Vertical - Analog Channels |
Analog Bandwidth (Max) | 13 GHz |
Analog Bandwidth @ 50 Ω (-3 dB) (ProLink Input) | 13 GHz |
Analog Bandwidth @ 50 Ω (-3 dB) (ProBus Input) | 2 GHz |
Analog Bandwidth @ 1 MΩ (-3 dB) (ProBus Input) | 500 MHz |
Rise Time (10-90%, 50 Ω) | 34 ps (Flatness mode) |
Rise Time (20-80%, 50 Ω) | 24 ps (Flatness mode) |
Input Channels | 4 (Any combination of 13 GHz ProLink inputs or 2 GHz ProBus inputs) |
Vertical Resolution | 12 bits; up to 15 bits with enhanced resolution (ERES) |
Effective Number of Bits (ENOB) | 5.60 bits |
Vertical Noise Floor (5 mV/div) | 549 µVrms |
Vertical Noise Floor (10 mV/div) | 549 µVrms |
Vertical Noise Floor (20 mV/div) | 672 µVrms |
Vertical Noise Floor (50 mV/div) | 1.28 mVrms |
Vertical Noise Floor (100 mV/div) | 2.63 mVrms |
Vertical Noise Floor (200 mV/div) | 6.50 mVrms |
Vertical Noise Floor (500 mV/div) | 13.05 mVrms |
Vertical Noise Floor (1 V/div) | 25.50 mVrms |
Sensitivity | 50 Ω (ProLink): 5 mV-500 mV/div, fully variable
50 Ω (ProBus): 2 mV - 1 V/div, fully variable 1 MΩ (ProBus): 2 mV-10 V/div, fully variable |
DC Vertical Gain Accuracy (Gain Component of DC Accuracy) | ±1% F.S. (typical), offset at 0V; ±1.5% F.S. (test limit), offset at 0V |
Channel-Channel Isolation | ProBus inputs: DC-200 MHz: 70 dB (>3000:1), 200-500 MHz: 60 dB (>1000:1), 500 MHz - 1 GHz: 50 dB (>300:1), 1 GHz - 2 GHz: 40 dB (>100:1)
ProLink inputs: DC to 13 GHz: 60 dB (>1000:1)
(For any two input channels, same V/div settings, typical) |
Offset Range | ProBus inputs: 50 Ω ±1.6 V @ 1 mV - 4.95 mV/div ±4 V @ 5 mV - 9.9 mV/div ±8 V @ 10 mV - 19.8 mV/div ±10 V @ 20 mV - 1 V/div
1 MΩ ±1.6 V @ 1 mV - 4.95 mV/div ±4 V @ 5 mV - 9.9 mV/div ±8 V @ 10 mV - 19.8 mV/div ±16 V @ 20 mV - 100 mV/div ±80 V @ 102 mV - 198 mV/div ±160 V @ 200 mV - 1 V/div ±400 V @ 1.02 V - 10 V/div
ProLink inputs: 50 Ω: ±500 mV @ 5-100 mV/div ±4 V @ 102 mV/div -500mV/div
|
DC Vertical Offset Accuracy | ±(1% of offset setting + 1% F.S. + 1 mV) (test limit) |
Maximum Input Voltage | ProBus inputs/Aux In 50 Ω: ≤ 5 Vrms ProBus inputs/Aux In 1 MΩ // 20pF ≤ 400 Vpeak ProLink inputs 50 Ω ±2V Vmax |
Input Coupling | ProLink Inputs - 50 Ω: DC, GND ProBus Inputs - 1 MΩ: AC, DC, GND; 50 Ω: DC, GND |
Input Impedance | ProBus inputs: 50 Ω+/-2% or 1 MΩ||20pF, 10 MΩ || 10 pF with supplied passive probe
ProLink inputs: 50 Ω+/-2% |
Bandwidth Limiters | ProBus inputs: 1 MΩ: 200 MHz, 20 MHz 50 Ω: Fully variable from 1 GHz to 2 GHz in increments of 100 MHz, 200 MHz, 20 MHz
ProLink inputs: Fully variable from 1 GHz to instrument bandwidth in increments of 100 MHz |
Rescaling | Length: meters, inches, feet, yards, miles; Mass: grams, slugs; Temperature: celsius, fahrenheit, kelvin; Angle: radian, arcdegr, arcmin, arcsec, cycles, revolutions, turns; Velocity: m/s, in/s, ft/s, yd/s, miles/s; Acceleration: m/s2, in/s2, ft/s2, g0; Volume: liters, cubic meters, cubic inches, cubic feet, cubic yards; Force (Weight): newton, grain, ounce, pound; Pressure: pascal, bar, atmosphere (technical), atmosphere (standard), torr, psi; Electrical: volts, amps, watts, volt-amperes, volt-amperes reactive, farad, coulomb, ohm, siemen, volt/meter, coulomb/m2, farad/meter, siemen/meter, power factor; Magnetic: weber, tesla, henry, amp/meter, henry/meter; Energy: joule, Btu, calorie; Rotating Machine: radian/second, frequency, revolution/second, revolution/minute, N m, lb-ft, lb-in, oz-in, watt, horsepower; Other: %. |
|
Horizontal - Analog Channels |
Timebases | Internal timebase common to 4 input channels |
Time/Division Range | 20 ps/div-5000 s/div (maximum capture time is based on minimum sample rate of 1kS/s and installed memory) |
Clock Accuracy | <0.1 ppm + (aging of 0.05 ppm/yr from last calibration) |
Sample Clock Jitter | up to 1µs Acquired Time Range: 15fsrms (Internal Timebase Reference)
up to 10µs Acquired Time Range: 28fsrms (Internal Timebase Reference)
up to 100µs Acquired Time Range: 32fsrms (Internal Timebase Reference)
up to 1ms Acquired Time Range: 33fsrms (Internal Timebase Reference) |
Delta Time Measurement Accuracy | \sqrt{2}*\sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2) (RMS)+(clock accuracy*reading)(seconds) |
Jitter Measurement Floor | \sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2\; seconds\; rms\; (TIE)} |
Jitter Between Channels | ≤ 275 fsrms (TIE, typical, measured at maximum bandwidth) |
Skew stability Between Channels | 10 fsrms (typical) |
Channel-Channel Deskew Range | 25 ns |
External Timebase Reference (Input) | 10 MHz; 50 Ω impedance, applied at the rear input |
External Timebase Reference (Output) | 10 MHz; 50 Ω impedance, output at the rear |
|
Acquisition - Analog Channels |
Sample Rate (Single-shot) | 80 GS/s on 4 Ch with Enhanced Sample Rate |
Memory Length (4 Ch / 2 Ch / 1Ch) (Number of Segments) | 200 M / 200 M / 200 M (65,535) |
Memory Length Options (4 Ch / 2 Ch / 1Ch) (Number of Segments) | 500MPT option: 500 M/ 500 M / 500 M (65,535) 2000MPT option: 2000 M/ 2000 M / 2000 M (65,535) 8000MPT option: 8000 M/ 8000 M / 8000 M (65,535) |
Intersegment Time | 1 µs |
Averaging | Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps |
Enhanced Resolution (ERES) | From 12.5 to 15 bits vertical resolution |
Envelope (Extrema) | Envelope, floor, or roof for up to 1 million sweeps |
Interpolation | Linear or sin(x)/x |
|
Vertical, Horizontal, Acquisition - Digital Channels |
Maximum Input Frequency | 500 MHz |
Minimum Detectable Pulse Width | 1 ns |
Input Channels | 16 Digital channels (with WR8KHD-MSO option) |
Input Impedance (Flying Leads) | 100 kΩ || 5 pF |
Input Dynamic Range | ± 20V |
Maximum Input Voltage | ±30V Peak |
Minimum Input Voltage Swing | 400mV |
Threshold Groupings | Pod 2: D15 - D8, Pod 1: D7 - D0 |
Threshold Selections | TTL, ECL, CMOS (2.5 V, 3.3 V, 5 V), PECL, LVDS or User Defined |
Threshold Accuracy | ±(3% of threshold setting + 100mV) |
User Defined Threshold Range | ±10 V in 20 mV steps |
User Defined Hysteresis Range | 100 mV to 1.4 V in 100 mV steps |
Sample Rate | 2.5GS/s |
Record Length | Standard: 200 Mpts Any memory option: 500 Mpts |
Channel-to-Channel Skew | 350 ps |
|
Triggering System |
Max Trigger Frequency (C1-C4, Aux In, SMART Trigger) | 2.0 GHz @ ≥ 10 mV/div (minimum triggerable width 200 ps) |
Modes | Acquisition of ≤500Mpts: Normal, Auto, Single, and Stop
Acquisition of >500Mpts: Single |
Sources | Any input channel, Aux, Aux/10, Line, or Fast Edge. Slope and level unique to each source (except line trigger) |
Coupling | DC, AC, HFRej, LFRej |
Pre-trigger Delay | 0-100% of memory size (adjustable in 1% increments of 100 ns) |
Post-trigger Delay | 0-10,000 divisions in real time mode, limited at slower time/div settings |
Hold-off | From 2 ns up to 20 s or from 1 to 99,999,999 events |
Trigger and Interpolator Jitter | <0.1 ps rms (typical, software assisted), 2 ps rms (typical, hardware), |
Internal Trigger Level Range | ±3 div from center (typical) |
External Trigger Level Range | Aux (±0.4 V); Aux/10 (±4 V) |
Maximum Trigger Rate | 1,000,000 waveforms/second (in Sequence Mode, up to 4 channels) |
Trigger Sensitivity with Edge Trigger ProLink Inputs | 3 div @ < 12 GHz 1.5 div @ < 3 GHz 1.0 div @ < 200 MHz (for DC coupling, ≥ 10 mV/div, 50 Ω ) |
Trigger Sensitivity with Edge Trigger ProBus Inputs | 2.5 div @ < 1 GHz 2 div @ < 1 GHz 1.5 div @ < 500 MHz 1 div @ < 200 MHz 0.9 div @ < 10 MHz (DC, AC, and LFRej coupling, ≥ 2 mV/div, 50 Ω) |
Trigger Sensitivity with Edge Trigger (Aux Input) | 3 div @ < 2 GHz 2.5 div @ < 1 GHz 1.5 div @ < 500 MHz 1 div @ < 200 MHz 0.9 div @ < 10 MHz (DC, AC, and LFRej coupling) |
|
Trigger Types |
Edge | Triggers when signal meets slope (positive, negative, or either) and level condition. |
Width | Triggers on positive or negative glitches with selectable widths. Minimum width 500 ps, maximum width: 20 s |
Glitch | Triggers on positive or negative glitches with selectable widths. Minimum width 200 ps, maximum width: 20 s |
Window | Triggers when signal exits a window defined by adjustable thresholds |
Pattern | Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern. |
Runt | Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns. |
Slew Rate | Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns. |
Interval | Triggers on intervals selectable between 1 ns and 20 s. |
Dropout | Triggers if signal drops out for longer than selected time between 1 ns and 20 s. |
Measurement Trigger | Select from a large number of measurement parameters. Trigger on a measurement value with qualified limits. |
Multi-Stage: Qualified (Timeout or State/Edge Qualified) | Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events. (Note: event B pattern trigger cannot include analog channels). |
Triggers with Exclusion Technology | Glitch, Width, Interval, Runt, Slew Rate - Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met |
Multi-Stage: Qualified First | In Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events. (Note: event B pattern trigger cannot include analog channels). |
TriggerScan | A Trigger Trainer analyzes the waveforms, identifies normal behavior, and then sets up a large set of rare event smart trigger setups that target abnormal behavior. The trainer ‘learns’ trigger setups based on slew rates, periods, amplitudes outside of a range and then applies them sequentially. |
|
Low Speed Serial Protocol Trigger (Optional) |
Supported Protocols | 100Basse-T1, 10Base-T1SMIL-STD-1553, AudioBus, CAN, CAN FD, CAN XL, FLEXRAY, I2C, I3C, LIN, PMBus, SENT, SPI, SPMI, UART-RS232, USB2, USB4-SB, USB-PD |
|
High Speed Serial Protocol Trigger |
Data Rates | WM8KHD-8GBIT-80B-SYMBOL-TD: 1 Gb/s to 8 Gb/s, Channel 3 input only |
Pattern Length | 80 bits NRZ, eight 8b/10b symbols, 64b/66b symbol |
|
Measurement Tools |
Measurement Functionality | Display up to 12 measurement parameters together with statistics including mean, minimum, maximum, standard deviation and total number. Each occurrence of each parameter is measured and added to the statistics table. Histicons provide a fast, dynamic view of parameters and waveshape characteristics. Parameter math allows addition, subtraction, multiplication or division of two different parameters. Parameter gates define the location for measurement on the source waveform. Parameter accept criteria define allowable values based on range setting or waveform state. |
Measurement Parameters - Horizontal + Jitter | Cycles (number of), Cycle to Cycle, Delay (from trigger, 50%), Δ Delay (50%), Duty Cycle (50%, @level), Edges (number of, @level), Fall Time (90-10, @levels), Frequency (50%, @level), Half Period (@level), Hold Time (@level), N Cycle Jitter (peak-peak), Number of Points, Period (50%, @level), Δ Period (@level), Phase (@level), Rise Time (10-90, @levels), Setup (@levels), Skew (@levels), Slew Rate (@levels), Time Interval Error (@level), Time (@level), Δ Time (@level), Width (50%, @level), Δ Width (@level), X(value)@max, X(value)@min |
Measurement Parameters - Vertical | Amplitude, Base, Level@X, Maximum, Mean, Median, Minimum, Peak-to-Peak, RMS, Std. Deviation, Top |
Measurement Parameters - Pulse | Area, Base, Fall Time (90-10, 80-20, @levels), Overshoot (positive, negative), Rise Time (10-90, 80-20, @levels), Top, Width (50%) |
Measurement Parameters - Statistical (on Histograms) | Full Width (@ Half Max, @%), Amplitude, Base, Peak@MaxPopulation, Maximum, Mean, Median, Minimum, Mode, Range, RMS, Std. Deviation, Top, X(value)@Peak, Peaks (number of), Percentile, Population (@bin, total) |
|
Math Tools |
Math Functionality | Display up to 12 math functions traces (F1-F12). The easy-to-use graphical interface simplifies setup of up to two operations on each function trace, and function traces can be chained together to perform math-on-math. |
Math Operators - Basic Math | Average (summed), Average (continuous), Difference (-), Envelope, Floor, Invert (negate), Product (x), Ratio (/), Reciprocal, Rescale (with units), Roof, Sum (+) |
Math Operators - Digital (incl. with MSO models/options) | Digital AND, Digital DFlipFlop, Digital NAND, Digital NOR, Digital NOT, Digital OR, Digital XOR |
Math Operators - Filters | Enhanced resolution (to 15 bits vertical), Interpolate (cubic, quadratic, sinx/x) |
Math Operators - Frequency Analysis | FFT (power spectrum, magnitude, phase, power density, real, imaginary, magnitude squared) up to full analysis memory length. Select from Rectangular, VonHann, Hamming, FlatTop and Blackman Harris windows. |
Math Operators - Functions | Absolute value, Correlation (two waveforms), Derivative, Deskew (resample), Exp (base e), Exp (base 10), Integral, Invert (negate), Log (base e), Log (base 10), Reciprocal, Rescale (with units), Square, Square root, Zoom (identity) |
Math Operators - Other | Segment, Sparse |
|
Measurement and Math Integration |
Measurement and Math Integration | Histograms to display statistical distributions of up to 2 billion measurement parameters. Trend (datalog) of up to 1 million measurement parameters. Track (display parameter vs. time, time-correlated to acquisitions) any parameter. Persistence histogram and persistence trace (mean, range, sigma). |
|
Pass/Fail Testing |
Pass/Fail Testing | Display up to 12 pass/fail queries using a Single or Dual Parameter Comparison (compare All values, or Any value <. ≤, =, >, ≥, within limit ±Δ value or %) or Mask Test (pre-defined or user-defined mask, waveform All In, All Out, Any In, or Any Out conditions). Combine queries into a boolean expression to Pass or Fail IF All True, All False, Any True, Any False, or groups or All or Any, with following THEN Save (waveforms), Stop, Alarm, (send) Pulse, Hardcopy (send email, save screen image, save to clipboard, send to printer), or (save) LabNotebook. |
|
Display System |
Size | Color 15.6 widescreen capacitive touch screen |
Resolution | 1920 x 1080 pixels |
Number of traces | Display a maximum of 40 traces. Simultaneously display channel, zoom, memory and math traces. |
Grid Styles | Auto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y, Tandem, Quatro, Twelve, Sixteen |
Waveform Representation | Sample dots joined, or sample dots only |
|
Persistence Display |
Analog and Color-Graded Persistence | Variable saturation levels; stores each trace’s persistence data in memory |
Persistence Types | Select analog, color, or three-dimensional |
Trace Selection | Activate persistence on all or any combination of traces |
Persistence Aging | Select from 500 ms to infinity |
Sweep Display Modes | All accumulated, or all accumulated with last trace highlighted |
|
Zoom Expansion Traces |
Zoom Expansion Traces | Display up to 12 Zoom and 12 Math/Zoom traces |
|
Internal Waveform Memory |
Internal Waveform Memory | 12 active waveform memory traces (M1-M12) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity. |
|
Setup Storage |
Front Panel and Instrument Status | Store to the internal hard drive, over the network, or to a USB-connected peripheral device. |
|
Automatic Setup |
Auto Setup | Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals |
Find Vertical Scale | Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range |
|
Calibration |
Auto Calibration | Ensures specified DC and timing accuracy is maintained for 1 year minimum. |
|
Processor/CPU |
Type | Intel Core i7-12700E or better |
Processor Memory | 64 GB standard |
Operating System | Microsoft Windows® 10 |
Oscilloscope Operating Software | Teledyne LeCroy MAUI™ with OneTouch |
Real Time Clock | Date and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks. |
|
Connectivity |
Ethernet Port | Supports 2.5GBaseT Ethernet interface (RJ45 port) |
USB Host Ports | 4 side USB 3.2 Gen2x1 Type-A ports, 2 front panel USB 3.2 Gen1x1 Type-A ports, 1 front panel USB 3.2 Gen1x1 Type-C port support Windows compatible devices |
USB Device Port | 1 port - USBTMC over USB 3.1 Gen1 |
GPIB Port (optional) | Supports IEEE - 488.2 (External) |
External Monitor Port | 2 x HDMI, supports up to 4096x2304 1 x DisplayPort, supports up to 4096x2304 |
Remote Control | Via Windows Automation, or via LeCroy Remote Command Set |
Network Communication Standard | VXI-11 or VICP, LXI Class C (v1.2) Compliant |
Peripheral Bus | Teledyne LeCroy LBUS standard Supports HDA125 high-speed digital analyzer only |
|
Auxiliary Input |
Signal Types | For External Trigger Input |
Coupling | 50 Ω: DC; 1 MΩ: AC, DC, GND |
Max. Input Voltage | 50 Ω 5V RMS, +/- 10V Peak
1 MΩ 400 V max (Peak DC+AC) |
|
Auxiliary Output |
Signal Types | Select from calibrator, control signals or Off |
Output Signal | 500 Hz-5 MHz square wave or DC level; 0.0 to 500 mV into 50 Ω (0-1 V into 1 MΩ) |
Control Signals | Trigger enabled, trigger out, pass/fail status, off |
Connector Type | BNC, located on front |
|
Probes |
Probing System | Probus and ProLink. Automatically detects and supports a variety of compatible probes. |
Probes
| Qty. (4) ÷10 Passive Probes |
Scale Factors | Automatically or manually selected depending on probe used |
Calibration Output | Cal Output: 1kHz square wave, 1Vp-p (typical), output to probe hook. Fast Edge output: 5MHz square wave, 400mVp-p (typical), 40ps rise time, output to SMA connector, AC Coupled. |
|
Power Requirements |
Voltage | 90 to 264 Vrms, 47 to 63 Hz |
Nominal Power Consumption | 750 W |
Max. Power Consumption | 850 W |
|
Environmental |
Temperature (Operating) | 5 °C to 40 °C |
Temperature (Non-Operating) | -20 °C to +60 °C |
Humidity (Operating) | Maximum RH 80% (non-condensing) up to 31 °C decreasing linearly to RH 50% at 40 °C |
Humidity (Non-Operating) | 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F |
Altitude (Operating) | Up to 10,000 ft (3,048 m) at or below 30 °C |
Altitude (Non-Operating) | Up to 40,000 ft. (12,192 m) |
Random Vibration (Operating) | 0.5 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes |
Random Vibration (Non-Operating) | 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes |
Functional Shock | 20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total |
|
Size and Weight |
Dimensions (HWD) | With handles and protective cover: 15H x 20.75W x 16.2D (381 x 527 x 410 mm) Without handles and protective cover: 15H x 17.5W x 15.8D (381 x 445 x 400 mm) |
Weight | 48 lbs (21.8 kg) |
Shipping Weight | 76 lbs (34.5 kg) |
|
Certifications |
CE Certification UL and cUL Listing | Conforms to EN61326-1 (for EMC); EN61010-1, EN61010-2-030 (for Safety); EN63000 (for RoHS) Conforms to UL61010-1 (3rd Edition), UL61010-2-030 (2nd Edition) and CSA C22.2 No.61010-1-12 Conforms to UK SI 2016 No. 1091 (for EMC), UK SI 2016 No. 1101 (for Safety) and UK SI 2012 No. 3032 (for RoHS) |
|
Warranty and Service |
Warranty and Service | 3-year warranty; calibration recommended annually. Optional service programs include extended warranty, upgrades, and calibration services. |
|