USB and USB-C® Electrical Test and Interoperability
Cross-Layer Debug Solutions
USB Compliance Is Only The Start – Teledyne LeCroy Helps You
Find
Why Real USB-C
Links Fail
USB-C has become the universal converged interface for data, display, power, and
sideband control. Higher speeds in USB4 require more testing on more lanes, and the
convergence makes compliance and interoperability failures harder to find,
reproduce, and fix. Engineers need:
- Faster automated pre-compliance and compliance testing
- Offline compliance test analysis to reduce lab bottlenecks
- Synchronized PHY, protocol, and sideband visibility to find the root cause of
interoperability failures on real links that have passed compliance
Engineers need to complete an extensive range of compliance tests quickly,
accurately, and repeatedly.
- USB compliance test to USB-IF standards requires a comprehensive range
of transmitter, receiver, sideband, power delivery, repeater,
cable/connector and return loss tests.
- Newer, higher-speed USB standards (e.g., USB4) add more lanes at higher
speeds and more tests to the compliance test specification (CTS),
creating test bottlenecks
- Setup complexity and human error impact test efficiency and test
quality,
especially when test procedures change.
- PHY compliance test alone is not sufficient to understand real-world USB
system performance
Products may pass compliance but still fail in a real USB ecosystem due to
poor synchronization between electrical
(high-speed PHY), sideband and protocol behaviors during link negotiation
and active operation. This results in
end-user dissatisfaction with real-world performance.
-
Formal USB-IF CTS success can still result in compliance tested products
failing in real-world links.
- Higher-speed USB links and long channels require the use of linear
redrivers, retimers and LTTPRs, increasing
design complexity and the likelihood of link training failures.
- Cross-layer failure ambiguity results in difficult to debug failures
because failures could be
electrical/PHY-related, protocol/logic-related, or a combination of both
PHY and logic (common during sideband
negotiations).
- Interoperability failures are economically painful because they impact
the end-user and are organizationally
difficult to source and resolve.
Testing converged USB-C links and/or higher-speed USB4 links is
fundamentally different than testing USB 3.2 and previous USB interfaces.
Products can pass formal PHY compliance and still fail during link training,
sideband negotiation, or real-world interoperability.
- Tx, Rx and Return Loss compliance needs to be better integrated and
completely automated to reduce the increased knowledge burden on the
test engineers.
- Pre-compliance and compliance testing needs to be faster and more
efficient due to the increased test requirements - compliance test data
processing needs to be moved from the acquisition engine (oscilloscope)
to a separate PC.
- The oscilloscope needs to be focused on debugging Interoperability
failures that result in end-user dissatisfaction – a compliance “pass”
does not guarantee proper interoperability with today’s high-speed USB4
links and long channels
Teledyne LeCroy is uniquely positioned to provide fast, efficient compliance
testing, the most capable high-speed serial link debug when compliance
failures occur, and unique cross-layer debug tools to debug PHY-logic
interoperability problems on live links.
- The WaveMaster® 8000HD oscilloscope is the best oscilloscope for low and
high-speed USB-C testing. It combines high-speed and sideband testing
into a single test oscilloscope – the only oscilloscope with these
capabilities.
- QualiPHY 2 automated compliance test framework provides validation and
compliance in a fraction of the time and QPHY2-PC permits more efficient
offline testing and completes compliance testing faster.
- Unmatched USB-C link testing with cross-layer analysis on live links for
better interoperability debug
An All-In-One Oscilloscope for All USB-C Compliance and
Debug Testing
The WaveMaster 8000HD oscilloscope combines high-speed and
sideband testing into a single instrument.
- Four 25 GHz, 80 GS/s inputs with 12-bit resolution for multi-lane
compliance testing.
- Four 2 GHz, 1 MΩ-compatible input channels for sideband signal
probing.
- Up to 8 Gpts of acquisition memory for detailed viewing of link
training.
Read More
about the WaveMaster 8000HD capabilities for USB testing.
Explore More
about Teledyne LeCroy USB and Thunderbolt Protocol Analyzers and Exercisers.
Best USB Compliance Test Integration and Automation
QualiPHY 2 automated test framework provides validation and
compliance in a fraction of the time.
- Unified Tx, Rx, and Return Loss test framework for all compliance
testing
- Simplified test interface that is easy to understand and operate.
- Compliance on time from anywhere with offline data processing using
QPHY2-PC
Explore More
about serial data validation and compliance software.
Unmatched USB-C Link Testing with Cross-Layer Analysis
and PHY-logic Interoperability Debug
Seamlessly merge a protocol analyzer and an oscilloscope and
view live link PHY-Logic operation.
- Validate and debug Thunderbolt and USB Type-C active link operation
- Quickly resolve interoperability issues by capturing the entire protocol
stack
- Analyze link training with integrated physical and protocol views
Read More
about Cross-Layer Analysis.
Read More
about PHY-Logic Debug.
Unified Tx, Rx and Return Loss Compliance Test Framework
QualiPHY 2 is a single automation test framework for all Tx,
Rx and Return Loss testing.
- Tx and Rx testing in one test interface.
- Oscilloscope can run all tests without using an external server.
- Oscilloscope can perform both Tx and Rx calibration.
Explore More
about QualiPHY 2.
Simplified USB Compliance Test Interface
- Single test tree view for all settings, test selections and pass/fail
test results.
- Pop-up connection diagrams always accessible in test tree.
- Easily retest or remove tests from database.
- Test automation using powerful Python-enabled program control
Explore More
about QualiPHY 2.
Compliance On Time From Anywhere With Offline USB Test
Analysis
Be more efficient and complete testing faster using QPHY2-PC
- QPHY2-PC processes waveform data offline and frees the oscilloscope for
other testing
- More efficient use of lab resources – optimize oscilloscope usage
- Complete testing faster – share test session across multiple labs and
locations
Explore More
about QPHY2-PC.
All certified USB and DisplayPort hardware is tested for standards
compliance. However, compliance testing by itself cannot discover or
eliminate all interoperability failure modes. Field interoperability issues
lead to field failures and customer dissatisfaction. The figure above shows
an interoperability test setup:
- USB protocol analyzer (Teledyne LeCroy Voyager M4x shown)
- High-bandwidth oscilloscope (Teledyne LeCroy WaveMaster®/SDA 8000HD
Series shown)
- Cross-layer analysis software (Teledyne LeCroy CrossSync™ PHY shown,
running on the oscilloscope’s internal PC)
- USB-C test coupon fixture (Teledyne LeCroy TF-USB-C-HS shown)
- Low-speed (sideband) serial data triggers and decoders (running on the
Teledyne LeCroy WaveMaster/SDA 8000HD Series Oscilloscope)
The TF-USB-C-HS Test Coupon
Fixture permits simultaneous and transparent probing of both the
electrical physical layer signals (going to the oscilloscope) and the
protocol data traffic (going to the protocol analyzer) without disrupting
the link, making live system debug possible.
-
The plug-to-receptacle design of the fixture simply extends the
USB-C receptacle of the DUT with very low insertion loss and high
return loss to maintain electrical signal transparency in a live
system.
-
A short Low Loss eMarked C-C cable is used to connect to the link
partner. The combined cable and fixture assembly provides equivalent
insertion loss as a Thunderbolt 5 certified cable in the system for
testing.
-
High-speed Tx/Rx electrical signals are acquired using Teledyne
LeCroy’s
DH Series Differential
Probes
connected to the oscilloscope.
-
Low-speed signals are accessed via 2.5 mm square pins that can be
connected to the oscilloscope using either passive or active probes.
-
VBUS load current is measured using a current probe.
-
Data signals are input to the protocol analyzer with a user-provided
USB4 cable.
Teledyne LeCroy provides both the oscilloscope for all
high-speed PHY and low-speed sideband electrical signal capture and the
protocol analyzer for protocol information capture.
-
Teledyne LeCroy
WaveMaster 8000HD
Series
oscilloscope is a single test oscilloscope for all USB-C electrical
signal capture.
-
Teledyne LeCroy
USB protocol analyzers
are the leading protocol analyzers for USB-C, Thunderbolt, and Power
Delivery.
The CrossSync PHY software option for your Teledyne LeCroy oscilloscope
enables precise, intuitive navigation between time-correlated USB protocol
analyzer and oscilloscope traces.
- CrossSync PHY navigation bar makes clear the timing relationship between
linked protocol analyzer and oscilloscope captures
- One or many oscilloscope acquisition segments are represented in the
navigation bar
- Protocol analyzer trace represented in the navigation bar
- Common trigger point ensures precise timing alignment between protocol
trace, oscilloscope acquisitions, and navigation bar view
- Oscilloscope timebase and protocol analyzer acquisition window remain
synchronized while navigating through the combined acquisition, for
total confidence in timing behavior
- Selecting a packet on the protocol trace enables zoom traces on the
oscilloscope to the same time window, enabling sub-packet-level
measurement precision
Explore
More
USB’s host-device architecture and host designs often contain multiple
receptacles and attach to almost every type of peripheral while supplying
power in both directions. Retimers and long channels further complicate the
design and interoperability debug.
- Validate and debug Thunderbolt and USB Type-C active link operation by
observing both high-speed electrical and protocol behaviors
simultaneously without disturbing the link.
- Quickly resolve interoperability issues by capturing the entire protocol
stack, high-speed and low-speed sideband, electrical and protocol.
Measure timing relationships between electrical and protocol domains.
- Analyze link training by observing electrical-level results of
protocol-level commands
- Faster root-cause analysis gets products to market faster with
advertised interoperability performance, leading to higher end-user
customer satisfaction.
Coordinating device, host retimer and host SoC exits from USB4, USB 3.2 or
system low power states is complex, especially for legacy devices designed
before retimers were in common use. There is significant potential for the
three link state machines to become misaligned, especially with USB 3.2
devices expecting to handshake directly with the host.
- Protocol Analyzer is set to trigger on low power entry (e.g., CL1_ACK)
— a complex trigger condition commonly supported by protocol
analyzers
but
not by oscilloscopes, and the protocol analyzer cross-triggers the
oscilloscope.
- Oscilloscope then captures the electrical (physical layer) signals,
including Low Frequency Periodic Signaling (LFPS) timings and the
relative timings of device and host transmitter wake up.
- CrossSync PHY software time-correlates and links the two information
displays.
Download
White Paper: Your USB4 and DisplayPort Designs Will Fail Unless
You Understand Link Training
USB and DisplayPort product and test experts from Kandou and Teledyne LeCroy
collaborated on this technical white paper. It explains in detail why your
designs could fail interoperability and how you can debug the problem. Six
common failures and debug scenarios are described in detail:
- USB4
- Entering and Exiting Low Power States
- Legacy USB 3.2 Link Initialization Interoperability
- Incorrect Flip Programming
- Sideband Use (SBU) Glitch Issues
- DisplayPort
- Retimed Clock Frequency Variation
- Compliance Pattern Issues
Download
White
Paper: Your USB4 and DisplayPort Designs Will Fail Unless
You Understand Link Training
Teledyne LeCroy’s WaveMaster 8000HD oscilloscope can directly connect to
low-cost probes (no adapter required) to support sideband signal
probing. Test coupon fixtures provide ability to simultaneously probe
high-speed and low-speed signals on live links. Triggers and decoders
complete the solution.
An all-in-one oscilloscope and innovative test coupon fixtures provide
ability
to simultaneously probe, trigger, and analyze the high-speed and
low-speed sideband signals on live links – something no other supplier
can provide.
Teledyne LeCroy test coupon fixtures (shown in the diagram above) permit
live link probing of all signals at the USB Type-C connector.
- The TF-USB-C-SB USB4
Sideband Test Coupon Fixture provides
sideband signal access (USB 2.0 D+/D-, CC1/CC2, VBUS,
ILOAD, SBU1/SBU2 for USB4-SB and
DisplayPort AUX, various ground signals).
- The TF-USB-C-HS adds
access to high-speed Tx/Rx signals (Tx1, Tx2,
Rx1, Rx2) using DH Series Differential
Probes.
- A short low loss eMarked Cable is included, which when combined with
the test coupon provides the equivalent
loss as a certified Thunderbolt 5 cable, ensuring interoperability
during debug.
The WaveMaster 8000HD
oscilloscope triggers on a USB4 Preset change or other sideband
message and then captures and decodes the sideband messages and other
high-speed data lane traffic for further analysis.
See the whole link using
USB
CrossSync PHY.
ProtoSync is a software option for WaveMaster 8000HD oscilloscopes. It
exports captured physical layer signals from
the oscilloscope to (freely available) Teledyne LeCroy protocol analysis
software. It allows the same protocol
analysis views as a Teledyne LeCroy protocol analyzer but using the
oscilloscope captured data, synchronized with
the oscilloscope capture. It differs from CrossSync PHY in that protocol
analyzer hardware is not required (and
therefore there is no protocol signal triggering).
- The USB 3.2 link is analyzed while data is transferred from the Host
to the Link Partner.
- An ACK occurs on Ch1 as data is transferred on Ch2.
- Simply click on a decoded packet in the protocol view to zoom in on
the corresponding electrical signal details.
USB 3.2 debugging can be more challenging than USB4 and DisplayPort
because there is no low-speed sideband channel. Instead, link
initialization is coordinated using LFPS transmitted on the high-speed
lanes. Debugging such USB 3.2 initialization requires a time-aligned
simultaneous capture of several hundred milliseconds of retimer power
rails, reset pin and I2C communications, and USB 3.2 LFPS signals.
-
USB 3.2 initialization from an independently powered dock device has
started transmitting LFPS (top yellow traces, full capture on the
left, zoom on the right) before the retimer has been programmed
(bottom magenta traces, full capture on the left, zoom on the
right).
-
Zoomed traces (right) show that the retimer reset pin (driven by the
USB PD controller GPIO) was low when the device started transmitting
LFPS, which is unexpected behavior.
-
A complete view of the timing relationships between these signals is
required to determine the PD firmware adjustments needed to solve
USB 3.2 interoperability issues.
USB-C is a reversible connector. One engineering consequence of this is
that the mapping of PCB traces and retimer
pins to high-speed differential pairs depends on the connector
orientation.
-
The traces carrying TX1 in the normal orientation carry TX2 when the
connector is flipped. Retimers need to know
the mapping in order to transport signals correctly between the host
SoC and the USB-C receptacle.
-
Debugging a live USB link with the Teledyne LeCroy WaveMaster/SDA
8000HD Oscilloscope and the TF-USB-C-HS Test
Coupon Fixture allows an engineer to monitor USB PD controller
programming (I2C signals), CC signals, Sideband
Use (SBU), and high-speed lanes simultaneously.
USB and DisplayPort product and test experts from Kandou and Teledyne
LeCroy collaborated on this technical white
paper. It explains in detail why your designs could fail
interoperability and how you can debug the problem. Six
common failures and debug scenarios are described in detail:
- USB4
- Entering and Exiting Low Power States
- Legacy USB 3.2 Link Initialization Interoperability
- Incorrect Flip Programming
- Sideband Use (SBU) Glitch Issues
- DisplayPort
- Retimed Clock Frequency Variation
- Compliance Pattern Issues
Download
White
Paper: Your USB4 and DisplayPort Designs Will Fail Unless
You Understand Link Training
Best Automated Compliance Test Integration of All
Instruments
Complete test and reporting for all USB-IF required USB4
compliance tests.
- One single unified control and automation test framework for the
oscilloscope, BERT and network analyzer
- Easier to use than multiple test frameworks from multiple vendors
- Completes the validation faster - saves time
Explore More about
QualiPHY 2 Compliance Test Framework.
Increased Test Efficiency
Run Tx and Rx compliance testing separate from the
oscilloscope
- Utilizes QPHY2-PC to perform
testing
offline without connection to
the oscilloscope or BERT
- Increases the use of test equipment hardware for the most important
functions – as data acquisition engines
- Reduces total test time - bring products to market faster
Explore More about
QPHY2-PC.
USB-IF Required USB4 Tx/Rx Test Cable De-Embed, Tx/Rx
Return Loss and Rx Channel Measurements
Teledyne LeCroy’s
QPHY2-USB4-TX-RX
automated compliance test software supports the following required return
loss and S-parameter compliance test measurements:
Fast and Easy Transmitter Testing and Debug
USB 3.2 compliance testing to “Gold Suite” levels
Receiver Testing Using Industry-Standard Anritsu
MP1900A BERT
Fully-automated Rx stressed signal calibration and
receiver BER testing
- Single compliance test framework for all Tx and Rx tests
- Anritsu MP1900A fully integrated into QualiPHY automated compliance
test framework
- Automated short and long-channel calibration using oscilloscope,
BERT and USB-IF compliance fixtures
- USB-IF compliance test report for all tests
Type-C Sideband, Alt Mode and PHY-logic debug
Teledyne LeCroy provides unique capabilities for Power
Delivery, Alt Mode, and USB PHY-logic testing
Read More:
Cross-Layer Analysis
Select USB Standard in SDA Expert
Simply select the USB serial standard from a pre-defined list and gain
instant test expertise for measuring and characterizing USB signals.
Available with USB technology options for SDA Expert.
-
Easily configurable test point setup
-
Comprehensive Eye, Jitter, and other USB-C PHY measurements
-
Simple, powerful equalization analysis
Explore More
Configure USB Test Point
Test Point Configuration lets you perform transmitter testing at any test
point in the link. The dynamic test point diagram changes based on your
selection, in order to reduce setup errors.
-
Test at the ‘PHY Si’ test point by using a measured S-parameter file to
de-embed back to the transmitter pins
-
Select TP2 and connector type to test at the device connector
-
Select TP4_EQ to embed the standard’s cable model and apply equalization
Use the WavePulser 40iX to create S-parameter
files for embedding, de-embedding, and channel emulation for serial data
analysis.
Explore More
Select USB Measurements
USB-C technology specific measurements defined in the USB4, Thunderbolt, USB
3.2, and DisplayPort CTS (compliance test specifications) are accessible at
a touch of a button in SDA Expert software.
-
USB Transmitter Equalization (TxEq, TX-FFE) measurements
-
USB Eye Testing - Eye Height, Eye Width, Eye Mask Testing
-
Amplitude – ACCM (AC Common mode), Pk-Pk Voltage, SNDR
-
Jitter – RJ (Random Jitter), DJ (Deterministic Jitter), TJ (Total
Jitter), UJ (Uncorrelated Jitter), UDJ (Uncorrelated Deterministic
Jitter), OEJ (Odd-Even Jitter)
-
SSC (Spread Spectrum Clock) – SSC Frequency Variation, SSC Rate, SSC
Range
Explore More
Teledyne LeCroy provides the oscilloscopes, automated compliance test
software, active probes, and protocol layer
tools for host, device and hub USB 2.0 electrical compliance and debug
testing, whether implemented standalone or as
part of a USB-C connector.
-
QPHY-USB
automated compliance test software.
-
Live link probing with the
TF-USB-C-SB
Test Coupon Fixture and active differential probes compatible with
coupon fixtures for complete compliance and
live-link signal probing and acquisitions.
-
A full range of protocol decoders, protocol analysis software, and
protocol analyzers.
-
Full range of oscilloscope bandwidths to support basic USB 2.0
compliance through all USB-C testing.
QPHY-USB test software
implements a full set of USB-IF approved electrical tests
for USB 2.0, including High-, Full-, and Low-speed tests.
- Support for host, device, and hub testing.
- Simple and easy-to-use automated testing.
-
Available
TF-USB-B test fixture.
Watch Video: Is the USB You
Designed
Perfect? This is How You Test It.
Teledyne LeCroy test coupon fixtures permit live link probing of all
signals at the USB Type-C connector.
Teledyne LeCroy offers a rich set of triggers and protocol decoders to
debug interoperability failures using oscilloscope.
-
USB 2.0 TDME
– Trigger, Decode Measurements, and Eye Diagram software.
-
HSIC D
– High-speed Inter-Chip decode software for oscilloscopes.
-
USB 2.0 ProtoSync
– Protocol analyzer software for a more detailed view of
protocol traffic using the oscilloscope acquisition data.
-
Access USB 2.0 D+/D- live signal traffic using
TF-USB-C-SB
Sideband Test Coupon Fixtures.
Read More about
Trigger, Decode, Measure/Graph and Eye Diagram Debugging
Options.
Recommended Teledyne LeCroy oscilloscope models for USB 2.0 testing:
-
WaveMaster 8000HD
high-bandwidth oscilloscopes for USB-C and all USB-C testing (USB4,
USB 3.2, USB 2.0, Thunderbolt, and DisplayPort) – a single
test oscilloscope for all low-speed and high-speed signals.
-
WavePro HD
oscilloscopes with up to 8 GHz of bandwidth for USB 2.0 compliance
and USB-C sideband testing.
Recommended Teledyne LeCroy protocol analyzers for USB 2.0 testing:
-
Advisor T3
– portable, affordable USB analyzer for USB 2.0 and USB 3.2.
-
Mercury T2P/T2C
– pocket-sized USB Type-C and Power Delivery analyzer for USB
2.0, Power Delivery 3.2, SBU, and DP AUX.
-
Mercury T2 classic USB analyzer for USB 2.0.
Explore More
about Teledyne LeCroy USB protocol analyzers and exercisers.
USB Power Delivery (PD) signals are an integral part of the USB Type-C
interface. Proper correlation between PD events and other USB-C
low-speed and high-speed signals must be established to ensure
interoperability. Teledyne LeCroy supplies the full range of equipment
for interoperability testing, from electrical test and debug to protocol
compliance.
- Test coupon fixtures for live-link signal probing and acquisitions.
- Oscilloscope-based triggers, decoders, and more for USB PD, USB
Type-C Alt Mode, and DP AUX.
- Protocol analyzers for USB PD and USB Type-C compliance.
USB PD TDMP
(USB Power Delivery Trigger, Decode, Measure/Graph, Physical Layer
Measurements) is the most comprehensive oscilloscope-based USB Power
Delivery test solution. It enables USB Power Delivery power-supply
validation and debug by correlating CC, VBUS, and
ILOAD signals. Time-correlate USB PD with other USB Type-C
connector protocols.
- Access CC1/CC2, VBUS, and ILOAD using the
TF-USB-C-SB debug coupon.
- Trigger on PD preamble, ordered sets, messages, and errors.
- Decode SPR and EPR PD messages, Power Delivery Objects (PDOs), and
more.
- Measure/Graph electrical voltage, current, and timing parameters.
- Physical Layer BMC eye mask testing and measurements.
DP-AUX TDMP
(DisplayPort AUX Trigger, Decode, Measure/Graph, Physical Layer
Measurements) is the most comprehensive oscilloscope-based DisplayPort
AUX Channel test solution. It supports DisplayPort 2.0/1.4 and embedded
DisplayPort (eDP) standards.
- Trigger and decode DisplayPort AUX reads/writes (native or I²C).
- DisplayPort AUX eye diagram PHY compliance testing.
- USB Type-C system-level debug simultaneously with Main Link or USB
Power Delivery.
Teledyne LeCroy provides protocol analyzers, exercisers, and generators
for DisplayPort AUX channel and DisplayPort main links.
DisplayPort Test Solutions for Test Labs and
Developers
VESA defines the DisplayPort PHY compliance test specification (CTS). The
latest DisplayPort 2.1 version supersedes the legacy DisplayPort 1.4b and
significantly increases data rates, creating more design challenges, PHY
compliance test time, and likelihood of interoperability failures. Teledyne
LeCroy DisplayPort 2.1 test solutions provide:
- PHY compliance source testing
- PHY compliance sink testing
- Interoperability validation with combined PHY and protocol debug
Explore More
about DisplayPort PHY Test and Interoperability Testing.
USB-C High-speed Oscilloscope Features
|
| Required 25 GHz Bandwidth |
| Required 80GS/s Sample Rate |
| Resolution |
| Max Record Length |
| High-speed Inputs (50 Ohm) |
| Sideband Inputs (1M Ohm) |
| Sideband Triggers |
| High-speed Data Bus Decoders |
| Protocol Analysis on Oscilloscope Data |
| Sideband Triggers and Decoders |
| Sideband PHY Measurements |
| Sideband MSO Trigger & Decode |
| Built in USB-C technology options |
| PHY Tx (Source) Compliance Software |
PHY Rx (Sink) Compliance Software USB4 and Thunderbolt
USB 3.2
DisplayPort 2.1/1.4 |
| PHY-Logic Layer Test Fixture |
| Cross-layer Analysis |
Front Panel SuperSpeed USB Ports |
|
|
|
|
| 10 bits |
| 2 Gpts |
|
| --- |
| --- |
| --- |
| --- |
| Decode Only |
| --- |
| --- |
| --- |
|
Using JBERT Yes
Yes
Yes |
| Active Link Fixture |
| --- |
| --- |
Tektronix DPO70000SX Series
|
|
|
| 8 bits |
| 500 Mpts |
|
| --- |
| --- |
| --- |
| --- |
| --- |
| --- |
| --- |
| --- |
|
Using MP1900A Yes
No
No |
| --- |
| --- |
| --- |
WaveMaster 8000HD
oscilloscopes
support all generations of USB and DisplayPort Tx/Rx testing at all
required bandwidths:
- 25 GHz for USB4, Thunderbolt, and DisplayPort UHBR.
- 16 GHz for USB 3.2 (Gen2) and DisplayPort HBR3.
- 13 GHz for USB 3.2 (Gen1) and DisplayPort RBR/HBR/HBR2.
- All models support USB 2.0.
The Anritsu SQA-R MP1900A
Signal Quality Analyzer is a high-speed BERT solution in one box. With
time and temperature jitter drift of less than ±2% (2 days, ±5°C), the
MP1900A provides exceptional signal quality for highly repeatable
results. It combines:
- Jitter and noise generation for all Sink and Rx calibration and BER
testing.
- High-quality waveform PPG with integrated 10-tap emphasis.
- LTSSM loopback and error detector with variable CTLE for USB 3.2 Rx
testing.
Watch Video
on Anritsu USB4 v2 Calibration Demonstration Guide.
The WavePulser 40iX Interconnect Analyzer
performs network analysis S-parameter measurements for USB-IF required
return loss and Rx channel measurements.
- Tx/Rx Test Cable De-Embed.
- Tx/Rx Return Loss.
- Rx Channel Measurements.
Explore More
about WavePulser 40iX Interconnect Analyzer.
QualiPHY 2 software Options:
QPHY2-USB4-TX-RX
,
QPHY-USB3.2-TXRX
,
QPHY-USB (2.0)
,
QPHY2-DP2-SOURCE-TX
, and
QPHY2-DP2-SINK-RX
.
fully automate all aspects of USB-C PHY Tx, Rx, and Return Loss
compliance testing. Teledyne LeCroy provides full application support
for all USB integrated electrical compliance test solutions.
- Transmitter (Source) Testing and Receiver (Sink) Compliance Testing.
- Return Loss Compliance Testing.
- Sideband (USB4-SB and DP-AUX) Compliance Testing.
- Report Generation.
Explore More
about QualiPHY automated compliance test software.
USB-C High-speed Oscilloscope Features
|
| Bandwidth |
| Resolution |
| Max Sample Rate |
| Max Record Length |
| Sideband Triggers |
Data Bus Decoder
USB 3.2 (Gen1)
USB 2.0 |
| Sideband MSO Trigger & Decode |
| USB 2.0 Compliance Software |
| Sideband PHY-Logic Capabilities |
| PHY-Logic Test Coupon |
Protocol Analysis on Oscilloscope Data USB 2.0 and USB 3.2
(Gen1) |
|
|
| 2 – 6 GHz |
| 10 bits |
| 16 GS/s |
| 1.6 Gpts |
|
--
|
| --- |
|
| Trigger Decode |
| Active Link Fixture |
| --- |
|
|
| 2 – 6 GHz |
| 12-bit ADC |
| 12-bit ADC |
| 1 Gpt |
| --- |
-- -- |
| --- |
|
| --- |
| --- |
| --- |
| DOCUMENT NAME |
|
| Data Sheet – USB Test Solutions
All-In-One Solution for USB and USB-C® Electrical Test
Compliance and Debug
|
Datasheet
|
| Data Sheet – USB4 Solutions
The complete range of electrical and combined electrical+protocol
test validation, compliance, and debug for USB4.
|
Datasheet
|
| Data Sheet – USB 3.2 PHY Test Solution
Since becoming the first USB-IF "Gold Suite" in 2011, Teledyne
LeCroy continues to be the trusted leader in all the latest USB
Type-C technologies including USB 3.2. Teledyne Lecroy goes
beyond compliance to provide the deepest signal integrity and
cross layer (protocol/electrical) toolbox for system level debug
available.
|
Datasheet
|
| Data Sheet – USB 2.0 Compliance Testing
The USB package provides a complete acquisition and analysis
system for USB 2.0 devices, hosts, and hubs, as specified in the
USB-IF USB 2.0 Electrical Test Specification.
|
Datasheet
|
| TF-USB-C Test Coupon Fixtures
PHY logic layer and sideband negotiation issues account for many
compliance and interoperability failures in USB Type-C connected
devices. These failures can be quickly debugged using unmatched
PHY-logic layer and sideband debug solutions on a wide range of
oscilloscopes
|
Datasheet
|
| USB CrossSync PHY
Interoperability issues can lead to finger-pointing exercises
that cost money and time-to-market. Teledyne LeCroy CrossSync
PHY software merges the functions of your Teledyne LeCroy
protocol analyzer and oscilloscope - giving insight into link
behavior that no other instrument can provide.
|
Datasheet
|
| Data Sheet – USB4 Decode, Measure, Eye (DME)
USB4bus DME (Decode, Measure/Graph, and Eye Diagram) software
provides eye diagram measurements recovering the clock on
decoded
symbols. Evaluate high-speed signal quality during link training
as the transmitter sends SLOS (Symbol Lock Ordered Sets) to the
receiver during link training.
|
Datasheet
|
| Data Sheet – USB 3.2 Decode
The USB 3.2 decode option for Teledyne LeCroy oscilloscopes
provides link layer decode information annotated on the USB 3.2
physical layer waveforms. This provides the ability to view
protocol traffic on the oscilloscope and verify that the link is
alive and transmitting properly.
|
Datasheet
|
| Data Sheet – USB-C (USB 2.0, USB-PD, DP-AUX, USB4-SB)
TDMP
Teledyne LeCroy’s Trigger (T), Decode (D), Measure/Graph (M or G)
and Eye Diagram and Physical Layer (E or P) options are the best
in the industry and nearly universally available across the
entire Teledyne LeCroy oscilloscope product line
|
Datasheet
|
| Data Sheet – ProtoSync
The USB 3.2 decode option for Teledyne LeCroy oscilloscopes
provides link layer decode information annotated on the USB 3.2
physical layer waveforms. This provides the ability to view
protocol traffic on the oscilloscope and verify that the link is
alive and transmitting properly.
|
Datasheet
|
| Your USB4 and DisplayPort Designs Will Fail Unless You
Understand Link Training
Complex USB4 and DisplayPort 2.1 protocol, electrical and signal
integrity issues can manifest themselves in difficult-to-solve
link problems, requiring new approaches to testing and debug to
ensure high quality and reliable products. Download the White
Paper to learn more.
|
Download
|
| USB 3.2 Debug using the TF-USB-C-HS Fixture
This guide covers how to debug USB 3.2 systems using the
TF-USB-C-SH test coupon fixture, DH-PX series differential
probes, R4060 Rail Probe, CP031A current probe, and USB32busD
decode and Protosync software on the WaveMaster/SDA800 HD
oscilloscope.
|
Download
|
| USB 2.0 Compliance and Debug Reference Guide
This guide provides detailed setups and expected results for USB
2.0 device compliance testing using QPHY-USB (USB 2.0
Compliance) test software as well as debugging USB 2.0 protocol
failures using USB2bus TDMP software.
|
Download
|
| USB 2.0 Debug using the TF-USB-C-SB Fixture
This guide covers how to debug USB 2.0 systems using the
TF-USB-C-SB test coupon fixture, ZD1500 differential probe,
CP031A current probe, and USB2busD USB 2.0 bus decode software
on Teledyne LeCroy HD oscilloscopes of all bandwidths.
|
Download
|
| Power Delivery Debug using the TF-USB-C-SB Fixture
This guide covers how to debug USB Power Delivery using the
TF-USB-C-SB test coupon fixture, passive probes, CP031A current
probe, and USB-PD TDMP Power Delivery Trigger, Decode,
measure/graph, and physical layer test software on Teledyne
LeCroy HD oscilloscopes of all bandwidths. USB Power Delivery
Compliance debug is performed by adding M310e Power Delivery
Analyzer.
|
Download
|
Serial data electrical/PHY validation can be complex,
time-consuming and costly. This webinar will present
best practices and the latest automated test methods
for high-speed serial SerDes Tx, Rx, and return loss
compliance and validation.
USB 2.0 is a common serial data and power delivery
standard which is integrated into many new
electrical designs. Join Teledyne LeCroy to learn
new methods and measurement techniques for rapid
debugging of USB 2.0 electrical issues.
USB Type-C® Technologies PHY Testing Webinar Series
Join Teledyne LeCroy for our webinar series on USB
Type-C technologies with a focus on the physical layer, from an
introduction to the various technologies in the Type-C ecosystem
to USB 3.2, USB4™, Thunderbolt™, DisplayPort™, USB4 Type-C
sideband (USB Power Delivery, DisplayPort AUX, USB4 SB) testing.
Register
for all
Part 1 - Part 1 Introduction to USB
Type-C® Technologies Physical Layer Testing
The USB Type-C connector is quickly becoming the PC
industry’s standard for converged high-speed data,
display (video) and power delivery. In this session
we will provide an overview of all the electrical
signals sent over the USB Type-C connector and how
to test them.
Part 2 – USB 3.2 Physical Layer
Compliance Test Overview
In this session we focus on the USB 3.2 specification
given its ubiquitous use for USB peripherals. We
will cover new test requirements for the USB 3.2 CTS
and the tools for testing it.
Part 3 – USB4® Version 1.0
and Thunderbolt Physical Layer Compliance Testing
In this session we will provide an update of the
latest tools available for USB4 electrical
validation and compliance testing and requirements
to adhere to the USB-IF’s test program.
Part 4 – How to Debug USB4™ and USB 3.2
PHY-logic and Sideband Links
In this session we will focus on compliance and
interoperability (C&I) of USB Type-C connected
hosts, hubs, adapters, and peripherals, with
practical approaches to debugging electrical system
issues that may occur when connecting USB-C devices
together and meeting all USB-IF and Thunderbolt
Specifications
Part 5 - How to Perform DisplayPort™ 2
Physical Layer Compliance Testing and Debug
In this session we review the latest PHY test
requirements DisplayPort 2. Source and Sink test
updates and new VESA compliance program
requirements.
Part 6 – USB4® Version 2.0
Tx/Rx Physical Layer Compliance Testing
Join Teledyne LeCroy as we provide an update on
USB4® Version 2.0 electrical validation
and compliance testing, the latest tools available,
and challenges you might encounter in meeting the
timelines of the USB-IF test program.
QPHY2-USB4-TX-RX Overview
USB-C Test Coupon Fixtures
USB Type-C Sideband Testing
USB4 Transmitter Compliance
USB4 S-parameter Measurements
USB 3.2 PHY and PHY-Logic Testing
USB 3.2 Transmitter Compliance
USB 3.2 Receiver Compliance
USB Power Delivery Measurements
DisplayPort Alt Mode Debug
USB Type-C®, and USB-C®,
USB4® are trademarks of the USB Implementers Forum (USB-IF) and are intended for
use with products based on and compliant with USB Type-C cable and connector specification.
DisplayPort™ is a trademark of Video Electronics Standards Association (VESA). Thunderbolt™ is a
trademark of Intel Corporation.