledyne LeCroy helps you solve the problems faster with unmatched serial data electrical debug and cross-layer analysis.

QualiPHY 2 automated compliance software for USB4 transmitter (Tx), receiver (Rx) and return loss testing

Best Automated Compliance Test Integration of All Instruments

Complete test and reporting for all USB-IF required USB4 compliance tests.
  • One single unified control and automation test framework for the oscilloscope, BERT and network analyzer
  • Easier to use than multiple test frameworks from multiple vendors
  • Completes the validation faster - saves time

Explore More about QualiPHY 2 Compliance Test Framework.

Serial data validation and compliance testing performed offline in an office using QualiPHY 2

Increased Test Efficiency

Run Tx and Rx compliance testing separate from the oscilloscope
  • Utilizes QPHY2-PC to perform testing offline without connection to the oscilloscope or BERT
  • Increases the use of test equipment hardware for the most important functions – as data acquisition engines
  • Reduces total test time - bring products to market faster

Explore More about QPHY2-PC.

Block diagram of USB4  interoperability testing using a Teledyne LeCroy oscilloscope, protocol analyzer, CrossSync PHY software, and USB test coupon fixtures for cross-layer analysis

Unmatched Compliance and Link Debug

Teledyne LeCroy helps you quickly resolve problems when the occur
  • Debug compliance failures with USB4-specific Serial Data Expert tools.
  • Debug basic interoperability issues more effectively with sideband message triggers, decoders, and other tools.
  • Debug complex interoperability issues by seeing the whole link – electrical and protocol – in operation on live links.

Read More about Cross-Layer Analysis and PHY-Logic Debug.

Simple and Accurate USB4 Return Loss Compliance Measurements

USB-IF Required USB4 Tx/Rx Test Cable De-Embed, Tx/Rx Return Loss and Rx Channel Measurements

Teledyne LeCroy’s QPHY2-USB4-TX-RX automated compliance test software supports the following required return loss and S-parameter compliance test measurements:

    USB4 return loss testing using a Teledyne LeCroy WavePulser 40iX network analyzer, QualiPHY 2 compliance test software, and a Teledyne LeCroy oscilloscope.

    USB 3.2, USB 3.1 and USB 3.0 Compliance Test, Validation and Debug

    USB 3.2, USB 3.1 and USB 3.0 testing to USB-IF Gold Suite standards

    USB 3.2 transmitter testing using Teledyne LeCroy WaveMaster 8000HD oscilloscope and QualiPHY compliance test software

    Fast and Easy Transmitter Testing and Debug

    USB 3.2 compliance testing to “Gold Suite” levels
    USB 3.2 receiver testing using Anritsu MP1900A BERT and Teledyne LeCroy QualiPHY compliance software

    Receiver Testing Using Industry-Standard Anritsu MP1900A BERT

    Fully-automated Rx stressed signal calibration and receiver BER testing
    • Single compliance test framework for all Tx and Rx tests
    • Anritsu MP1900A fully integrated into QualiPHY automated compliance test framework
    • Automated short and long-channel calibration using oscilloscope, BERT and USB-IF compliance fixtures
    • USB-IF compliance test report for all tests
    USB 3.2 link debug using Teledyne LeCroy oscilloscope trigger, decode and other software tools

    Type-C Sideband, Alt Mode and PHY-logic debug

    Teledyne LeCroy provides unique capabilities for Power Delivery, Alt Mode, and USB PHY-logic testing

    Read More: Cross-Layer Analysis

    Built-In USB-C Test Expertise Provided in Serial Data Analysis (SDA) Expert

    Teledyne LeCroy builds decades of industry standard expertise into SDA Expert (SDAX) serial data analysis software and options. Simply select the standard, configure the test point, and select measurements.

    Select USB Standard in SDA Expert

    Simply select the USB serial standard from a pre-defined list and gain instant test expertise for measuring and characterizing USB signals. Available with USB technology options for SDA Expert.

    • Easily configurable test point setup
    • Comprehensive Eye, Jitter, and other USB-C PHY measurements
    • Simple, powerful equalization analysis
    Explore More

    Configure USB Test Point

    Test Point Configuration lets you perform transmitter testing at any test point in the link. The dynamic test point diagram changes based on your selection, in order to reduce setup errors.

    • Test at the ‘PHY Si’ test point by using a measured S-parameter file to de-embed back to the transmitter pins
    • Select TP2 and connector type to test at the device connector
    • Select TP4_EQ to embed the standard’s cable model and apply equalization

    Use the WavePulser 40iX to create S-parameter files for embedding, de-embedding, and channel emulation for serial data analysis.

    Explore More

    Select USB Measurements

    USB-C technology specific measurements defined in the USB4, Thunderbolt, USB 3.2, and DisplayPort CTS (compliance test specifications) are accessible at a touch of a button in SDA Expert software.

    • USB Transmitter Equalization (TxEq, TX-FFE) measurements
    • USB Eye Testing - Eye Height, Eye Width, Eye Mask Testing
    • Amplitude – ACCM (AC Common mode), Pk-Pk Voltage, SNDR
    • Jitter – RJ (Random Jitter), DJ (Deterministic Jitter), TJ (Total Jitter), UJ (Uncorrelated Jitter), UDJ (Uncorrelated Deterministic Jitter), OEJ (Odd-Even Jitter)
    • SSC (Spread Spectrum Clock) – SSC Frequency Variation, SSC Rate, SSC Range
    Explore More

    USB 2.0 Electrical PHY Test Suite and Debug Tools

    The USB 2.0 standard consists of Low Speed (LS – 1.5Mb/s), Full Speed (FS – 12Mb/s), and High Speed (HS – 480Mb/s). Teledyne LeCroy supports tests for all speeds.

    USB 2.0 oscilloscope trigger and decode used with Teledyne LeCroy ProtoSync software option to show a simultaneous electrical signal and protocol view
    USB 2.0, USB2, USB2.0 High-speed test packet on WavePro High Definition Oscilloscope
    TF-USB-C-SB USB4 Sideband Test Coupon Fixture provides connections to all USB Type-C Power Delivery and Sideband signals, including USB 2.0, USB-PD (Power Delivery), DP-AUX (DisplayPort AUX Channel) and USB4-SB (USB4 Sidebands).
    USB 2.0 decode on an oscilloscope with protocol decode table and live link probing test coupon fixture from Teledyne LeCroy
    WavePro High Definition Oscilloscope for USB2 Compliance, USB2.0, USB 2.0 Compliance
    Teledyne LeCroy USB 3.2 and USB 2.0 protocol analyzers

    Teledyne LeCroy provides the oscilloscopes, automated compliance test software, active probes, and protocol layer tools for host, device and hub USB 2.0 electrical compliance and debug testing, whether implemented standalone or as part of a USB-C connector.

    • QPHY-USB automated compliance test software.
    • Live link probing with the TF-USB-C-SB Test Coupon Fixture and active differential probes compatible with coupon fixtures for complete compliance and live-link signal probing and acquisitions.
    • A full range of protocol decoders, protocol analysis software, and protocol analyzers.
    • Full range of oscilloscope bandwidths to support basic USB 2.0 compliance through all USB-C testing.

    QPHY-USB test software implements a full set of USB-IF approved electrical tests for USB 2.0, including High-, Full-, and Low-speed tests.

    • Support for host, device, and hub testing.
    • Simple and easy-to-use automated testing.
    • Available TF-USB-B test fixture.

    Watch Video: Is the USB You Designed Perfect? This is How You Test It.

    Teledyne LeCroy test coupon fixtures permit live link probing of all signals at the USB Type-C connector.

    Teledyne LeCroy offers a rich set of triggers and protocol decoders to debug interoperability failures using oscilloscope.

    • USB 2.0 TDME – Trigger, Decode Measurements, and Eye Diagram software.
    • HSIC D – High-speed Inter-Chip decode software for oscilloscopes.
    • USB 2.0 ProtoSync – Protocol analyzer software for a more detailed view of protocol traffic using the oscilloscope acquisition data.
    • Access USB 2.0 D+/D- live signal traffic using TF-USB-C-SB Sideband Test Coupon Fixtures.

    Read More about Trigger, Decode, Measure/Graph and Eye Diagram Debugging Options.

    Recommended Teledyne LeCroy oscilloscope models for USB 2.0 testing:

    • WaveMaster 8000HD high-bandwidth oscilloscopes for USB-C and all USB-C testing (USB4, USB 3.2, USB 2.0, Thunderbolt, and DisplayPort) – a single test oscilloscope for all low-speed and high-speed signals.
    • WavePro HD oscilloscopes with up to 8 GHz of bandwidth for USB 2.0 compliance and USB-C sideband testing.

    Recommended Teledyne LeCroy protocol analyzers for USB 2.0 testing:

    • Advisor T3 – portable, affordable USB analyzer for USB 2.0 and USB 3.2.
    • Mercury T2P/T2C – pocket-sized USB Type-C and Power Delivery analyzer for USB 2.0, Power Delivery 3.2, SBU, and DP AUX.
    • Mercury T2 classic USB analyzer for USB 2.0.

    Explore More about Teledyne LeCroy USB protocol analyzers and exercisers.

    USB Type-C Power Delivery (USB PD) Electrical Test and Protocol Analysis

    Only Teledyne LeCroy supplies the full range of solutions for USB Power Delivery

    USB-PD BMC (biphase mark coded) physical layer signal capture with decode and eye diagram mask testing
    TF-USB-C-SB USB4 Sideband Test Coupon Fixture provides connections to all USB Type-C Power Delivery and Sideband signals, including USB 2.0, USB-PD (Power Delivery), DP-AUX (DisplayPort AUX Channel) and USB4-SB (USB4 Sidebands).
    USB Power Delivery serial data signal captured and decoded by an oscilloscope with correlation of PS_RDY value to separately probe power rail analog signal.
    DisplayPort AUX channel decode showing zoom trace and protocol table with details
    Mercury_t2c_t2p

    USB Power Delivery (PD) signals are an integral part of the USB Type-C interface. Proper correlation between PD events and other USB-C low-speed and high-speed signals must be established to ensure interoperability. Teledyne LeCroy supplies the full range of equipment for interoperability testing, from electrical test and debug to protocol compliance.

    • Test coupon fixtures for live-link signal probing and acquisitions.
    • Oscilloscope-based triggers, decoders, and more for USB PD, USB Type-C Alt Mode, and DP AUX.
    • Protocol analyzers for USB PD and USB Type-C compliance.

    USB PD TDMP (USB Power Delivery Trigger, Decode, Measure/Graph, Physical Layer Measurements) is the most comprehensive oscilloscope-based USB Power Delivery test solution. It enables USB Power Delivery power-supply validation and debug by correlating CC, VBUS, and ILOAD signals. Time-correlate USB PD with other USB Type-C connector protocols.

    • Access CC1/CC2, VBUS, and ILOAD using the TF-USB-C-SB debug coupon.
    • Trigger on PD preamble, ordered sets, messages, and errors.
    • Decode SPR and EPR PD messages, Power Delivery Objects (PDOs), and more.
    • Measure/Graph electrical voltage, current, and timing parameters.
    • Physical Layer BMC eye mask testing and measurements.

    DP-AUX TDMP (DisplayPort AUX Trigger, Decode, Measure/Graph, Physical Layer Measurements) is the most comprehensive oscilloscope-based DisplayPort AUX Channel test solution. It supports DisplayPort 2.0/1.4 and embedded DisplayPort (eDP) standards.

    • Trigger and decode DisplayPort AUX reads/writes (native or I²C).
    • DisplayPort AUX eye diagram PHY compliance testing.
    • USB Type-C system-level debug simultaneously with Main Link or USB Power Delivery.

    Teledyne LeCroy provides protocol analyzers, exercisers, and generators for DisplayPort AUX channel and DisplayPort main links.

    DisplayPort Test Solutions for Test Labs and Developers

    VESA defines the DisplayPort PHY compliance test specification (CTS). The latest DisplayPort 2.1 version supersedes the legacy DisplayPort 1.4b and significantly increases data rates, creating more design challenges, PHY compliance test time, and likelihood of interoperability failures. Teledyne LeCroy DisplayPort 2.1 test solutions provide:

    • PHY compliance source testing
    • PHY compliance sink testing
    • Interoperability validation with combined PHY and protocol debug

    Explore More about DisplayPort PHY Test and Interoperability Testing.

    USB-C High-speed Testing Compare – Teledyne LeCroy, Keysight, Tektronix

    Teledyne LeCroy oscilloscopes performance, features, and capabilities make them the ideal oscilloscope four USB-C testing Select the right Teledyne LeCroy oscilloscope for your USB-C testing. Compare to Keysight oscilloscopes and Tektronix oscilloscopes.

    USB-C High-speed
    Oscilloscope Features
    Required 25 GHz Bandwidth
    Required 80GS/s Sample Rate
    Resolution
    Max Record Length
    High-speed Inputs (50 Ohm)
    Sideband Inputs (1M Ohm)
    Sideband Triggers
    High-speed Data Bus Decoders
    Protocol Analysis on Oscilloscope Data
    Sideband Triggers and Decoders
    Sideband PHY Measurements
    Sideband MSO Trigger & Decode
    Built in USB-C technology options
    PHY Tx (Source) Compliance Software
    PHY Rx (Sink) Compliance Software
    USB4 and Thunderbolt
    USB 3.2
    DisplayPort 2.1/1.4
    PHY-Logic Layer Test Fixture
    Cross-layer Analysis
    Front Panel SuperSpeed USB Ports
    Teledyne LeCroy
    WaveMaster 8000HD
    12 bits
    8 Gpts
    (ProtoSync)
    Using MP1900A
    Yes
    Yes
    Yes
    TF-USB-C-HS Test Coupon Fixture
    (CrossSync PHY)
    Keysight
    UXR Series
    10 bits
    2 Gpts
    ---
    ---
    ---
    ---
    Decode Only
    ---
    ---
    ---
    Using JBERT
    Yes
    Yes
    Yes
    Active Link Fixture
    ---
    ---
    Tektronix
    DPO70000SX Series
    8 bits
    500 Mpts
    ---
    ---
    ---
    ---
    ---
    ---
    ---
    ---
    Using MP1900A
    Yes
    No
    No
    ---
    ---
    ---

    USB-C Compliance Test Experience, Leadership, Support

    The Teledyne LeCroy WaveMaster 8000HD Oscilloscope, the Anritsu SQA-R MP1900A BERT, and the Teledyne LeCroy WavePulser 40iX Interconnect (Network) Analyzer with QualiPHY 2 automated compliance test software results in the most powerful characterization, compliance and debug solution available. First-line support for the solution is available from the industry’s most experienced USB-C field support team at Teledyne LeCroy.

    WaveMaster 8000HD oscilloscope performing USB4 PHY electrical compliance test.
    Anritsu MP1900A for USB-C receiver calibration and BER testing
    USB-IF USB4 return loss and Rx channel measurements made by a WavePulser 40iX network analyzer
    QualiPHY 2 automated compliance software for USB4 transmitter (Tx), receiver (Rx) and return loss testing

    WaveMaster 8000HD oscilloscopes support all generations of USB and DisplayPort Tx/Rx testing at all required bandwidths:

    • 25 GHz for USB4, Thunderbolt, and DisplayPort UHBR.
    • 16 GHz for USB 3.2 (Gen2) and DisplayPort HBR3.
    • 13 GHz for USB 3.2 (Gen1) and DisplayPort RBR/HBR/HBR2.
    • All models support USB 2.0.

    The Anritsu SQA-R MP1900A Signal Quality Analyzer is a high-speed BERT solution in one box. With time and temperature jitter drift of less than ±2% (2 days, ±5°C), the MP1900A provides exceptional signal quality for highly repeatable results. It combines:

    • Jitter and noise generation for all Sink and Rx calibration and BER testing.
    • High-quality waveform PPG with integrated 10-tap emphasis.
    • LTSSM loopback and error detector with variable CTLE for USB 3.2 Rx testing.

    Watch Video on Anritsu USB4 v2 Calibration Demonstration Guide.

    The WavePulser 40iX Interconnect Analyzer performs network analysis S-parameter measurements for USB-IF required return loss and Rx channel measurements.

    • Tx/Rx Test Cable De-Embed.
    • Tx/Rx Return Loss.
    • Rx Channel Measurements.

    Explore More about WavePulser 40iX Interconnect Analyzer.

    QualiPHY 2 software Options: QPHY2-USB4-TX-RX , QPHY-USB3.2-TXRX , QPHY-USB (2.0) , QPHY2-DP2-SOURCE-TX , and QPHY2-DP2-SINK-RX . fully automate all aspects of USB-C PHY Tx, Rx, and Return Loss compliance testing. Teledyne LeCroy provides full application support for all USB integrated electrical compliance test solutions.

    • Transmitter (Source) Testing and Receiver (Sink) Compliance Testing.
    • Return Loss Compliance Testing.
    • Sideband (USB4-SB and DP-AUX) Compliance Testing.
    • Report Generation.

    Explore More about QualiPHY automated compliance test software.

    USB-C Sideband Testing Compare – Teledyne LeCroy, Keysight, Tektronix

    Teledyne LeCroy oscilloscopes performance, features, and capabilities make them the ideal oscilloscope four USB-C testing Select the right Teledyne LeCroy oscilloscope for your USB-C testing. Compare to Keysight oscilloscopes and Tektronix oscilloscopes.

    USB-C High-speed
    Oscilloscope Features
    Bandwidth
    Resolution
    Max Sample Rate
    Max Record Length
    Sideband Triggers
    Data Bus Decoder

    USB 3.2 (Gen1)
    USB 2.0
    Sideband MSO Trigger & Decode
    USB 2.0 Compliance Software
    Sideband PHY-Logic Capabilities
    PHY-Logic Test Coupon
    Protocol Analysis on Oscilloscope Data
    USB 2.0 and USB 3.2 (Gen1)
    Keysight
    MXR Series
    2 – 6 GHz
    10 bits
    16 GS/s
    1.6 Gpts
     
    --
    ---
    Trigger Decode
    Active Link Fixture
    ---
    Tektronix
    6 Series
    2 – 6 GHz
    12-bit ADC
    12-bit ADC
    1 Gpt
    ---
     
    --
    --
    ---
    ---
    ---
    ---

    Resources

    DOCUMENT NAME
    Data Sheet – USB Test Solutions

    All-In-One Solution for USB and USB-C® Electrical Test Compliance and Debug

    Datasheet
    Data Sheet – USB4 Solutions

    The complete range of electrical and combined electrical+protocol test validation, compliance, and debug for USB4.

    Datasheet
    Data Sheet – USB 3.2 PHY Test Solution

    Since becoming the first USB-IF "Gold Suite" in 2011, Teledyne LeCroy continues to be the trusted leader in all the latest USB Type-C technologies including USB 3.2. Teledyne Lecroy goes beyond compliance to provide the deepest signal integrity and cross layer (protocol/electrical) toolbox for system level debug available.

    Datasheet
    Data Sheet – USB 2.0 Compliance Testing

    The USB package provides a complete acquisition and analysis system for USB 2.0 devices, hosts, and hubs, as specified in the USB-IF USB 2.0 Electrical Test Specification.

    Datasheet
    TF-USB-C Test Coupon Fixtures

    PHY logic layer and sideband negotiation issues account for many compliance and interoperability failures in USB Type-C connected devices. These failures can be quickly debugged using unmatched PHY-logic layer and sideband debug solutions on a wide range of oscilloscopes

    Datasheet
    USB CrossSync PHY

    Interoperability issues can lead to finger-pointing exercises that cost money and time-to-market. Teledyne LeCroy CrossSync PHY software merges the functions of your Teledyne LeCroy protocol analyzer and oscilloscope - giving insight into link behavior that no other instrument can provide.

    Datasheet
    Data Sheet – USB4 Decode, Measure, Eye (DME)

    USB4bus DME (Decode, Measure/Graph, and Eye Diagram) software
    provides eye diagram measurements recovering the clock on decoded
    symbols. Evaluate high-speed signal quality during link training as the transmitter sends SLOS (Symbol Lock Ordered Sets) to the receiver during link training.

    Datasheet
    Data Sheet – USB 3.2 Decode

    The USB 3.2 decode option for Teledyne LeCroy oscilloscopes provides link layer decode information annotated on the USB 3.2 physical layer waveforms. This provides the ability to view protocol traffic on the oscilloscope and verify that the link is alive and transmitting properly.

    Datasheet
    Data Sheet – USB-C (USB 2.0, USB-PD, DP-AUX, USB4-SB) TDMP

    Teledyne LeCroy’s Trigger (T), Decode (D), Measure/Graph (M or G) and Eye Diagram and Physical Layer (E or P) options are the best in the industry and nearly universally available across the entire Teledyne LeCroy oscilloscope product line

    Datasheet
    Data Sheet – ProtoSync

    The USB 3.2 decode option for Teledyne LeCroy oscilloscopes provides link layer decode information annotated on the USB 3.2 physical layer waveforms. This provides the ability to view protocol traffic on the oscilloscope and verify that the link is alive and transmitting properly.

    Datasheet
    Your USB4 and DisplayPort Designs Will Fail Unless You Understand Link Training

    Complex USB4 and DisplayPort 2.1 protocol, electrical and signal integrity issues can manifest themselves in difficult-to-solve link problems, requiring new approaches to testing and debug to ensure high quality and reliable products. Download the White Paper to learn more.

    Download
    USB 3.2 Debug using the TF-USB-C-HS Fixture

    This guide covers how to debug USB 3.2 systems using the TF-USB-C-SH test coupon fixture, DH-PX series differential probes, R4060 Rail Probe, CP031A current probe, and USB32busD decode and Protosync software on the WaveMaster/SDA800 HD oscilloscope.

    Download
    USB 2.0 Compliance and Debug Reference Guide

    This guide provides detailed setups and expected results for USB 2.0 device compliance testing using QPHY-USB (USB 2.0 Compliance) test software as well as debugging USB 2.0 protocol failures using USB2bus TDMP software.

    Download
    USB 2.0 Debug using the TF-USB-C-SB Fixture

    This guide covers how to debug USB 2.0 systems using the TF-USB-C-SB test coupon fixture, ZD1500 differential probe, CP031A current probe, and USB2busD USB 2.0 bus decode software on Teledyne LeCroy HD oscilloscopes of all bandwidths.

    Download
    Power Delivery Debug using the TF-USB-C-SB Fixture

    This guide covers how to debug USB Power Delivery using the TF-USB-C-SB test coupon fixture, passive probes, CP031A current probe, and USB-PD TDMP Power Delivery Trigger, Decode, measure/graph, and physical layer test software on Teledyne LeCroy HD oscilloscopes of all bandwidths. USB Power Delivery Compliance debug is performed by adding M310e Power Delivery Analyzer.

    Download

    Serial data electrical/PHY validation can be complex, time-consuming and costly. This webinar will present best practices and the latest automated test methods for high-speed serial SerDes Tx, Rx, and return loss compliance and validation.

    USB 2.0 is a common serial data and power delivery standard which is integrated into many new electrical designs. Join Teledyne LeCroy to learn new methods and measurement techniques for rapid debugging of USB 2.0 electrical issues.

    USB Type-C® Technologies PHY Testing Webinar Series

    Join Teledyne LeCroy for our webinar series on USB Type-C technologies with a focus on the physical layer, from an introduction to the various technologies in the Type-C ecosystem to USB 3.2, USB4™, Thunderbolt™, DisplayPort™, USB4 Type-C sideband (USB Power Delivery, DisplayPort AUX, USB4 SB) testing.

    Register for all

    Part 1 - Part 1 Introduction to USB Type-C® Technologies Physical Layer Testing

    The USB Type-C connector is quickly becoming the PC industry’s standard for converged high-speed data, display (video) and power delivery. In this session we will provide an overview of all the electrical signals sent over the USB Type-C connector and how to test them.

    Part 2 – USB 3.2 Physical Layer Compliance Test Overview

    In this session we focus on the USB 3.2 specification given its ubiquitous use for USB peripherals. We will cover new test requirements for the USB 3.2 CTS and the tools for testing it.

    Part 3 – USB4® Version 1.0 and Thunderbolt Physical Layer Compliance Testing

    In this session we will provide an update of the latest tools available for USB4 electrical validation and compliance testing and requirements to adhere to the USB-IF’s test program.

    Part 4 – How to Debug USB4™ and USB 3.2 PHY-logic and Sideband Links

    In this session we will focus on compliance and interoperability (C&I) of USB Type-C connected hosts, hubs, adapters, and peripherals, with practical approaches to debugging electrical system issues that may occur when connecting USB-C devices together and meeting all USB-IF and Thunderbolt Specifications

    Part 5 - How to Perform DisplayPort™ 2 Physical Layer Compliance Testing and Debug

    In this session we review the latest PHY test requirements DisplayPort 2. Source and Sink test updates and new VESA compliance program requirements.

    Part 6 – USB4® Version 2.0 Tx/Rx Physical Layer Compliance Testing

    Join Teledyne LeCroy as we provide an update on USB4® Version 2.0 electrical validation and compliance testing, the latest tools available, and challenges you might encounter in meeting the timelines of the USB-IF test program.

     
    QPHY2-USB4-TX-RX Overview
     
    USB4-SB Triggering
     
    USB CrossSync PHY
     
    USB-C Test Coupon Fixtures
     
    USB Type-C Sideband Testing
     
    USB4 Transmitter Compliance
     
    USB4 Receiver Compliance
     
    USB4 S-parameter Measurements
     
    USB 3.2 PHY and PHY-Logic Testing
     
    USB 3.2 Transmitter Compliance
     
    USB 3.2 Receiver Compliance
     
    USB 3.2 PHY-Logic Debug
     
    USB Power Delivery Measurements
     
    DisplayPort Alt Mode Debug

    Need Assistance or Information?

    Please fill out this form and let us know whether you want to Sign Up for Updates, be Contacted by Sales, or would like to Request a Demo
    USB Type-C®, and USB-C®, USB4® are trademarks of the USB Implementers Forum (USB-IF) and are intended for use with products based on and compliant with USB Type-C cable and connector specification. DisplayPort™ is a trademark of Video Electronics Standards Association (VESA). Thunderbolt™ is a trademark of Intel Corporation.