Products
Oscilloscopes

MDA800A Motor Drive Analyzers

Motor Drive Analyzers provide complete three-phase electrical and mechanical power analysis with static power results in a convenient, configurable Numeric table and dynamic power displayed as per-cycle Waveforms. Motor speed, position, and torque integration are the most complete available. Zoom+Gate mode provides ability to understand and isolate dynamic behaviors. Long memory, 8 analog input channels (MSO optional) with high resolution (12-bits), sample rate, bandwidth and memory (up to 250 Mpt/ch) provides unique capability to perform complete system debug on the inverter subsection, embedded control system, and motor mechanical performance.

Explore MDA800A Motor Drive Analyzers Explore MDA800A Motor Drive Analyzers
MDA803A   (350 MHz Bandwidth, 8 Input Channels, 10 GS/s)
Quick Specs
Bandwidth350 MHz
Sample Rate10 GS/s on 4 Ch with ESR
Maximum Acquisition Memory250 Mpts (8 Ch operation)
Input Channels8
Vertical Resolution12-bits
MDA805A   (500 MHz Bandwidth, 8 Input Channels, 10 GS/s)
Quick Specs
Bandwidth500 MHz
Sample Rate10 GS/s on 4 Ch with ESR
Maximum Acquisition Memory250 Mpts on all 8 channels
Input Channels8
Vertical Resolution12-bits
MDA810A   (1 GHz Bandwidth, 8 Input Channels, 10 GS/s)
Quick Specs
Bandwidth1 GHz
Sample Rate10 GS/s on 4 Ch with ESR
Maximum Acquisition Memory250 Mpts on all 8 channels
Input Channels8
Vertical Resolution12-bits
Check up to three models.
Key Features
  • Oscilloscope + Power Analyzer in one instrument
    • Static power analysis (like a power analyzer)
    • Dynamic power analysis (unique to the MDA)
    • Complete system debug capabilities (unique to the MDA)
  • Zoom+Gate
  • Comprehensive speed and torque interface
  • Harmonics Analysis option (MDA800-HARMONICS)
  • Intuitive, graphical user interface

 

Oscilloscope + Power Analyzer

The Motor Drive Analyzer is built on the 8ch/12-bit HDO8000A platform. It contains all of the advanced oscilloscope capability you need for embedded control debug plus three-phase power and mechanical analysis with accuracy to within 1% of a dedicated power analyzer instrument.

Static Power Analysis

Like a power analyzer, the MDA can acquire short records under steady-state operating conditions and provide fast updates of mean value power quantities in the Numerics table. Power quantities can be calculated on a line frequency AC period, a variable frequency PWM output period, or over a very short time period, such as the device switching period.

Dynamic Power Analysis

Long memory (up to 250 Mpts/ch) permits capture and analysis of long periods of time (e.g. 25 seconds at 10 MS/s). Touch a Numerics table cell and create a per-cycle "synthesized" Waveforms of the parameter over time.Zoom+Gate adds further value for dynamic analysis. Correlate complex drive behaviors to other control or power system waveforms, and debug drive system problems faster.

Complete System Debug

Power Analyzer instruments perform only one function, and typical 4 channel oscilloscopes have limited capabilities for three-phase power system analysis. The Motor Drive Analyzer has 8 analog input channels (+16 optional digital channels) and three-phase power analyzer capability to debug the complete motor drive system.

Zoom+Gate

Zoom your acquisitions and Gate both the Numerics measurement table and the per-cycle Waveforms to the zoomed area. Gain deeper and faster understanding of complex drive and control system behaviors.

Harmonics Analysis Option

Apply a discrete fourier transform (DFT) harmonic filter to acquired voltage and current waveforms. Harmonically filter Numerics table results more accurately than brute force hardware filters. Display per-order Harmonics in a table along with up to 9 spectral waveforms. View per-cycle THD values over time.

Comprehensive Speed and Torque Interface

Interface digital or analog speed sensors with Angle Tracking Observer filtering. Extract speed information from CAN serial data. Use digital (MSO) inputs to conserve valuable analog channels. Interface a variety of torque sensors, extract torque from CAN serial data, or infer torque from motor current and a known torque constant. At your bench, calculate motor Speed and Torque without additional expensive equipment.

Intuitive, graphical user interface

An easy-to-understand user interface guides the operator through setup and analysis. Setup capability is provided for any combination of single-phase or three-phase drive input/output. Quick buttons provide fast access to advanced capabilities.

Main Specifications

Bandwidth 350 MHz - 1 GHz
Starting from $30,900
Standard Memory 50 Mpts - 250 Mpts
Max Sampling Rate 10 GS/s
Input Channels 8
Resolution 12-bit
 

SAM40

SAM40-8
Sensor Acquisition Module, 8 input channels, 40 kHz bandwidth. Must be used with 12-bit HDO.
SAM40-16
Sensor Acquisition Module, 16 input channels, 40 kHz bandwidth. Must be used with 12-bit HDO.
SAM40-24
Sensor Acquisition Module, 24 input channels, 40 kHz bandwidth. Must be used with 12-bit HDO.

Mixed Signal Solutions

HDO8k-MSO
HDO8000/MDA800 Series Model Mixed-Signal Option

Memory Options

HDO8KA-L
100 Mpt/Ch Memory Option for HDO8000A
HDO8KA-XL
250 Mpt/Ch Memory Option for HDO8000A

Computer Upgrade

HDO8k-256GB-SSD-02
Addl 256GB Removable Solid-state Drive for HDO8000A. Includes Windows 7 OS, Teledyne LeCroy oscilloscope software and critical scope operational file duplicates
HDO8kA-16-UPG-32GBRAM
16 GB to 32 GB CPU RAM Upgrade Option

Remote Control/Network Options

USB2-GPIB
External USB 2.0 to GPIB IEEE 488.2 adapter

Power Analysis Software

MDA800-Harmonics
MDA Harmonics Calculation Option
HDO8k-PWR
Power Analysis Option for HDO8000/MDA800

Serial Trigger and Decode

HDO8k-1553 TD
MIL-STD-1553 Trigger and Decode Option for HDO8000/MDA800
HDO8k-SPMIbus D
SPMI Decode for HDO8000 Series
HDO8K-MDIObus D
MDIO Decode for HDO8000 Series
HDO8k-ARINC429bus DSYMBOLIC
ARINC 429 Bus Symbolic Decode option for HDO8000
HDO8k-AudioBus TD
AudioBus trigger and decode option for HDO8000/MDA800
HDO8k-AudioBus TDG
AudioBus trigger, decode, and graph option for HDO8000/MDA800
HDO8k-CAN FDbus TD
CAN and CAN FD Trigger and Decode Option for HDO8000/MDA800
HDO8k-CANbus TD
CAN Trigger and Decode Option for HDO8000/MDA800
HDO8k-DigRF3Gbus D
DigRF 3G Bus Decode option for HDO8000/MDA800
HDO8k-DigRFv4bus D
DigRF V4 Bus Decode option for HDO8000/MDA800
HDO8k-DPHYbus D
D-PHY Bus Decode option for HDO8000/MDA800
HDO8k-ENETbus D
ENET Bus Decode Option for HDO8000/MDA800
HDO8k-FlexRaybus TD
FlexRay Trigger and Decode Option for HDO8000/MDA800
HDO8k-I2Cbus TD
I2C Trigger and Decode Option for HDO8000/MDA800
HDO8k-LINbus TD
LIN Trigger and Decode Option for HDO8000/MDA800
HDO8k-Manchesterbus D
Manchester Bus Decode Option for HDO8000/MDA800
HDO8k-NRZbus D
NRZ Bus Decode Option for HDO8000/MDA800
HDO8k-ProtoBus MAG
Serial Debug Toolkit - Measure Analyze Graph for HDO8000/MDA800
HDO8k-SENTbus D
SENT Bus Decode Option for HDO8000/MDA800
HDO8K-SpaceWirebus D
SpaceWire Decode Option for HDO8K series
HDO8k-SPIbus TD
SPI Trigger and Decode Option for HDO8000/MDA800
HDO8k-UART-RS232bus TD
UART-RS232 Trigger and Decode Option for HDO8000/MDA800
HDO8k-USB2-HSICbus D
USB 2.0 HSIC Decode Option for HDO8000/MDA800
HDO8k-USB2bus TD
USB 2.0 Trigger and Decode Option for HDO8000/MDA800

Jitter Analysis Software

HDO8k-JITKIT
Clock, clock-data Jitter Analysis and views of time, statistical, spectral, and jitter overlay

Digital Filtering Software

HDO8k-DFP2
Digital Filter Software Package for HDO8000/MDA800

Other Software Options

HDO8k-EMC
EMC Pulse Parameter Software Package for HDO8000/MDA800
HDO8k-XDEV
Advanced Customization Option for HDO8000/MDA800

Serial Data Analysis

HDO8k-SDM
Serial Data Mask Software Package for HDO8000/MDA800

Miscellaneous

OC1024-A
Instrument Cart with additional shelf and drawer
OC1021-A
Instrument Cart
HDO8k-SOFTCASE
HDO8000 Soft Carrying Case
HDO8k-RACKMOUNT
HDO8000 Rack Mount Accessory
HDO8k-FP-CHNES-SI
HDO8000/MDA800 Simplified Chinese Front Panel Overlay
HDO8k-FP-CHNES-TR
HDO8000/MDA800 Traditional Chinese Front Panel Overlay
HDO8k-FP-FRENCH
HDO8000/MDA800 French Front Panel Overlay
HDO8k-FP-GERMAN
HDO8000/MDA800 German Front Panel Overlay
HDO8k-FP-ITALIAN
HDO8000/MDA800 Italian Front Panel Overlay
HDO8k-FP-JAPANESE
HDO8000/MDA800 Japanese Front Panel Overlay
HDO8k-FP-KOREAN
HDO8000/MDA800 Korean Front Panel Overlay
HDO8k-FP-RUSSIAN
HDO8000/MDA800 Russian Front Panel Overlay
HDO8k-FP-SPANISH
HDO8000/MDA800 Spanish Front Panel Overlay

Mixed Signal Accessories

PK400-0
Extra Large Gripper Probe Set . Includes 22 probes

High Voltage Fiber Optically-isolated Probes

HVFO103
High Voltage Fiber Optic Probe, 60 MHz Bandwidth. Includes soft-carrying case. Requires attenuating tip (ordered separately). Includes Qty. 1 1m Fiber Optic Cable.
HVFO100-1X-TIP
HVFO103 +/-1V (1x Attenuation) Tip Accessory
HVFO100-5X-TIP
HVFO103 +/-5V (5x Attenuation) Tip Accessory
HVFO100-20X-TIP
HVFO103 +/-20V (20x Attenuation) Tip Accessory
HVFO103-XMITTER
HVFO103 Spare Amplifier/Modulating Transmitter
HVFO-1M-FIBER
HVFO 1m Fiber Optic Cable Accessory
HVFO-2M-FIBER
HVFO 2m Fiber Optic Cable Accessory
HVFO-6M-FIBER
HVFO 6m Fiber Optic Cable Accessory

Probe Adapters

TPA10
TekProbe to ProBus Probe Adapter
TPA10-QUADPAK
Set of 4 TPA10 TekProbe to ProBus Probe Adapters. Includes soft carrying case.

Active Voltage Rail Probe

RP4030
Power/Voltage Rail Probe. 4 GHz bandwidth, 1.2x attenuation, +/-30V offset, +/-800mV Includes a complete set of solder-in leads, coaxial cables, and PCB mounts.
RP4000-BROWSER
RP4030 350 MHz Browser Tip accessory. Includes 0 Ohm (1x), 450 Ohm (10x) and 950 Ohm (20x) tips.
RP4000-MCX-LEAD-SI
Qty. 3 MCX 4 GHz solder-in lead accessories (additional to those supplied with RP4030), 18cm long
RP4000-MCX-PCBMOUNT
Qty. 10 MCX 6mm x 6mm PCB mounts (additional to those supplied with RP4030)
RP4000-MCX-CABLE-UFL
Qty. 3 3 GHz MCX to U.FL ultra-miniature coax cable, 8cm long (add'l to those supplied with RP4030)
RP4000-UFL-PCBMOUNT
Qty. 10 U.FL 3mm x 3mm PCB mounts (additional to those supplied with RP4030)

Active Voltage Probes

ZS1000
1 GHz, 0.9 pF, 1 MOhm Active Voltage Probe
ZS1500
1.5 GHz, 0.9 pF, 1 MOhm Active Voltage Probe
ZS1000-QUADPAK
Set of 4 ZS1000, 1 GHz High Impedance Active Probes
ZS1500-QUADPAK
Set of 4 ZS1500, 1.5 GHz High Impedance Active Probes

Current Probes

CP030
30A, 50 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP030-3M
30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 3 meter cable
CP030A
30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP031
30A, 100 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP031A
30A, 100 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP150
150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 2 meter cable
CP150-6M
150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 meter cable
CP500
500 A, 2 MHz Current Probe - AC/DC, 500 A rms, 700 A Peak Pulse, 6 meter cable
CA10
Programmable Current Sensor to ProBus Adapter for use with third party current sensors
CA10
Programmable Current Sensor to ProBus Adapter for use with third party current sensors
CA10-QUADPAK
Set of 4 CA10 Programmable Current Sensor to ProBus Adapters for third-party current sensors
DCS015
Deskew Calibration Source for CP031,CP031A, CP030, CP030A and AP015 Limited Availability
DCS025
Deskew Calibration Source for CP030, CP030A, CP031, CP031A, AP015, CP150, CP500

Differential Amplifiers

DA1855A
1 Ch, 100 MHz Differential Amplifier with Precision Voltage Source
DXC100A
÷100 or ÷10 Selectable, 250 MHz Passive Differential Probe Pair
DXC200
÷1, 50 MHz, Passive Differential Probe Pair
DXC-5100
100:1 250 MHz 40 Mohm 2.75pf Differential Probe Pair;
DA101
10:1 1 MOhm Passive Attenuator
DA1855A-PR2
2 Ch, 100 MHz, Differential Amplifier with Precision Voltage Source
DA1855A-PR2-RM
2 Ch, DA1855A with Rackmount (must be ordered at time of purchase, no retrofit)
DA1855A-RM
DA1855A with rackmount;

Differential Probes (<= 1.5 GHz)

AP033
500 MHz Differential Probe
ZD1000
1 GHz, 1.0 pF Active Differential Probe, ±8 V
ZD1500
1.5 GHz, 1.0 pF Active Differential Probe, ±8 V
ZD200
200 MHz, 3.5 pF, 1 MOhm Active Differential Probe, ±20 V
ZD500
500 MHz, 1.0 pF Active Differential Probe, ±8 V

High Voltage Differential Probes

HVD3102
1kV, 25 MHz High Voltage Differential Probe
HVD3102-NOACC
1kV, 25 MHz High Voltage Differential Probe without tip Accessories
HVD3106
1kV, 120 MHz High Voltage Differential Probe
HVD3106-NOACC
1kV, 120 MHz High Voltage Differential Probe without tip Accessories
HVD3106-6M
1kV, 80 MHz High Voltage Differential Probe with 6m cable
HVD3206
2kV, 120 MHz High Voltage Differential Probe
HVD3206-6M
2kV, 80 MHz High Voltage Differential Probe with 6m cable
HVD3605
6kV, 100 MHz High Voltage Differential Probe
AP031
700 V, 25 MHz High-Voltage Differential Probe (÷10, ÷100)
ADP300
1kV, 20 MHz High-Voltage Differential Probe
ADP305
1kV, 100 MHz High-Voltage Differential Probe

High Voltage Probes

HVP120
400 MHz, 1kV Vrms High-Voltage Passive Probe
PPE4KV
100:1 400 MHz 50 MOhms High-Voltage Probe
PPE5KV
100:1 400 MHz 50 MOhms High-Voltage Probe
PPE6KV
1000:1 400 MHz 50 MOhms High-Voltage Probe

Passive Probes

PP018-1
500 MHz Passive Probe for HDO, 10:1, 10 MOhm
PP023-1
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP026-1
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm

Probe Parts and Kits

HVFO100-40X-TIP
HVFO103 +/-40V (40x Attenuation) Tip Accessory
PACC-ZD001
Y lead Adapter for ZD differential probes - Qty 1
PACC-ZD002
Solder-in lead for ZD differential probe - QTY 2
PACC-ZD003
Long spring ground for ZD differential probe - QTY 2
PACC-ZD004
Tip saver for ZD differential probe - QTY 2
PACC-ZD005
Swivel tip adapter for ZD differential probe - QTY 1
PACC-ZD006
Small IC adapter for ZD differential probe - QTY 2
PACC-ZD007
Replacement Accessory kit for ZD200
PACC-ZD008
Y-Lead Adapter
PK111
Replacement Accessory kit for ZD500, ZD1000, and ZD1500
PKIT4-5MM-101
Standard Accessory Replacement Kit for PP017/PP018

Setup Capability

Measurement LocationsAC Input, DC Bus (Link), Drive Output, Mechanical Output
Wiring ConfigurationsAC Input: 1-phase / 2-wire (1V1A); 1-phase / 3-wire (2V/2A); 3-phase / 3-wire (2V2A); 3-phase / 3-wire (3V3A); 3-phase / 4-wire (3V3A); None
DC Bus: 1-phase / 2-wire (1V1A); None
Drive Output: 1-phase / Half-Bridge (1V1A); 1-phase / Full-Bridge (1V1A); 3-phase / 3-wire (2V2A); 3-phase / 3-wire (3V3A); 3-phase / 4-wire (3V3A); None
Harmonic FilterSelect either Full Spectrum or Fundamental only. With MDA800-HARMONICS option, also select Fundamental + N Harmonics or Range (maximum 50th harmonic in both cases).
Sync (per-cycle) Measurement SignalIndependently settable for AC Input, DC Bus, Drive Output and Mechanical Output.
Low pass filter (LPF) cutoff settable from 20 Hz to 1 MHz. Hysteresis settable from 0-100% full amplitude.
Source can be any input analog channel, memory trace, or math function.
Voltage Measurement MethodLine-Line or Line-Neutral (with L-L to L-N conversion supported)
Calculation Waveform SourcesAny input channel or stored memory trace
 

Numerics Measurement Table Selections (Per-cycle Calculated, Mean Value Displayed)

VoltageRMS voltage, AC Voltage, DC Voltage, Peak Positive Voltage, Peak Negative Voltage, Peak-Peak Voltage, Voltage Crest Factor, Voltage Total Harmonic Distortion (THD) (with the MDA800-HARMONICS option)
CurrentRMS Current, AC Current, DC Current, Peak Positive Current, Peak Negative Current, Peak-Peak Current, Current Crest Factor, Current Total Harmonic Distortion (THD) (with the MDA800-HARMONICS option)
Power, Efficiency, and OtherReal, Apparent, and Reactive Power, Peak Positive Real Power, Peak Negative Real Power, Power Total Harmonic Distortion (THD) (with the MDA800-HARMONICS option), Power Factor, Phase Angle, Incremental Efficiency, Total Efficiency, Frequency
Motor Mechanical + OtherTorque, Speed1, Speed2, Angle1, Angle 2 (as defined by sensor, or adjusted with Offset Angle setting), Mechanical Power, AC induction motor Slip
Source SelectionsVoltage: Va, Vb, Vc, Va-b, Vb-c, Vc-a, Vr, Vs, Vt, Vr-s, Vs-t, Vt-r, Ia, Ib, Ic, Ir, Is, It, Vbus, Ibus, Mechanical.
Up to 10 rows (sources) and 12 columns (measurements) may be displayed in the table at any time. Source selections dependent on Wiring Configuration selections and Line-Line to Line-Neutral selections.
 

Motor Mechanical Interface

Speed + DirectionAnalog Tachometer (0-xVdc = speed). Source is analog input.
Digital Tachometer (x pulse/revolution = speed). Source may be digital or analog input.
Applied Voltage. Source is one analog input.
Controlled Area Network (CAN) Serial Data. Source is CAN message with embedded digital data. CANbus TDM or TDME option must be ordered separately.
Hall Sensors (three digital inputs). Source may be digital or analog input. Angle Tracking Observer filter may be applied to this selection.
Speed + Direction + PositionResolver. Source is three analog inputs.
SinCos. Source is two analog inputs.
KMZ60. Source is two analog inputs.
Quadrature Encoder Interface (QEI) (A, B, and optional Z input). Source may be digital or analog input.
Angle Tracking Observer filter may be applied to all selections.
TorqueAnalog 0-Vdc = Torque. Source is one analog input.
Analog mV/V = Torque. Source is one analog input.
Analog Frequency Modulated = Torque. Source is one analog input.
Motor Constant K * Current = Torque. Source is MDA calculated per-cycle current value.
Controlled Area Network (CAN) Serial Data = Torque. Source is CAN message with embedded digital data. CANbus TDM or TDME option must be ordered separately.
 

Per-cycle "Synthesized" Waveforms and Statistics

WaveformsA time-correlated waveform of any per-cycle Numerics Table measurement parameter may be created and displayed anywhere on the grid. Up to 12 detailed per-cycle Waveforms may be displayed at one time, with up to 40 waveforms total (channels, memories, zooms, math, and per-cycle Waveforms) displayed at any one time.
StatisticsDetailed statistics on up to 12 per-cycle Numerics Table measurement parameters may be displayed at one time.
 

Harmonics Calculation Option (part number MDA800-HARMONICS)

Fundamental Frequency DetectionFixed Frequency Detection mode (for Line AC inputs only) or Varying Frequency Detection Mode (for Line AC inputs or Inverter PWM outputs).
Number of Harmonics CalculatedUp to 100 (Fixed Frequency) or up to 50 (Varying Frequency)
Harmonics Table and Spectral Waveform DisplayDisplay values by Harmonic Order for up to 9 quantities (Voltage, Current and Power) for any or all of three phases (limited to Voltage and Current in Fixed Frequency mode).
Units/Limits SelectionSelect from either Amps/Volts/Watts, %, or dB.
For Fixed Frequency, selection Limits file or create and assign custom limits file.
 

Zoom+Gate Mode

OperationPress "Zoom+Gate" button to create zooms of all voltage, current and mechanical signals (analog or digital) and simultaneously gate the Numerics and Statistics tables to the zoomed area. Displayed per-cycle "synthesized" Waveforms are simultaneously time-correlated to the zoomed area. Scroll through the full acquisition using Zoom position and ratio (size) controls and view instantaneous updates of table values.
 

Typical Accuracy

Voltage, Current and PowerTypically within 1%, depending on voltage and current measurement device.
Recommended voltage probe (line-line voltage sensing) = Teledyne LeCroy HVD Series High Voltage Differential Probe (1kV, 2kV and 6kV isolated models available).
Recommended voltage probe (line-neutral or line-reference voltage sensing) = Teledyne LeCroy HVD Series HV Differential Probe for voltages >50Vrms, Teledyne LeCroy passive probe (Qty. 4 included) for voltages <=50Vrms
Recommended current probes = Teledyne LeCroy CP Series Current Probes
Other voltage and current measurement devices may be interfaced to the oscilloscope and analysis software using built-in rescaling and unit selection capabilities. The CA10 current adapter provides programmability for rescaling and unit selection.
 

Available Options & Accessories

Acquisition Memory100 Mpt/ch (HDO8k-L) and 250 Mpt/ch (HDO8k-XL)
Mixed Signal OptionHDO8k-MSO: 16 digital logic channel acquisition at up to 250 MHz digital clock rate, flexible analog and digital cross-pattern trigger and use of digital logic lines for mechanical speed sensing and serial data clock, data, and chip select probing, including (optional) serial data triggers and decoding
Serial Triggers and DecodersA wide variety are available including I2C, SPI, UART-RS232, CAN, LIN, FlexRay, ARINC429, Audio (I2S), DPHY, DigRF3G, DigRFv4, ENET, Manchester, MIL1553, SENT, USB2, and USB2-HSIC. Symbolic triggering and decoding is available for CAN. ProtoBus MAG Serial Debug Tookit provides automatic serial message timing measurements and serial (digital) data extraction and conversion (D-A capability).
Probes and AccessoriesA comprehensive list of voltage and current probes is supported on the Motor Drive Analyzer. Additionally, rackmounts, carts, soft carrying cases and local language front panel overlays are also available.
Software OptionsInclude Power (Semiconductor Device) Analysis, Digital Filtering, Jitter, EMC/EMI Measurements, and Developer's Toolkit.
 
Consult HDO8000A datasheet for complete list of available options, accessories, and probes