Products
Oscilloscopes
HDO6034B Oscilloscope

HDO6034B

350 MHz, 4 Ch, 12 bits, 10 GS/s, 50 Mpts/Ch High Definition Oscilloscope with 15.6" Display


  • product line tab
  • overview tab
  • specs tab
  • options tab
  • probes tab
HDO6034B   (350 MHz Bandwidth, 4 Input Channels, 50 Mpts/ch, 10 GS/s)
Quick Specs
Sample Rate10 GS/s on 4 Ch with ESR
Maximum Acquisition Memory250 Mpts (4 Ch operation)
Input Channels4
Vertical Resolution12-bits
HDO6054B   (500 MHz Bandwidth, 4 Input Channels, 50 Mpts/ch, 10 GS/s)
Quick Specs
Sample Rate10 GS/s on 4 Ch with ESR
Maximum Acquisition Memory250 Mpts (4 Ch operation)
Input Channels4
Vertical Resolution12-bits
HDO6104B   (1 GHz Bandwidth, 4 Input Channels, 50 Mpts/ch, 10 GS/s)
Quick Specs
Sample Rate10 GS/s on 4 Ch with ESR
Maximum Acquisition Memory250 Mpts (4 Ch operation)
Input Channels4
Vertical Resolution12-bits
HDO6054B-MS   (500 MHz Bandwidth, 4+16 Input Channels, 50 Mpts/ch, 10 GS/s)
Quick Specs
Sample Rate10 GS/s on 4 Ch with ESR
Maximum Acquisition Memory250 Mpts (4 Ch operation)
Input Channels4
Vertical Resolution12-bits
HDO6104B-MS   (1 GHz Bandwidth, 4+16 Input Channels, 50 Mpts/ch, 10 GS/s)
Quick Specs
Sample Rate10 GS/s on 4 Ch with ESR
Maximum Acquisition Memory250 Mpts (4 Ch operation)
Input Channels4
Vertical Resolution12-bits
Check up to three models.
Key Features
  • Highest resolution - 12 bits all the time
  • Bigger Display, smaller footprint, most bench space
  • More capability, increased productivity
  • Zone Trigger – Simple Triggering for Complex Signals

 

Highest Resolution - HD4096 High Definition Technology,12 Bits All the Time

Teledyne LeCroy high definition 12-bit oscilloscopes use unique HD4096 technology to provide superior and uncompromised measurement performance. HD4096 technology provides the highest resolution and lowest noise at full bandwidth—12 bits all the time with no compromise.

 

Bigger Display, Smallest Footprint, More Bench Space
  • 15.6" display with 1920x1080 resolution
  • Sleekest instrument compared to competition. 25% less deep.
  • Occupies lesser bench space compared to competition

 

More Capability, Increased Productivity

Increase productivity with specialized tools

  • MAUI Studio
  • Spectrum Analysis
  • QualiPHY Compliance Testing

 

Vertical - Analog Channels

Analog Bandwidth (Max) 350 MHz
Bandwidth 350 MHz
Analog Bandwidth @ 50 Ω (-3 dB) (ProBus Input) 350 MHz
(≥1 mV/div)
Analog Bandwidth @ 1 MΩ (-3 dB) (ProBus Input) 350 MHz (typical)
Rise Time (10-90%, 50 Ω) 1 ns (typical)
Rise Time (20-80%, 50 Ω) 700 ps (typical)
Input Channels 4
Vertical Resolution 12 bits; up to 15 bits with enhanced resolution (ERES)
Effective Number of Bits (ENOB) 8.7 bits
Vertical Noise Floor (1 mV/div) 85 uVrms
Vertical Noise Floor (2 mV/div) 85 uVrms
Vertical Noise Floor (5 mV/div) 90 uVrms
Vertical Noise Floor (10 mV/div) 95 uVrms
Vertical Noise Floor (20 mV/div) 110 uVrms
Vertical Noise Floor (50 mV/div) 210 uVrms
Vertical Noise Floor (100 mV/div) 360 uVrms
Vertical Noise Floor (200 mV/div) 1.10 mVrms
Vertical Noise Floor (500 mV/div) 2.10 mVrms
Vertical Noise Floor (1 V/div) 3.70 mVrms
Sensitivity 50 Ω: 1 mV-1 V/div, fully variable;
1 MΩ: 1 mV-10 V/div, fully variable
DC Vertical Gain Accuracy (Gain Component of DC Accuracy) ±(0.5%) FS, offset at 0 V
Channel-Channel Isolation DC-200 MHz: 60 dB (>1000:1),
200 MHz up to rated BW: 50 dB (>300:1),
(For any two input channels, same v/div settings, typical)
Offset Range 50 Ω
±1.6 V @ 1 mV - 4.95 mV/div
±4 V @ 5 mV - 9.9 mV/div
±8 V @ 10 mV - 19.8 mV/div
±10 V @ 20 mV - 1 V/div

1 MΩ
±1.6 V @ 1 mV - 4.95 mV/div
±4 V @ 5 mV - 9.9 mV/div
±8 V @ 10 mV - 19.8 mV/div
±16 V @ 20 mV - 100 mV/div
±80 V @ 102 mV - 198 mV/div
±160 V @ 200 mV - 1 V/div
±400 V @ 1.02 V - 10 V/div
DC Vertical Offset Accuracy ±(1.0% of offset setting + 0.5%FS + 0.02% of max offset + 1mV)
Maximum Input Voltage 50 Ω: 5 Vrms,
1 MΩ: 400 V max
(DC + Peak AC ≤ 10 kHz)
Input Coupling 1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Input Impedance 1 MΩ ± 2.0% || 15 pF,
50 Ω ± 2.0%
Bandwidth Limiters 20MHz, 200MHz
Rescaling Length: meters, inches, feet, yards, miles; Mass: grams, slugs; Temperature: celsius, fahrenheit, kelvin; Angle: radian, arcdegr, arcmin, arcsec, cycles, revolutions, turns; Velocity: m/s, in/s, ft/s, yd/s, miles/s; Acceleration: m/s2, in/s2, ft/s2, g0; Volume: liters, cubic meters, cubic inches, cubic feet, cubic yards; Force (Weight): newton, grain, ounce, pound; Pressure: pascal, bar, atmosphere (technical), atmosphere (standard), torr, psi; Electrical: volts, amps, watts, volt-amperes, volt-amperes reactive, farad, coulomb, ohm, siemen, volt/meter, coulomb/m2, farad/meter, siemen/meter, power factor; Magnetic: weber, tesla, henry, amp/meter, henry/meter; Energy: joule, Btu, calorie; Rotating Machine: radian/second, frequency, revolution/second, revolution/minute, N m, lb-ft, lb-in, oz-in, watt, horsepower; Other: %.
 

Horizontal - Analog Channels

Timebases Internal timebase common to 4 input channels; an external clock may be applied at the auxiliary input
Acquisition Modes Real-time, Roll, Random Interleaved Sampling (RIS), Sequence
Time/Division Range 20 ps/div - 5 ks/div with standard memory (up to 10 ks/div with -L memory, 25 ks/div with -XL memory);
RIS available at ≤ 10 ns/div; Roll Mode available at ≥ 100 ms/div and ≤ 5 MS/s
Clock Accuracy +/-2.5ppm + 1.0ppm/year from calibration
Sample Clock Jitter up to 10ms Acquired Time Range:
280fsrms (Internal Timebase Reference)
Delta Time Measurement Accuracy \sqrt{2}*\sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2) (RMS)+(clock accuracy*reading)(seconds)
Jitter Measurement Floor \sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2\; seconds\; rms\; (TIE)}
Jitter Between Channels 2psrms (TIE, typical)
Channel-Channel Deskew Range ±9 x time/div. setting, 100 ms max., each channel
External Timebase Reference (Input) 10MHz +/-25ppm at 0 to 10dBm into 50 Ohms
External Timebase Reference (Output) 10MHz, 2.0 dBm +/-1.5 dBm, sinewave synchronized to reference being used (internal or external reference)
External Clock DC to 100 MHz; (50 Ω/1 MΩ), EXT BNC input, Minimum rise time and amplitude requirements apply at low frequencies.
 

Acquisition - Analog Channels

Sample Rate (Single-shot) 10 GS/s on 4 Ch with Enhanced Sample Rate
Sample Rate (Repetitive) 125 GS/s for repetitive signals (20 ps/div to 10 ns/div)
Memory Length (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
50M / 50M / 50M
(30,000)
Memory Length Options (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
L- Option:
100M / 100M / 100M
(60,000)
XL - Option:
250M / 250M / 250M
(65,000)
Intersegment Time 1.25 µs
Averaging Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
Enhanced Resolution (ERES) From 12.5 to 15 bits vertical resolution
Envelope (Extrema) Envelope, floor, or roof for up to 1 million sweeps
Interpolation Linear or Sin x/x (2 pt and 4 pt); 5 or 10 GS/s Enhanced Sample Rate defaults to 2pt or 4pt Sin x/x respectively
 

Triggering System

Max Trigger Frequency (C1-C4, Aux In, SMART Trigger) 350MHz
Modes Normal, Auto, Single, and Stop
Sources Any input channel, Ext, Ext/10, or line; slope and level unique to each source (except line trigger)
Coupling DC, AC, HFRej, LFRej
Pre-trigger Delay 0-100% of memory size (adjustable in 1% increments of 100 ns)
Post-trigger Delay 0-10,000 Divisions in real time mode, limited at slower time/div settings or in roll mode
Hold-off From 2 ns up to 20 s or from 1 to 99,999,999 events
Trigger and Interpolator Jitter ≤ 4 psrms (typical)
<0.1 ps RMS (typical, software assisted)
Internal Trigger Level Range ±4.1 div from center (typical)
External Trigger Level Range Ext (±0.4 V); Ext/10 (±4 V)
Maximum Trigger Rate 800,000 waveforms/second (in Sequence Mode, up to 4 channels)
Trigger Sensitivity with Edge Trigger ProBus Inputs 2 div @ < 350 MHz
1 div @ < 200 MHz
0.9 div @ < 10 MHz
(DC, AC, and LFRej coupling, ≥ 2 mV/div, 50 Ω)
Trigger Sensitivity with Edge Trigger (Aux Input) 2 div @ < 350 MHz
1 div @ < 200 MHz
0.9 div @ < 10 MHz
(DC, AC, and LFRej coupling)
 

Trigger Types

Edge Triggers when signal meets slope (positive, negative, or either) and level condition.
Width Triggers on positive or negative glitches with selectable widths.
minimum width 1.5ns, Maximum Width: 20s
Glitch Triggers on positive or negative glitches with selectable widths. minimum width 1.5ns, Maximum Width: 20s
Window Triggers when signal exits a window defined by adjustable thresholds
Pattern Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern.
TV-Composite Video Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative).
Runt Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew Rate Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
Interval Triggers on intervals selectable between 1 ns and 20 s.
Dropout Triggers if signal drops out for longer than selected time between 1 ns and 20 s.
Measurement Trigger Select from a large number of measurement parameters trigger on a measurement value with qualified limits. Can be used as only trigger or last event in a Cascade Trigger.
Multi-Stage: Qualified (Timeout or State/Edge Qualified) Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events.
Triggers with Exclusion Technology Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
Multi-Stage: Qualified First In Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events.
Multi-Stage: Cascade (Sequence) Trigger, Capability Arm on A event, then Trigger on B event. Or Arm on A event, then Qualify on B event, and Trigger on C event.
Multi-Stage: Cascade (Sequence) Trigger, Types Cascade A then B: Edge, Window, Pattern (Logic) Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage B only.
Cascade A then B then C (Measurement): Edge, Window, Pattern (Logic), Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage C only.
Cascade A then B then C: Edge, Window, Pattern (Logic)
Multi-Stage: Cascade (Sequence) Trigger, Holdoff Holdoff between A and B or B and C is selectable by time or number of events.
Measurement trigger selection as the last stage in a Cascade precludes a holdoff setting between the prior stage and the last stage.
TriggerScan A Trigger Trainer analyzes the waveforms, identifies normal behavior, and then sets up a large set of rare event smart trigger setups that target abnormal behavior. The trainer ‘learns’ trigger setups based on slew rates, periods, amplitudes outside of a range and then applies them sequentially.
 

Low Speed Serial Protocol Trigger (Optional)

Supported Protocols I2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN1.1, CAN2.0, CAN FD, LIN, FlexRay, MIL-STD-1553, AudioBus (I2S, LJ, RJ, TDM), USB1.x/2.0
 

Measurement Tools

Measurement Functionality Display up to 8 measurement parameters together with statistics, including mean, minimum, maximum, standard deviation, and total number. Each occurrence of each parameter is measured and added to the statistics table. Histicons provide a fast, dynamic view of parameters and waveshape characteristics. Parameter math allows addition, subtraction, multiplication, or division of two different parameters. Parameter gates define the location for measurement on the source waveform. Parameter accept criteria define allowable values based on range setting or waveform state.
Measurement Parameters - Horizontal + Jitter Cycles (number of), Delay (from trigger, 50%), Δ Delay (50%), Duty Cycle (50%, @level), Edges (number of, @level), Fall Time (90-10, @levels), Frequency (50%, @level), Half Period (@level), Hold Time (@level), N Cycle Jitter (peak-peak), Number of Points, Period (50%, @level), Δ Period (@level), Phase (@level), Rise Time (10-90, @levels), Setup (@levels), Skew (@levels), Slew Rate (@levels), Time Interval Error (@level), Time (@level), Δ Time (@level), Width (50%, @level), Δ Width (@level), X(value)@max, X(value)@min
Measurement Parameters - Vertical Amplitude, Base, Level@X, Maximum, Mean, Median, Minimum, Peak-to-Peak, RMS, Std. Deviation, Top.
Measurement Parameters - Pulse Area, Base, Fall Time (90-10, 80-20, @levels), Overshoot (positive, negative), Rise Time (10-90, 80-20, @levels), Top, Width (50%)
Measurement Parameters - Statistical (on Histograms) Full Width (@ Half Max, @ %), Amplitude, Base, Peak @ Max Population, Maximum, Mean, Median, Minimum, Mode, Range, RMS, Std. Deviation, Top, X(value)@Peak, Peaks (number of), Percentile, Population (@bin, total)
 

Math Tools

Math Functionality Display up to 8 math functions traces (F1-F8). The easy-to-use graphical interface simplifies setup of up to two operations on each function trace, and function traces can be chained together to perform math-on-math.
Math Operators - Basic Math Average (summed), Average (continuous), Difference (-), Envelope, Floor, Invert (negate), Product (x), Ratio (/), Reciprocal, Rescale (with units), Roof, Sum (+).
Math Operators - Filters Enhanced resolution (to 15 bits vertical), Interpolate (cubic, quadratic, sinx/x), (SinX)/x.
Math Operators - Frequency Analysis FFT (power spectrum, magnitude, phase, power density, real, imaginary, magnitude squared), up to full record length. Select from Rectangular, VonHann, Hamming, FlatTop and Blackman Harris windows.
Math Operators - Functions Absolute value, Correlation (two waveforms), Derivative, Deskew (resample), Exp (base e), Exp (base 10), Integral, Invert (negate), Log (base e), Log (base 10), Reciprocal, Rescale (with units), Square, Square root, Zoom (identity).
Math Operators - Other Segment, Sparse
 

Measurement and Math Integration

Measurement and Math Integration Histograms to display statistical distributions of up to 2 billion measurement parameters. Trend (datalog) of up to 1 million measurement parameters. Track (display parameter vs. time, time-correlated to acquisitions) any parameter. Persistence histogram and persistence trace (mean, range, sigma)
 

Pass/Fail Testing

Pass/Fail Testing Display up to 8 pass/fail queries using a Single or Dual Parameter Comparison (compare All values, or Any value <. ≤, =, >, ≥, within limit ±Δ value or %) or Mask Test (pre-defined or user-defined mask, waveform All In, All Out, Any In, or Any Out conditions). Combine queries into a boolean expression to Pass or Fail IF All True, All False, Any True, Any False, or groups or All or Any, with following THEN Save (waveforms), Stop, Alarm, (send) Pulse, Hardcopy (send email, save screen image, save to clipboard, send to printer), or (save) LabNotebook.
 

Display System

Size Color 15.6 widescreen capacitive touch screen
Resolution 1920 x 1080 pixels
Number of traces Display a maximum of 16 traces. Simultaneously display channel, zoom, memory and math traces.
Grid Styles Auto, Single, Dual, Quad, Octal, Tandem, Quattro, Twelve, Sixteen, X-Y, Single+X-Y, Dual+X-Y
Waveform Representation Sample dots joined, or sample dots only
 

Integrated Second Display

Size Supports touch screen integration of user-supplied second display with split-grid capability.
(Note: touch screen driver for second display may not be a Fujitsu driver)
Resolution 4096 x 2304 pixels
 

Persistence Display

Analog and Color-Graded Persistence Variable saturation levels; stores each trace’s persistence data in memory
Persistence Types Select analog, color, or three-dimensional
Trace Selection Activate persistence on all or any combination of traces
Persistence Aging Select from 500 ms to infinity
Sweep Display Modes All accumulated, or all accumulated with last trace highlighted
 

Zoom Expansion Traces

Zoom Expansion Traces Display up to 8 Zoom and 8 Math/Zoom traces
 

Internal Waveform Memory

Internal Waveform Memory 4 active waveform memory traces (M1-M4) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.
 

Setup Storage

Front Panel and Instrument Status Store to the internal hard drive, over the network, or to a USB-connected peripheral device.
 

Automatic Setup

Auto Setup Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical Scale Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range
 

Calibration

Calibration Stability Calibration ensured within +/-5°C operating temperature. Manual calibration may be invoked if outside this temperature range.
 

Processor/CPU

Type Intel® i5-6500 Quad Core, 3.2 GHz (or better)
Processor Memory 16 GB standard
Operating System Microsoft Windows® 10
Oscilloscope Operating Software Teledyne LeCroy MAUI™ with OneTouch
Real Time Clock Date and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks.
 

Connectivity

Ethernet Port Supports 2 10/100/1000BaseT Ethernet interface (RJ45 ports)
USB Host Ports 4 side USB 3.1 Gen1 ports, 2 front USB 3.1 Gen1 ports
USB Device Port 1 USBTMC port
GPIB Port (optional) Supports IEEE - 488.2 (External)
External Monitor Port 1 x DisplayPort, supports up to 4096x2304 @ 24 Hz
1 x HDMI, supports up to 4096x2304 @ 60 Hz
Remote Control Via Windows Automation, or via LeCroy Remote Command Set
 

Auxiliary Input

Signal Types Select External Trigger or External Clock Input on the front panel
Coupling 50 Ω: DC; 1 MΩ: AC, DC, GND
Max. Input Voltage 50 Ω
5V RMS, +/- 10V Peak

1 MΩ
400 V max (Peak DC+AC)
 

Auxiliary Output

Signal Types Select from control signals or Off
Output Signal 500 Hz-1 MHz square wave or DC level; 50 mV-1 V into 1 MΩ
Control Signals Trigger enabled, trigger out, pass/fail status, off
Connector Type BNC, located on rear panel
 

Probes

Probing System ProBus. Automatically detects and supports a variety of compatible probes
Probes Qty. (4) ÷10 Passive Probes
Scale Factors Automatically or manually selected depending on probe used
Calibration Output Default is 1kHz square wave, 1Vp-p (typical), output to probe hook. Settable from 250 Hz to 1 MHz square wave; 50 mV to 1.0V.
 

Power Requirements

Voltage 100 - 240 VAC ±10% at 47 - 63 Hz
100 - 240 VAC ±10% at 380 - 420 Hz
Automatic AC Voltage Selection
Installation Category 300 V CAT II
Nominal Power Consumption 220 W / 220 VA
Max. Power Consumption 320 W / 320 VA (with all PC peripherals and active probes connected to 4 channels)
 

Environmental

Temperature (Operating) +5 °C to +40 °C
Temperature (Non-Operating) -20 °C to +60 °C
Humidity (Operating) 5% to 80% relative humidity (non-condensing) up to +31 °C.
Upper limit derates to 50% relative humidity (non-condensing) at +40 °C.
Humidity (Non-Operating) 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating) Up to 10,000 ft. (3048 m) at or below +30 °C
Altitude (Non-Operating) Up to 40,000 ft. (12,192 m)
Random Vibration (Operating) 0.31 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Random Vibration (Non-Operating) 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Functional Shock 30 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
 

Size and Weight

Dimensions (HWD) 13.8”H x 17.5”W x 6.7”D (352 mm x 445 mm x 170 mm)
Weight 21 lbs (9.8 kg)
Shipping Weight 33.6 lbs (15.2 kg)
 

Certifications

CE Certification
UL and cUL Listing
CE Compliant, UL and cUL listed; conforms to
UL 61010-1 (3rd Edition), UL 61010-2-030 (1st Edition)
CAN/CSA C22.2 No. 61010-1-12,
 

Warranty and Service

Warranty and Service 3-year warranty; calibration recommended annually.
Optional service programs include extended warranty, upgrades, and calibration services.
 

Memory Options

HDO6KB-L
100 Mpt/Ch Memory Option for HDO6000B
HDO6KB-XL
250 Mpt/Ch Memory Option for HDO6000B

Computer Upgrade

HDO6KB-SSD-02
Replacement Removable Solid State Drive for HDO6000B

Remote Control/Network Options

USB2-GPIB
External USB 2.0 to GPIB IEEE 488.2 adapter

Power Analysis Software

HDO6K-POWER-DEVICE
Power Device Analysis Option for HDO6000
HDO6K-THREEPHASEHARMONICS
3-phase Harmonics Calculation Option for HDO6000 (only available with HDO6K-THREEPHASEPOWER)
HDO6k-DIG-PWR-MGMT
Digital Power Management Analysis Software Option for HDO6000
HDO6K-THREEPHASEPOWER
3-phase Power Analysis software for HDO6000
HDO6K-THREEPHASEDQ0
3-phase dq0 Transform option for HDO6000
HDO6K-THREEPHASEVECTOR
3-phase Vector Display option for HDO6000
HDO6K-PWR
Power Analysis Option for HDO6000

Serial Trigger and Decode

HDO6K-100BASE-T1 TDMP
100Base-T1 Trigger, Decode, Measure/Graph, and Physical Layer Option for HDO6000
HDO6K-QSPI TD
QSPI (Simple Data, Dual-, Quad-SPI) Trigger and Decode Option for HDO6000-Serie
HDO6K-DPAUX TD
DisplayPort AUX Trigger and Decode Option for HDO6000
HDO6K-DPAUX TDMP
DisplayPort AUX Trigger, Decode, Measure/Graph, and Physical Layer Option for HDO6000
HDO6K-100Base-T1bus TD
100Base-T1 Trigger and Decode Option for HDO6000
HDO6K-1553 TD
MIL-STD-1553 Trigger and Decode Option for HDO6000
HDO6K-USBPD TD
USB-PD Trigger and Decode Option for HDO6000
HDO6K-10BASE-T1S TDME
10Base-T1S Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-1553 TDME
MIL-STD-1553 Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-USBPD TDMP
USB-PD Trigger, Decode, Measure/Graph, and Physical Layer Option for HDO6000
HDO6K-DPAUX DMP
DisplayPort AUX Decode, Measure/Graph, and Physical Layer Option for HDO6000 Limited Availability
HDO6K-10BASE-T1S TD
10Base-T1S Trigger and Decode Option for HDO6000
HDO6K-USB4SB TDMP
USB4-SB Trigger, Decode, Measure/Graph, and PHY Measurement Option for HDO6000
HDO6k-ARINC429BUS DME SYMBOLIC
ARINC 429 Bus Symbolic Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-USB4SB TD
USB4-SB Trigger and DecodeOption for HDO6000
HDO6K-ARINC429BUS Dsymbolic
ARINC 429 Bus Symbolic Decode option for HDO6000
HDO6K-DPAUX D
DisplayPort AUX Decode Option for HDO6000 Limited Availability
HDO6K-Audiobus TD
AudioBus trigger and decode option for HDO6000
HDO6K-Audiobus TDG
AudioBus trigger, decode, and graph option for HDO6000
HDO6K-CAN FDbus TD
CAN and CAN FD Trigger and Decode Option for HDO6000
HDO6K-CAN FDBUS TDME SYMBOLIC
CAN and CAN FD Symbolic Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-CAN XL TD
CAN/ CAN FD/ CAN XL Trigger and Decode Option for HDO6000
HDO6K-CAN XL TDME SYMBOLIC
CAN /CAN FD/ CAN XL Symbolic Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-DigRF3Gbus D
DigRF 3G Bus Decode option for HDO6000
HDO6K-DigRFv4bus D
DigRF V4 Bus Decode option for HDO6000
HDO6K-DPHYbus D
MIPI D-PHY CSI-2, DSI Bus Decode option for HDO6000
HDO6K-EMB TD
Bundle: Includes I2C, SPI, UART-RS232 Trigger and Decode Options for HDO6000
HDO6K-EMB TDME
Bundle: Incl. I2C, SPI, UART-RS232 Trigger, Decode, Measure/Graph, and Eye Diagram Opt. for HDO6000
HDO6K-EMB TDME
Bundle: Incl. I2C, SPI, UART-RS232 Trigger, Decode, Measure/Graph, and Eye Diagram Opt. for HDO6000
HDO6K-ENETbus D
ENET Bus Decode Option for HDO6000
HDO6K-FlexRaybus TD
FlexRay Trigger and Decode Option for HDO6000
HDO6K-FLEXRAYBUS TDMP
FlexRay Trigger, Decode, Measure/Graph and Physical Layer Option for HDO6000
HDO6K-I2Cbus TD
I2C Trigger and Decode Option for HDO6000
HDO6K-I2CBUS TDME
I2C Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6k-I3Cbus TD
I3C Trigger and Decode Option for HDO6000 (I2C supported)
HDO6k-I3Cbus TDME
I3C Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000 (I2C supported)
HDO6K-LINbus TD
LIN Trigger and Decode Option for HDO6000
HDO6K-LINBUS TDME
LIN Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-Manchesterbus D
Manchester Bus Decode Option for HDO6000
HDO6K-MDIObus D
MDIO Decode for HDO6000 Series
HDO6K-NRZbus D
NRZ Bus Decode Option for HDO6000
HDO6K-PMBus TD
PMBus Trigger and Decode Option for HDO6000
HDO6K-PMBus TDME
PMBus Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-SENTbus TD
SENT Trigger and Decode Option for HDO6000
HDO6K-SENTbus TDME
SENT Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-SMBus TD
SMBus Trigger and Decode Option for HDO6000
HDO6K-SMBus TDME
SMBus Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-SpaceWirebus D
SpaceWire Decode Option for HDO6K series
HDO6K-SPIbus TD
SPI Trigger and Decode Option for HDO6000
HDO6K-SPIBUS TDME
SPI Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6k-SPMIbus TD
SPMI Trigger and Decode Option for HDO6000
HDO6k-SPMIbus TDME
SPMI Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-UART-RS232bus TD
UART-RS232 Trigger and Decode Option for HDO6000
HDO6K-UART-RS232BUS TDME
UART-RS232 Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000
HDO6K-USB2-HSICbus D
USB 2.0 HSIC Decode Option for HDO6000
HDO6K-USB2bus TD
USB 2.0 Trigger and Decode Option for HDO6000
HDO6k-USB2BUS TDME
USB 2.0 Trigger, Decode, Measure/Graph, and Eye Diagram Option for HDO6000

Jitter Analysis Software

HDO6K-CLOCK-X-PRO
Clock Expert Jitter Analysis Framework with SSC, Phase Noise, and Accumulated Jitter Analysis
HDO6K-CLOCK-X
Clock Expert Jitter Analysis Framework
HDO6K-JITKIT
Clock, clock-data Jitter Analysis and views of time, statistical, spectral, and jitter overlay

Digital Filtering Software

HDO6K-DFP2
Digital Filter Software Package for HDO6000

Serial Data Compliance

HDO6K-ET-PMT
Electrical Telecom Mask Test Package
QPHY-10Base-T1L
QualiPHY Enabled 10Base-T1L (Industrial Ethernet) Compliance Software Option
QPHY-10Base-T1S
QualiPHY Enabled 10Base-T1S (Automotive Ethernet) Compliance Software Option
QPHY-USB
QualiPHY Enabled USB 2.0 Compliance Software Option

Serial Data Analysis

HDO6K-SDAX-NRZ
NRZ Serial Data Analysis Framework, Eye,Jitter, Noise and Crosstalk Measurements
HDO6K-SDAX-PAM
PAM Serial Data Expert Analysis Framework, Eye,Jitter and Noise Measurements
HDO6K-SDM
Serial Data Mask Software Package for HDO6000

Other Software Options

HDO6K-ZONETRIGGER
Zone Trigger option for HDO6000
HDO6K-SPECTRUM-1
Spectrum Analyzer for HDO6000 - 1 trace
HDO6K-EMC
EMC Pulse Parameter Software Package for HDO6000
HDO6K-Q-SCAPE
Q-Scape Multi-tab Display Option for HDO6000
HDO6K-SPECTRUM-PRO-2R
Spectrum Analyzer for HDO6000 - 2 traces + reference
HDO6K-XDEV
Advanced Customization Option for HDO6000
MAUI Studio Pro
MAUI Studio Pro Offline Remote and PC Analysis Software License

Miscellaneous

HDO6KB-RACKMOUNT
Rackmount kit for HDO6000B
WPHD-CARRYCASE
WavePro HD Carrying Case

Serial Data Test Fixtures

TF-AUTO-ENET
Automotive Ethernet Breakout Test Fixture for 100Base-T1 and 1000Base-T1 Debug
TF-AUTO-ENET-SMA
4 pack of SMA Connector boards for TF-AUTO-ENET
TF-AUTO-HMTD
Test Fixture HMTD-Connector (m) to SMA (f)
TF-AUTO-MATENET
Test Fixture MATEnet-Connector (m) to SMA (f)
TF-AUTO-MINI50
Test Fixture Mini-50-Connector (m) to SMA (f)
TF-USB-C-HS
USB4 High-speed and Sideband Test Coupon Fixture
TF-USB-C-SB
USB4 Sideband Test Coupon Fixture

Active Voltage Probes

ZS1500
1.5 GHz, 0.9 pF, 1 MOhm Active Voltage Probe
ZS1000
1 GHz, 0.9 pF, 1 MOhm Active Voltage Probe

Differential Probes (<= 1.5 GHz)

AP033
500 MHz Differential Probe
ZD200
200 MHz, 3.5 pF, 1 MOhm Active Differential Probe, ±20 V Limited Availability
ZD500
500 MHz, 1.0 pF Active Differential Probe, ±8 V
ZD1000
1 GHz, 1.0 pF Active Differential Probe, ±8 V
ZD1500
1.5 GHz, 1.0 pF Active Differential Probe, ±8 V

Current Probes

CP150
150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 2 meter cable Limited Availability
CP500
500 A, 2 MHz Current Probe - AC/DC, 500 A rms, 700 A Peak Pulse, 6 meter cable
CP030
30A, 50 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable Limited Availability
CP031
30A, 100 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP030A
30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable Limited Availability
CP031A
30A, 100 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CA10
Programmable Current Sensor to ProBus Adapter for use with third party current sensors
CP030-3M
30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 3 meter cable Limited Availability
CP150-6M
150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 meter cable Limited Availability
DCS025
Deskew Calibration Source for Teledyne LeCroy current probes
CP150B
150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 2 meter cable
CP030B
30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable

High Voltage Passive Probes

HVP120
6kV High Voltage Passive Probe, 400 MHz
PPE6KV-A
6kV High Voltage Passive Probe, 500 MHz

Passive Probes

PP018-1
500 MHz Passive Probe for HDO, 10:1, 10 MOhm
PP023-1
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP026-1
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm

High Voltage Differential Probes

AP031
700 V, 25 MHz High-Voltage Differential Probe (÷10, ÷100) Limited Availability
HVD3102A
1kV, 25 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3102A-NOACC
1kV, 25 MHz High Voltage Differential Probe without tip Accessories and with Auto Zero Disconnect
HVD3106A
1kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3106A-NOACC
1kV, 120 MHz High Voltage Differential Probe without tip Accessories and with Auto Zero Disconnect
HVD3106A-6M
1kV, 80 MHz High Voltage Differential Probe with 6m cable and Auto Zero Disconnect
HVD3206A
2kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3206A-6M
2kV, 80 MHz High Voltage Differential Probe with 6m cable and Auto Zero Disconnect
HVD3605A
6kV, 100 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3220
2kV, 400 MHz High Voltage Differential Probe

Probe Parts and Kits

PACC-ZD001
Y lead Adapter for ZD differential probes - Qty 1
PACC-ZD002
Solder-in lead for ZD differential probe - QTY 2
PACC-ZD003
Long spring ground for ZD differential probe - QTY 2
PACC-ZD004
Tip saver for ZD differential probe - QTY 2
PACC-ZD005
Swivel tip adapter for ZD differential probe - QTY 1
PACC-ZD006
Small IC adapter for ZD differential probe - QTY 2
PK111
Replacement Accessory kit for ZD500, ZD1000, and ZD1500
PKIT4-5MM-101
Standard Accessory Replacement Kit for PP017/PP018

Probe Adapters

TPA10
TekProbe to ProBus Probe Adapter

Active Voltage Rail Probe

RP4030
Power/Voltage Rail Probe. 4 GHz bandwidth, 1.2x attenuation, +/-30V offset, +/-800mV Includes a complete set of solder-in leads, coaxial cables, and PCB mounts. Limited Availability
RP4000-MCX-LEAD-SI
Qty 3 MCX 4 GHz solder-in lead accessories (additional to those supplied with rail probe) 18cm long
RP4000-BROWSER
RP2060/RP4060 Browser Tip accessory. Includes 0 Ohm (1x), 450 Ohm (10x) and 950 Ohm (20x) tips.
RP4060
Power/Voltage Rail Probe. 4 GHz bandwidth, 1.2x attenuation, +/-60V offset, +/-800mV Includes a complete set of solder-in leads and coaxial cables. Browser tip sold seperately
RP2060
Power/Voltage Rail Probe. 2 GHz bandwidth, 1.2x attenuation, +/-60V offset, +/-800mV Includes a complete set of solder-in leads and coaxial cables. Browser tip sold seperately

High Voltage Optically Isolated Probes

HVFO100-1X-TIP-U
HVFO10X +/-1V (1x Attenuation) Universal Tip Accessory
HVFO100-5X-TIP-U
HVFO10X +/-5V (5x Attenuation) Universal Tip Accessory
HVFO100-10X-TIP-U
HVFO10X +/-10V (10x Attenuation) Universal Tip Accessory
HVFO100-20X-TIP-U
HVFO10X +/-20V (20x Attenuation) Universal Tip Accessory
HVFO100-40X-TIP-U
HVFO10X +/-40V (40x Attenuation) Universal Tip Accessory
HVFO108
High Voltage Fiber Optic Probe, 150 MHz Bandwidth. Includes soft-carrying case. Requires attenuating tip (ordered separately). Includes Qty. 1 1m Fiber Optic Cable.
DL10-ISO
High Voltage Optically Isolated Probe, 1 GHz Bandwidth. Includes soft-carrying case.
DL07-ISO
High Voltage Optically Isolated Probe, 700 MHz Bandwidth. Includes soft-carrying case.
DL03-ISO
High Voltage Optically Isolated Probe, 350 MHz Bandwidth. Includes soft-carrying case.
DL-ISO-2V-TIP
DL-ISO 2 Vpp MMCX Tip
DL-ISO-10V-TIP
DL-ISO 10 Vpp MMCX Tip
DL-ISO-40V-TIP
DL-ISO 40 Vpp MMCX Tip
DL-ISO-200V-TIP
DL-ISO 200 Vpp MMCX Tip
DL-ISO-1000V-TIP
DL-ISO 1000 Vpp Square Pin Tip
DL-ISO-2500V-TIP
DL-ISO 2500 Vpp Square Pin Tip
DL-ISO-ACC-KIT
DL-ISO series accessories kit Incl MMCX to Y-lead sockets/solder-ins, square pin socket/solder-ins, MMCX-sq pin adapter, grabbers

60 V Common Mode Differential Probes

DL05-HCM
500 MHz 60 V Common Mode Differential Probe. Includes standard set of leads and tips.
DL10-HCM
1 GHz 60 V Common Mode Differential Probe. Includes standard set of leads and tips.
DL-HCM-HiTemp
DL-HCM series high-temperature solder-in tip, 30 MHz bandwidth, 1 meter length.
DL-HCM-Acc-Kit
DL-HCM series accessories kit with probe holder, micro IC grabbers (Qty 2.), and Y-banana adaptor.
DL02-HCM